{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T06:02:01Z","timestamp":1792735321271,"version":"4.5.0"},"reference-count":71,"publisher":"BMJ","funder":[{"name":"Society of Neurological Surgeons","award":["W81XWH2210740"],"award-info":[{"award-number":["W81XWH2210740"]}]},{"name":"Emory Department of Neurosurgery Catalyst Grant","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}]},{"name":"Emory Medical Care Foundation Research Grant","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2026,6,29]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Endovascular thrombectomy (EVT) is a cornerstone treatment for acute ischemic stroke (AIS) due to large vessel occlusion (LVO). Super large bore (SLB) catheters represent the latest evolution in device design for aspiration technology; however, their benefit over standard large bore (LB) catheters remains uncertain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A systematic literature search and proportional meta-analysis were conducted on studies reporting EVT outcomes with LB and SLB aspiration catheters. Both single-arm and comparative studies were included. The primary outcome was first-pass modified treatment in cerebral infarction (mTICI) score \u22652C (FPE2C). Secondary outcomes included safety and procedural measures. Random-effects models generated pooled estimates, with subgroup comparisons between LB and SLB and sensitivity analyses using leave-one-out and outlier exclusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 3966 patients (39 studies) were included in the primary analyses (SLB n=376; LB n=3590). FPE2C rates were similar between SLB and LB catheters (56% vs 50%; P=0.4). Final successful recanalization rates were high and similar in both groups (92% vs 92%; P=0.9). Procedural time did not differ, with pooled mean times of 27.03\u2009min for SLB and 26.97\u2009min for LB catheters. The need for rescue therapy showed a trend toward lower use with SLB compared with LB catheters (11% vs 20%; P=0.06). Rates of failure to reach the target clot showed a trend toward higher rates in the SLB group (10% vs 5%; P=0.11). Safety outcomes did not differ significantly (P&gt;0.2).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>SLB catheters did not demonstrate a clear advantage over LB catheters in reperfusion outcomes. Limited clinical data prevent conclusions on functional benefit, and further prospective studies are needed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2026-025524","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T17:20:28Z","timestamp":1784049628000},"page":"jnis-2026-025524","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Large bore versus super large bore aspiration catheters in mechanical thrombectomy: a systematic review and meta-analysis"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2005-5781","authenticated-orcid":false,"given":"Ariana","family":"Chacon","sequence":"first","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Layth JM","family":"Saada","sequence":"additional","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dareen","family":"Hijazi","sequence":"additional","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7868-5036","authenticated-orcid":false,"given":"Madhu","family":"Jatty","sequence":"additional","affiliation":[{"name":"Neurology, The University of Tennessee Health Science Center, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianwen","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Biostatistics and Bioinformatics, Emory University Rollins School of Public Health, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke","family":"Silveira","sequence":"additional","affiliation":[{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1979-2848","authenticated-orcid":false,"given":"Lucas","family":"Elijovich","sequence":"additional","affiliation":[{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Violiza","family":"Inoa-Acosta","sequence":"additional","affiliation":[{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Nickele","sequence":"additional","affiliation":[{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"},{"name":"Neurosurgery, Semmes-Murphey Neurologic and Spine Clinic, University of Tennessee Health Science Center, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9000-6083","authenticated-orcid":false,"given":"Ramesh","family":"Grandhi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Utah Health, Salt Lake City, Utah, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9134-0817","authenticated-orcid":false,"given":"Brian M","family":"Howard","sequence":"additional","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"},{"name":"Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1152-8826","authenticated-orcid":false,"given":"Jonathan