{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T17:49:35Z","timestamp":1782236975679,"version":"3.54.5"},"reference-count":16,"publisher":"BMJ","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2026,6,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Intracranial catheter navigation relies on haptic cues interpreted as resistance. However, resistance perception is subjective, limiting standardized training. Prior studies measured forces at the proximal device end, but vessel-wall deformation during catheter advancement has not been synchronized with expert resistance judgment. In this feasibility study, outer-wall strain was used as a relative index of wall deformation in a tortuous vascular phantom.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Six board-certified neurointerventionalists, each performing one navigation trial, advanced a 0.021 inch microcatheter over a 0.014 inch microguidewire through a tortuous vascular phantom with nine sequential bends, eight instrumented with outer-wall strain gauges. Operators reported mild resistance and unacceptable resistance, defined as resistance beyond which advancement was judged unsafe in this phantom. Vessel strain was recorded continuously without real-time feedback.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In this phantom, when mild resistance was first reported, maximum strain among instrumented gauges reached 410.8\u00b1102.9 \u00b5\u03b5, localized approximately two bends proximal to the catheter tip, on average. At unacceptable resistance, maximum strain increased to 850.3\u00b1219.8 \u00b5\u03b5 at the most proximal gauge. Peak strain location shifted proximally as perceived resistance escalated, and further distal tip advancement ceased. Strain at unacceptable resistance consistently exceeded that at mild resistance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In this phantom, expert resistance perception was associated with reproducible vessel-wall strain patterns. Because microstrain values are model-specific, they should be viewed as relative deformation indices, not patient-applicable thresholds or measures of in vivo wall stress. Linking subjective resistance to quantifiable wall deformation may support objective assessment of resistance perception and proficiency-based simulation training, pending validation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2026-025559","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T17:21:00Z","timestamp":1782235260000},"page":"jnis-2026-025559","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Quantifying expert resistance perception from vessel wall deformation in intracranial catheter navigation"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6899-0878","authenticated-orcid":false,"given":"Takeshi","family":"Uno","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Teikyo University School of Medicine, Itabashi, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4388-151X","authenticated-orcid":false,"given":"Masaaki","family":"Shojima","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Teikyo University School of Medicine, Itabashi, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8571-6400","authenticated-orcid":false,"given":"Makoto","family":"Ohta","sequence":"additional","affiliation":[{"name":"Institute of Fluid Science, Tohoku University, Sendai, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Kosukegawa","sequence":"additional","affiliation":[{"name":"Institute of Fluid Science, Tohoku University, Sendai, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6274-1216","authenticated-orcid":false,"given":"Yuta","family":"Oyama","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Teikyo University School of Medicine, Itabashi, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riko","family":"Hasegawa","sequence":"additional","affiliation":[{"name":"Institute of Fluid Science, Tohoku University, Sendai, Japan"},{"name":"Graduate School of Engineering, Tohoku University, Sendai, Miyagi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayami","family":"Omiya","sequence":"additional","affiliation":[{"name":"Institute of Fluid Science, Tohoku University, Sendai, Japan"},{"name":"Graduate School of Biomedical Engineering, Tohoku University, Sendai, Miyagi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichi","family":"Haga","sequence":"additional","affiliation":[{"name":"Graduate School of Biomedical Engineering, Tohoku University, Sendai, Miyagi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Shin","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Teikyo University School of Medicine, Itabashi, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,6,23]]},"reference":[{"key":"2026062310203271000_jnis-2026-025559v1.1","first-page":"1706","article-title":"Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: a meta-analysis","volume":"23","author":"Cloft","year":"2002","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026062310203271000_jnis-2026-025559v1.2","first-page":"319","article-title":"Management of vascular perforations that occur during neurointerventional procedures","volume":"12","author":"Halbach","year":"1991","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026062310203271000_jnis-2026-025559v1.3","doi-asserted-by":"crossref","unstructured":"Gravino G . Haptic feedback in robotic endovascular neurosurgical intervention: a necessity or a commodity? Interv Neuroradiol 2025. doi:10.1177\/15910199241304851","DOI":"10.1177\/15910199241304851"},{"key":"2026062310203271000_jnis-2026-025559v1.4","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1007\/s10439-017-1791-y","article-title":"Objective Assessment of Endovascular Navigation Skills with Force Sensing","volume":"45","author":"Rafii-Tari","year":"2017","journal-title":"Ann Biomed Eng"},{"key":"2026062310203271000_jnis-2026-025559v1.5","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.wneu.2017.06.092","article-title":"Clinical Application of Insertion Force Sensor System for Coil Embolization of Intracranial Aneurysms","volume":"105","author":"Matsubara","year":"2017","journal-title":"World Neurosurg"},{"key":"2026062310203271000_jnis-2026-025559v1.6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2007.01.016"},{"key":"2026062310203271000_jnis-2026-025559v1.7","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.jvs.2011.01.058","article-title":"The importance of expert feedback during endovascular simulator training","volume":"54","author":"Boyle","year":"2011","journal-title":"J Vasc Surg"},{"key":"2026062310203271000_jnis-2026-025559v1.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.05.041"},{"key":"2026062310203271000_jnis-2026-025559v1.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014468"},{"key":"2026062310203271000_jnis-2026-025559v1.10","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.20965\/jrm.2022.p1297","article-title":"Development of a Force Sensor for a Neuroendovascular Intervention Support Robot System","volume":"34","author":"Tadauchi","year":"2022","journal-title":"JRM Journal of Robotics and Mechatronics"},{"key":"2026062310203271000_jnis-2026-025559v1.11","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2024-021477"},{"key":"2026062310203271000_jnis-2026-025559v1.12","doi-asserted-by":"crossref","first-page":"2669","DOI":"10.1021\/acsaelm.0c00538","article-title":"Miniaturized Piezo Force Sensor for a Medical Catheter and Implantable Device","volume":"2","author":"Gil","year":"2020","journal-title":"ACS Appl Electron Mater"},{"key":"2026062310203271000_jnis-2026-025559v1.13","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1299\/jfst.3.533","article-title":"Measurements of Dynamic Viscoelasticity of Poly (vinyl alcohol) Hydrogel for the Development of Blood Vessel Biomodeling","volume":"3","author":"Kosukegawa","year":"2008","journal-title":"JFST Journal of Fluid Science and Technology"},{"key":"2026062310203271000_jnis-2026-025559v1.14","doi-asserted-by":"crossref","first-page":"225","DOI":"10.3233\/THC-2004-12302","article-title":"Poly-vinyl alcohol hydrogel vascular models for in vitro aneurysm simulations: the key to low friction surfaces","volume":"12","author":"Ohta","year":"2004","journal-title":"Technol Health Care"},{"key":"2026062310203271000_jnis-2026-025559v1.15","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.triboint.2005.10.010","article-title":"Contact and friction between catheter and blood vessel","volume":"40","author":"Takashima","year":"2007","journal-title":"Tribol Int"},{"key":"2026062310203271000_jnis-2026-025559v1.16","doi-asserted-by":"crossref","first-page":"3018","DOI":"10.1016\/j.jbiomech.2014.06.042","article-title":"Curvature effect on hemodynamic conditions at the inner bend of the carotid siphon and its relation to aneurysm formation","volume":"47","author":"Lauric","year":"2014","journal-title":"J Biomech"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2026-025559","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T17:21:04Z","timestamp":1782235264000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2026-025559"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,23]]},"references-count":16,"alternative-id":["10.1136\/jnis-2026-025559"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2026-025559","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,23]]}}}