{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T07:04:55Z","timestamp":1788851095468,"version":"build-2803163510"},"reference-count":27,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2026,6,15]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Unintended device movement during carotid artery stenting (CAS) may lead to procedural complications. Our previous preliminary single-center study using a real-time artificial intelligence (AI) assistance system suggested that AI may help detect such movements and offer potential clinical usefulness; however, the small sample size limited the strength of the findings. In this multicenter study, we aimed to validate the accuracy and clinical utility of this real-time AI system in a diverse cohort.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 53 consecutive CAS procedures with distal filter protection were performed at three institutions under real-time AI monitoring. The AI system continuously analyzed fluoroscopic images and issued notifications when filter devices, guiding catheters, or guidewires moved outside predefined areas or went off-screen. Two types of distal filter protection devices were used. The participating institutions used two angiography systems. The efficacy, safety, and accuracy of the software were evaluated. Subgroup analyses were performed by filter type and operator experience.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>On average, there were 13.1 AI notifications per case, including 11.4 true positives and 1.7 false positives. The overall precision and recall were 87% and 98%, respectively. In 32% of true positive notifications, the operator adjusted the inappropriate device position after the notification. No significant differences were observed across filter types or operator experience. No AI-related complications were observed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This multicenter study demonstrated consistent performance of real-time AI-assisted notifications of device movement during CAS across multiple institutions and operators. The system showed high accuracy and supports its integration into standard neuroendovascular workflows.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2026-025520","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T17:20:48Z","timestamp":1782408048000},"page":"jnis-2026-025520","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Multicenter evaluation of real-time artificial intelligence assistance for carotid artery stenting"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2947-8812","authenticated-orcid":false,"given":"Yuya","family":"Sakakura","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, NTT Medical Center Tokyo, Shinagawa-ku, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryo","family":"Aiura","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0006-076X","authenticated-orcid":false,"given":"Kenichi","family":"Kono","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Fujigaoka Hospital, Yokohama, Kanagawa Prefecture, Japan"},{"name":"iMed Technologies, Bunkyo-ku, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3817-8918","authenticated-orcid":false,"given":"Yoshikazu","family":"Matsuda","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Saito Memorial Hospital, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasunobu","family":"Mitsura","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiro","family":"Sakaguchi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuya","family":"Higashizono","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9451-033X","authenticated-orcid":false,"given":"Hiroki","family":"Nagatsuka","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ikuya","family":"Natori","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7135-2220","authenticated-orcid":false,"given":"Yoichi","family":"Morofuji","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Showa Medical University Hospital, Shinagawa, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,6,25]]},"reference":[{"key":"2026062510203679000_jnis-2026-025520v1.1","doi-asserted-by":"crossref","DOI":"10.25259\/SNI_543_2020","article-title":"Preliminary study of eye tracking to investigate the differences in gaze behaviors depending on the experience of neuroendovascular therapy","volume":"11","author":"Shojima","year":"2020","journal-title":"Surg Neurol Int"},{"key":"2026062510203679000_jnis-2026-025520v1.2","doi-asserted-by":"crossref","first-page":"e827","DOI":"10.1016\/j.wneu.2020.05.012","article-title":"Preliminary Study of Eye-Tracking During the Coil Insertion Task in a Silastic Model of Intracranial Aneurysms","volume":"139","author":"Shojima","year":"2020","journal-title":"World Neurosurg"},{"key":"2026062510203679000_jnis-2026-025520v1.3","doi-asserted-by":"crossref","DOI":"10.5797\/jnet.ra.2024-0107","article-title":"Artificial Intelligence in Neuroendovascular Procedures","volume":"19","author":"Kono","year":"2025","journal-title":"J Neuroendovasc Ther"},{"key":"2026062510203679000_jnis-2026-025520v1.4","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-021873"},{"key":"2026062510203679000_jnis-2026-025520v1.5","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-022001"},{"key":"2026062510203679000_jnis-2026-025520v1.6","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A8704"},{"key":"2026062510203679000_jnis-2026-025520v1.7","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1227\/neu.0000000000003790","article-title":"Real-Time