A","family":"Grossberg","sequence":"additional","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"},{"name":"Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2601-8850","authenticated-orcid":false,"given":"Ali M","family":"Alawieh","sequence":"additional","affiliation":[{"name":"Neurosurgery, Emory University School of Medicine, Atlanta, Georgia, USA"},{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nitin","family":"Goyal","sequence":"additional","affiliation":[{"name":"Neurology, The University of Tennessee Health Science Center, Memphis, Tennessee, USA"},{"name":"Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,7,14]]},"reference":[{"key":"2026071410202157000_jnis-2026-025524v1.1","doi-asserted-by":"publisher","DOI":"10.1161\/cir.0000000000001303"},{"key":"2026071410202157000_jnis-2026-025524v1.2","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(16)00163-x"},{"key":"2026071410202157000_jnis-2026-025524v1.3","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.13647"},{"key":"2026071410202157000_jnis-2026-025524v1.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.11.052"},{"key":"2026071410202157000_jnis-2026-025524v1.5","doi-asserted-by":"crossref","unstructured":"Maier IL , Almallouhi E , Psychogios M , et al . Importance of First Pass Reperfusion in Endovascular Stroke Care \u2010 Insights From Thrombectomy and Aneurysm Registry (STAR). SVIN 2022;2. doi:10.1161\/SVIN.122.000346","DOI":"10.1161\/SVIN.122.000346"},{"key":"2026071410202157000_jnis-2026-025524v1.6","unstructured":"Alawieh AM , Elawady SS , Zohdy YM , et al . Prolonged intracranial catheter dwell time exacerbates penumbral stress and worsens stroke thrombectomy outcomes. J Neurointerv Surg 2024.:jnis-2024-02227."},{"key":"2026071410202157000_jnis-2026-025524v1.7","doi-asserted-by":"publisher","DOI":"10.1111\/ene.14490"},{"key":"2026071410202157000_jnis-2026-025524v1.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010713"},{"key":"2026071410202157000_jnis-2026-025524v1.9","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2022-019023"},{"key":"2026071410202157000_jnis-2026-025524v1.10","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1177\/15910199221138139","article-title":"Multicenter investigation of technical and clinical outcomes after thrombectomy for Proximal Medium Vessel Occlusion (pMeVO) by frontline technique","volume":"30","author":"Grossberg","year":"2024","journal-title":"Interv Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.11","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-021797"},{"key":"2026071410202157000_jnis-2026-025524v1.12","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/S0140-6736(19)30297-1","article-title":"Aspiration thrombectomy versus stent retriever thrombectomy as first-line approach for large vessel occlusion (COMPASS): a multicentre, randomised, open label, blinded outcome, non-inferiority trial","volume":"393","author":"Turk","year":"2019","journal-title":"The Lancet"},{"key":"2026071410202157000_jnis-2026-025524v1.13","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2017.9644"},{"key":"2026071410202157000_jnis-2026-025524v1.14","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1093\/neuros\/nyaa498","article-title":"Bigger is Still Better: A Step Forward in Reperfusion With React 71","volume":"88","author":"Gross","year":"2021","journal-title":"Neurosurgery"},{"key":"2026071410202157000_jnis-2026-025524v1.15","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1093\/neuros\/nyy444","article-title":"Lessons Learned Over More than 500 Stroke Thrombectomies Using ADAPT With Increasing Aspiration Catheter Size","volume":"86","author":"Alawieh","year":"2020","journal-title":"Neurosurgery"},{"key":"2026071410202157000_jnis-2026-025524v1.16","doi-asserted-by":"crossref","unstructured":"Dolia JN , Mohammaden MH , Tarek MA , et al . Structural Analysis of Aspiration Catheters and Procedural Outcomes: An Analysis of the SVIN Registry. SVIN 2024;4. doi:10.1161\/SVIN.123.001214","DOI":"10.1161\/SVIN.123.001214"},{"key":"2026071410202157000_jnis-2026-025524v1.17","doi-asserted-by":"crossref","unstructured":"Jazayeri SB , Reda A , Cortese J , et al . Impact of aspiration catheter inner diameter on first-pass effect: A systematic review and meta-analysis. Interv Neuroradiol 2025. doi:10.1177\/15910199251345637","DOI":"10.1177\/15910199251345637"},{"key":"2026071410202157000_jnis-2026-025524v1.18","doi-asserted-by":"crossref","unstructured":"Wodarg F , Brouwer P , Power S , et al . An in-vitro method for comparative analysis of aspiration catheter tracking performance. Interv Neuroradiol 