Artificial Intelligence-Assisted Middle Meningeal Artery Embolization Using Liquid Embolic Agents for Chronic Subdural Hematoma: A Preliminary Experience","volume":"99","author":"Kono","year":"2026","journal-title":"Neurosurgery"},{"key":"2026062510203679000_jnis-2026-025520v1.8","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2025-024452"},{"key":"2026062510203679000_jnis-2026-025520v1.9","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-021600"},{"key":"2026062510203679000_jnis-2026-025520v1.10","doi-asserted-by":"publisher","DOI":"10.1038\/bmt.2012.244"},{"key":"2026062510203679000_jnis-2026-025520v1.11","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2021.3102670"},{"key":"2026062510203679000_jnis-2026-025520v1.12","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2023-020300"},{"key":"2026062510203679000_jnis-2026-025520v1.13","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-021-02366-5"},{"key":"2026062510203679000_jnis-2026-025520v1.14","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1007\/s11548-017-1612-7","article-title":"Scale-space for empty catheter segmentation in PCI fluoroscopic images","volume":"12","author":"Bacchuwar","year":"2017","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026062510203679000_jnis-2026-025520v1.15","first-page":"2199","article-title":"Template-based balloon-marker and guidewire detection for coronary stents in cardiac fluoroscopy","volume":"2022","author":"Kotb","year":"2022","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"2026062510203679000_jnis-2026-025520v1.16","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1007\/s11548-018-1779-6","article-title":"Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair","volume":"13","author":"Breininger","year":"2018","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026062510203679000_jnis-2026-025520v1.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2021.101989"},{"key":"2026062510203679000_jnis-2026-025520v1.18","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1109\/THMS.2016.2545247","article-title":"Smoothness of surgical tool tip motion correlates to skill in endovascular tasks","volume":"46","author":"Estrada","year":"2016","journal-title":"IEEE Trans Hum Mach Syst"},{"key":"2026062510203679000_jnis-2026-025520v1.19","doi-asserted-by":"crossref","unstructured":"Murali B , Belvroy VM , Pandey S , et al . Towards automated performance assessment using velocity-based motion quality metrics. 2020 International Symposium on Medical Robotics (ISMR); Atlanta, GA, USA, 36\u201342. doi:10.1109\/ISMR48331.2020.9312946","DOI":"10.1109\/ISMR48331.2020.9312946"},{"key":"2026062510203679000_jnis-2026-025520v1.20","doi-asserted-by":"crossref","DOI":"10.5797\/jnet.oa.2025-0028","article-title":"World\u2019s First Artificial Intelligence-Based Evaluation of Rist Catheter Stability in Transradial Procedures: A Feasibility Study","volume":"19","author":"Tanoue","year":"2025","journal-title":"J Neuroendovasc Ther"},{"key":"2026062510203679000_jnis-2026-025520v1.21","doi-asserted-by":"crossref","first-page":"108930","DOI":"10.1016\/j.clineuro.2025.108930","article-title":"Novel artificial intelligence approach in neurointerventional practice: Preliminary findings on filter movement and ischemic lesions in carotid artery stenting","volume":"254","author":"Sagawa","year":"2025","journal-title":"Clin Neurol Neurosurg"},{"key":"2026062510203679000_jnis-2026-025520v1.22","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A7850"},{"key":"2026062510203679000_jnis-2026-025520v1.23","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2013-010774.rep","article-title":"Facial and neck hematoma after carotid artery stenting: an uncommon misadventure in endovascular carotid revascularization","volume":"6","author":"Grandhi","year":"2014","journal-title":"J Neurointerv Surg"},{"key":"2026062510203679000_jnis-2026-025520v1.24","doi-asserted-by":"publisher","DOI":"10.1177\/1971400915594928"},{"key":"2026062510203679000_jnis-2026-025520v1.25","doi-asserted-by":"crossref","DOI":"10.5812\/iranjradiol.28209","article-title":"Dissection of Extracranial Internal Carotid Artery Due to Balloon Guiding Catheter Resulting in Asymptomatic Internal Carotid Artery Occlusion","volume":"13","author":"Akpinar","year":"2016","journal-title":"Iran J Radiol"},{"key":"2026062510203679000_jnis-2026-025520v1.26","doi-asserted-by":"publisher","DOI":"10.1583\/06-1900.1"},{"key":"2026062510203679000_jnis-2026-025520v1.27","doi-asserted-by":"crossref","DOI":"10.3171\/FOC\/2008\/24\/2\/E12","article-title":"Iatrogenic vasospasm in carotid artery stent angioplasty with distal protection devices","volume":"24","author":"Schirmer","year":"2008","journal-title":"Neurosurg Focus"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2026-025520","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T17:20:51Z","timestamp":1782408051000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2026-025520"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,25]]},"references-count":27,"alternative-id":["10.1136\/jnis-2026-025520"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2026-025520","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,25]]}}}