2024.:15910199241278993. doi:10.1177\/15910199241278993","DOI":"10.1177\/15910199241278993"},{"key":"2026071410202157000_jnis-2026-025524v1.19","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.121.037904"},{"key":"2026071410202157000_jnis-2026-025524v1.20","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2022-018806"},{"key":"2026071410202157000_jnis-2026-025524v1.21","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2025-023096"},{"key":"2026071410202157000_jnis-2026-025524v1.22","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.125.051742"},{"key":"2026071410202157000_jnis-2026-025524v1.23","doi-asserted-by":"crossref","unstructured":"Jab\u0142o\u0144ska M , Ribo M . Super large bore catheters in the treatment of stroke: systematic review. J Neurointerv Surg 2026.:jnis-2026-025001. doi:10.1136\/jnis-2026-025001","DOI":"10.1136\/jnis-2026-025001"},{"key":"2026071410202157000_jnis-2026-025524v1.24","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"2026071410202157000_jnis-2026-025524v1.25","doi-asserted-by":"crossref","DOI":"10.1186\/s13643-016-0384-4","article-title":"Rayyan-a web and mobile app for systematic reviews","volume":"5","author":"Ouzzani","year":"2016","journal-title":"Syst Rev"},{"key":"2026071410202157000_jnis-2026-025524v1.26","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2025-023398"},{"key":"2026071410202157000_jnis-2026-025524v1.27","doi-asserted-by":"crossref","unstructured":"Campos JK , Meyer BM , Khan MW , et al . Feasibility of super-bore 0.088\u2033 mechanical thrombectomy in M1 vessels smaller than 8 French: Experience in 20 consecutive cases. Interv Neuroradiol 2024. doi:10.1177\/15910199241229198","DOI":"10.1177\/15910199241229198"},{"key":"2026071410202157000_jnis-2026-025524v1.28","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018318"},{"key":"2026071410202157000_jnis-2026-025524v1.29","unstructured":"National Heart L, and Blood Institute (NHLBI), National Heart L, and Blood Institute (NHLBI) . Study quality assessment tools. Bethesda (MD): National Institutes of Health. n.d. Available: https:\/\/www.nhlbi.nih.gov\/health-topics\/study-quality-assessment-tools"},{"key":"2026071410202157000_jnis-2026-025524v1.30","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s00234-018-2134-x","article-title":"A back and forth manual aspiration technique using a SOFIA Plus catheter for acute ischemic stroke: technical note","volume":"61","author":"O\u011fuz","year":"2019","journal-title":"Neuroradiology"},{"key":"2026071410202157000_jnis-2026-025524v1.31","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A6117"},{"key":"2026071410202157000_jnis-2026-025524v1.32","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000035864","article-title":"Application of Sofia Plus catheter tip shaping in the treatment of acute middle cerebral artery occlusion: A case control study","volume":"102","author":"Han","year":"2023","journal-title":"Medicine (Baltimore)"},{"key":"2026071410202157000_jnis-2026-025524v1.33","doi-asserted-by":"crossref","unstructured":"Ares WJ , Chowdhry S , Tonetti DA , et al . Aristotle\u2010Only Direct Aspiration First\u2010Pass Technique (AO\u2010ADAPT) for Endovascular Mechanical Thrombectomy: A Technical Series of a Novel Technique Demonstrating Safety and Efficacy. SVIN 2024;4. doi:10.1161\/SVIN.123.001069","DOI":"10.1161\/SVIN.123.001069"},{"key":"2026071410202157000_jnis-2026-025524v1.34","doi-asserted-by":"crossref","unstructured":"Ezzeldin R , Mir O , Delora A , et al . Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomy. J Neurointerv Surg 2025.:jnis-2025-024067. doi:10.1136\/jnis-2025-024067","DOI":"10.1136\/jnis-2025-024067"},{"key":"2026071410202157000_jnis-2026-025524v1.35","doi-asserted-by":"crossref","first-page":"e463","DOI":"10.1016\/j.wneu.2019.06.120","article-title":"Clinical Comparison of New Generation 0.071-inch and 0.072-inch Aspiration Catheters","volume":"130","author":"Gross","year":"2019","journal-title":"World Neurosurg"},{"key":"2026071410202157000_jnis-2026-025524v1.36","doi-asserted-by":"crossref","first-page":"e11","DOI":"10.1016\/j.wneu.2021.02.106","article-title":"Clinical Result of Mechanical Thrombectomy Using Sofia Plus with Acute Ischemic Stroke Compared with the Stent Retriever","volume":"149","author":"Tsuji","year":"2021","journal-title":"World Neurosurg"},{"key":"2026071410202157000_jnis-2026-025524v1.37","doi-asserted-by":"crossref","unstructured":"Ram\u00edrez-Torres M , Barrios AJ , Calleja Bonilla A , et al . Comparison between contact aspiration alone and combined thrombectomy for intracranial internal carotid artery occlusion: insights from SARA-3 registry. J Neurointerv Surg 2025.:jnis-2025-023955. doi:10.1136\/jnis-2025-023955","DOI":"10.1136\/jnis-2025-023955"},{"key":"2026071410202157000_jnis-2026-025524v1.38","doi-asserted-by":"crossref","first-page":"105566","DOI":"10.1016\/j.jstrokecerebrovasdis.2020.105566","article-title":"Comparison Between Three Commonly Used Large-Bore Aspiration Catheters in Terms of Successful Recanalization and First-Passage Effect","volume":"30","author":"Semeraro","year":"2021","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"2026071410202157000_jnis-2026-025524v1.39","doi-asserted-by":"crossref","DOI":"10.5797\/jnet.oa.2025-0099","article-title":"Contribution of Large Bore Aspiration Catheter to Mechanical Thrombectomy","volume":"19","author":"Inoue","year":"2025","journal-title":"J Neuroendovasc Ther"},{"key":"2026071410202157000_jnis-2026-025524v1.40","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1007\/s11604-021-01090-z","article-title":"Direct aspiration thrombectomy experience with the SOFIA 6F catheter in acute ischemic stroke","volume":"39","author":"Bilgin","year":"2021","journal-title":"Jpn J Radiol"},{"key":"2026071410202157000_jnis-2026-025524v1.41","article-title":"Factors Associated With Improved Technical Outcomes When Using 0.068- to 0.074-Inch Aspiration Catheters: Analysis From a Multicenter Retrospective Cohort","volume":"3","author":"Vargas","year":"2023","journal-title":"Stroke Vasc Interv Neurol"},{"key":"2026071410202157000_jnis-2026-025524v1.42","doi-asserted-by":"crossref","first-page":"241","DOI":"10.7461\/jcen.2022.E2021.12.002","article-title":"Forced suction thrombectomy in patients with acute ischemic stroke using the SOFIA Plus device","volume":"24","author":"Roh","year":"2022","journal-title":"J Cerebrovasc Endovasc Neurosurg"},{"key":"2026071410202157000_jnis-2026-025524v1.43","doi-asserted-by":"crossref","unstructured":"Alexander MD , Caldwell J , Lee SS , et al . FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions. Interv Neuroradiol 2024;15910199241284792. doi:10.1177\/15910199241284792","DOI":"10.1177\/15910199241284792"},{"key":"2026071410202157000_jnis-2026-025524v1.44","doi-asserted-by":"crossref","DOI":"10.1186\/s12883-026-04675-1","article-title":"Impact of balloon guiding catheter in contact aspiration thrombectomy using large bore aspiration catheter for acute anterior circulation stroke patients: a case-control study","volume":"26","author":"Kim","year":"2026","journal-title":"BMC Neurol"},{"key":"2026071410202157000_jnis-2026-025524v1.45","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1227\/neu.0000000000001937","article-title":"Impact of Increasing Aspiration Catheter Size and Refinement of Technique: Experience of Over 1000 Strokes Treated With ADAPT","volume":"91","author":"Al Kasab","year":"2022","journal-title":"Neurosurgery"},{"key":"2026071410202157000_jnis-2026-025524v1.46","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1177\/15910199231177754","article-title":"Improved catheter delivery for aspiration thrombectomy using Tenzing 7 ledge reducing catheter and FreeClimb 70","volume":"32","author":"Settecase","year":"2026","journal-title":"Interv Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.47","doi-asserted-by":"crossref","first-page":"545","DOI":"10.3340\/jkns.2019.0108","article-title":"Initial Experience of ACE68 Reperfusion Catheter in Patients with Acute Ischemic Stroke Related to Internal Carotid Artery Occlusion","volume":"62","author":"Jang","year":"2019","journal-title":"J Korean Neurosurg Soc"},{"key":"2026071410202157000_jnis-2026-025524v1.48","doi-asserted-by":"crossref","first-page":"30","DOI":"10.5469\/neuroint.2022.00479","article-title":"Initial Experience Using the New pHLO 0.072-inch Large-Bore Catheter for Direct Aspiration Thrombectomy in Acute Ischemic Stroke","volume":"18","author":"Leone","year":"2023","journal-title":"Neurointervention"},{"key":"2026071410202157000_jnis-2026-025524v1.49","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1177\/1591019919898923","article-title":"Initial experience with React 68 aspiration catheter","volume":"26","author":"Raymond","year":"2020","journal-title":"Interv Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.50","doi-asserted-by":"crossref","unstructured":"Bumanglag AV , Diehl D , Lee M , et al . Initial multicenter experience with the Broadway System for direct aspiration of large vessel occlusions in acute ischemic stroke. Interv Neuroradiol 2025.:15910199251394579. doi:10.1177\/15910199251394579","DOI":"10.1177\/15910199251394579"},{"key":"2026071410202157000_jnis-2026-025524v1.51","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1055\/s-0043-1761233","article-title":"Initial Results of a Direct Aspiration First-Pass Technique to Treat Acute Ischemic Stroke Patients in Nepal","volume":"18","author":"Phuyal","year":"2023","journal-title":"Asian J Neurosurg"},{"key":"2026071410202157000_jnis-2026-025524v1.52","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/s11547-022-01451-2","article-title":"JET 7 catheter for direct aspiration in carotid T occlusions: preliminary experience and literature review","volume":"127","author":"Romano","year":"2022","journal-title":"Radiol Med"},{"key":"2026071410202157000_jnis-2026-025524v1.53","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014633"},{"key":"2026071410202157000_jnis-2026-025524v1.54","doi-asserted-by":"crossref","unstructured":"Hassan AE , Haussen D , Al-Bayati A , et al . Millipede88 and Millipede70 catheters for contact aspiration thrombectomy in acute stroke: A multicenter experience. Interv Neuroradiol 2025. doi:10.1177\/15910199251350180","DOI":"10.1177\/15910199251350180"},{"key":"2026071410202157000_jnis-2026-025524v1.55","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012812"},{"key":"2026071410202157000_jnis-2026-025524v1.56","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2023-021407"},{"key":"2026071410202157000_jnis-2026-025524v1.57","doi-asserted-by":"crossref","DOI":"10.3389\/fneur.2024.1441810","article-title":"Safety and effectiveness of SOFIA\/SOFIA PLUS for direct aspiration as first line treatment in patients with acute anterior ischemic stroke: results from the prospective, multicentric SESAME study","volume":"15","author":"Neuberger","year":"2024","journal-title":"Front Neurol"},{"key":"2026071410202157000_jnis-2026-025524v1.58","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1093\/neuros\/nyx169","article-title":"Safety and Efficacy of the Sofia (6F) PLUS Distal Access Reperfusion Catheter in the Endovascular Treatment of Acute Ischemic Stroke","volume":"82","author":"Shallwani","year":"2018","journal-title":"Neurosurgery"},{"key":"2026071410202157000_jnis-2026-025524v1.59","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-021811"},{"key":"2026071410202157000_jnis-2026-025524v1.60","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1177\/15910199211005328","article-title":"SOFIA catheter for direct aspiration of large vessel occlusion stroke: A single-center cohort and meta-analysis","volume":"27","author":"Bolognini","year":"2021","journal-title":"Interv Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.61","doi-asserted-by":"crossref","DOI":"10.1186\/s12883-022-02784-1","article-title":"Technical note and first results on JET 7 thromboaspiration device for T-ICA occlusions","volume":"22","author":"Romano","year":"2022","journal-title":"BMC Neurol"},{"key":"2026071410202157000_jnis-2026-025524v1.62","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.jvir.2021.12.022","article-title":"Use of the Rocket Technique after Failure of the Direct Aspiration First-Pass Technique in Acute Stroke Thrombectomy","volume":"33","author":"Chau","year":"2022","journal-title":"J Vasc Interv Radiol"},{"key":"2026071410202157000_jnis-2026-025524v1.63","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1177\/1591019920942364","article-title":"Utilization of the large-bore Penumbra JET 7 reperfusion catheter in thrombectomy for acute ischemic stroke: A single-center experience","volume":"27","author":"Amireh","year":"2021","journal-title":"Interv Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.64","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.neurad.2022.02.007","article-title":"Experimental evaluation of the performance of large bore aspiration catheters","volume":"50","author":"Reymond","year":"2023","journal-title":"J Neuroradiol"},{"key":"2026071410202157000_jnis-2026-025524v1.65","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014929"},{"key":"2026071410202157000_jnis-2026-025524v1.66","doi-asserted-by":"crossref","unstructured":"Dhar V , Barrera PV , Akkipeddi SMK , et al . A single-center study of the RED 72 reperfusion catheter with SENDit technology in proximal large vessel occlusions. Interv Neuroradiol 2025.:15910199251358597. doi:10.1177\/15910199251358597","DOI":"10.1177\/15910199251358597"},{"key":"2026071410202157000_jnis-2026-025524v1.67","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2023-020792"},{"key":"2026071410202157000_jnis-2026-025524v1.68","unstructured":"Saad H , Koo AB , Grossberg JA , et al . Procedure duration predicts outcomes more than prehospital delay in endovascular stroke treatment. J Neurointerv Surg 2025."},{"key":"2026071410202157000_jnis-2026-025524v1.69","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-017316"},{"key":"2026071410202157000_jnis-2026-025524v1.70","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016459"},{"key":"2026071410202157000_jnis-2026-025524v1.71","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.118.023419"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2026-025524","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T17:20:33Z","timestamp":1784049633000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2026-025524"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,14]]},"references-count":71,"alternative-id":["10.1136\/jnis-2026-025524"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2026-025524","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,14]]}}}