{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T17:40:44Z","timestamp":1786642844241,"version":"build-2736575974"},"reference-count":30,"publisher":"BMJ","license":[{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2026,7,23]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Flat-detector computed tomography (FDCT) is increasingly used for peri-interventional cerebral imaging but is associated with a relatively high radiation exposure. Copper (Cu) filtration may reduce radiation dose. However, its impact on cerebral image quality and intracranial hemorrhage detection remains unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this retrospective single-center study, 31 patients undergoing neurointerventional procedures with intraindividual FDCT acquisitions with and without Cu filtration were analyzed. Quantitative image quality was assessed using contrast-to-noise ratio (CNR). Qualitative image analysis and intracranial hemorrhage detection were independently evaluated by two readers blinded to Cu filtration status using five-point scales.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Cu filtration resulted in a significant radiation dose reduction of 25.9% for both entrance skin dose (145.19\u00b113.18\u2009mGy vs 195.89\u00b118.05\u2009mGy) and dose-area product (41.52\u00b13.77\u2009Gy\u00b7cm\u00b2 vs 56.01\u00b15.16\u2009Gy\u00b7cm\u00b2), respectively (P&lt;0.001). No differences in CNR were observed for unfiltered vs Cu-filtered FDCT (basal ganglia: 4.73\u00b12.04 vs 4.37\u00b11.99, P=0.419). Qualitative image ratings were similar between techniques (supratentorial cortex: 2.27\u00b10.66 vs 2.08\u00b10.75, P=0.089), with very good inter-reader agreement (\u03ba=0.86; 95%\u2009CI: 0.80 to 0.91). All intracranial hemorrhages were correctly identified by both techniques. Correct exclusion of intracranial hemorrhage was 15\/16 with Cu filtration and 14\/16 without Cu filtration, without statistically significant difference. Differences were limited to hemorrhage mimics (n=2) and minor variations in diagnostic confidence without affecting binary classification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Cu filtration in cerebral FDCT enables substantial radiation dose reduction while preserving image quality and intracranial hemorrhage detection, supporting its clinical implementation as a practical dose optimization strategy for peri-interventional imaging.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/jnis-2026-025750","type":"journal-article","created":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:20:21Z","timestamp":1786036821000},"page":"jnis-2026-025750","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Copper filtration reduces radiation dose while maintaining image quality in cerebral flat-detector CT"],"prefix":"10.1136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2509-5459","authenticated-orcid":false,"given":"Niclas","family":"Schmitt","sequence":"first","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Hilgenfeld","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8992-4757","authenticated-orcid":false,"given":"Dominik F","family":"Vollherbst","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3436-9298","authenticated-orcid":false,"given":"Christoph M","family":"Mooshage","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian","family":"Preisner","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9980-2390","authenticated-orcid":false,"given":"Michael O","family":"Breckwoldt","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Hubert","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Schwarz","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kianush","family":"Karimian-Jazi","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomislav","family":"Stavrovski","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9223-9662","authenticated-orcid":false,"given":"Christian","family":"Herweh","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Bendszus","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus A","family":"M\u00f6hlenbruch","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lena","family":"Wucherpfennig","sequence":"additional","affiliation":[{"name":"Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany"},{"name":"Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"key":"2026081310201022000_jnis-2026-025750v2.1","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012866"},{"key":"2026081310201022000_jnis-2026-025750v2.2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5595"},{"key":"2026081310201022000_jnis-2026-025750v2.3","first-page":"330","article-title":"The utility of DynaCT in neuroendovascular procedures","volume":"27","author":"Heran","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026081310201022000_jnis-2026-025750v2.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018018"},{"key":"2026081310201022000_jnis-2026-025750v2.5","doi-asserted-by":"publisher","DOI":"10.1177\/1747493019895655"},{"key":"2026081310201022000_jnis-2026-025750v2.6","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2086"},{"key":"2026081310201022000_jnis-2026-025750v2.7","article-title":"Flat-panel cone-beam CT in the clinic: history and current state","volume":"8","author":"Fahrig","year":"2021","journal-title":"J Med Imaging (Bellingham)"},{"key":"2026081310201022000_jnis-2026-025750v2.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2021-018312"},{"key":"2026081310201022000_jnis-2026-025750v2.9","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-017-0574-z"},{"key":"2026081310201022000_jnis-2026-025750v2.10","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.117.018077"},{"key":"2026081310201022000_jnis-2026-025750v2.11","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1111\/jon.13098","article-title":"Flat\u2010panel detector CT to assess intracranial hemorrhage immediately following mechanical thrombectomy","volume":"33","author":"Inoa","year":"2023","journal-title":"Journal of Neuroimaging"},{"key":"2026081310201022000_jnis-2026-025750v2.12","doi-asserted-by":"publisher","DOI":"10.3171\/2010.2.JNS091054"},{"key":"2026081310201022000_jnis-2026-025750v2.13","doi-asserted-by":"crossref","DOI":"10.1186\/s41747-023-00412-2","article-title":"Sine Spin flat detector CT can improve cerebral soft tissue imaging: a retrospective in vivo study","volume":"8","author":"Schmitt","year":"2024","journal-title":"Eur Radiol Exp"},{"key":"2026081310201022000_jnis-2026-025750v2.14","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-022-01172-z"},{"key":"2026081310201022000_jnis-2026-025750v2.15","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5568"},{"key":"2026081310201022000_jnis-2026-025750v2.16","first-page":"1898","article-title":"3D cerebral angiography: radiation dose comparison with digital subtraction angiography","volume":"26","author":"Schueler","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026081310201022000_jnis-2026-025750v2.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2009.12.015"},{"key":"2026081310201022000_jnis-2026-025750v2.18","doi-asserted-by":"crossref","first-page":"198","DOI":"10.4103\/0971-6203.170790","article-title":"Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography\/computed tomography","volume":"40","author":"Rana","year":"2015","journal-title":"J Med Phys"},{"key":"2026081310201022000_jnis-2026-025750v2.19","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.radi.2023.03.005","article-title":"Potentials of additional copper filtration on radiation dose and image quality for adults underwent digital chest X-ray imaging in Dubai Health Authority - UAE","volume":"29","author":"Siraj","year":"2023","journal-title":"Radiography (Lond)"},{"key":"2026081310201022000_jnis-2026-025750v2.20","doi-asserted-by":"crossref","unstructured":"Tugwell-Allsup JR , Morris RW , Thomas K , et al . Neonatal digital chest radiography\u2013 should we be using additional copper filtration? Br J Radiol 2022;95. doi:10.1259\/bjr.20211026","DOI":"10.1259\/bjr.20211026"},{"key":"2026081310201022000_jnis-2026-025750v2.21","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/RLI.0000000000001235","article-title":"Effect of Copper Filtration on Radiation Dose in Cerebral Three-dimensional Rotational Angiography During Endovascular Aneurysm Treatment","volume":"61","author":"Schmitt","year":"2025","journal-title":"Invest Radiol"},{"key":"2026081310201022000_jnis-2026-025750v2.22","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2372041738"},{"key":"2026081310201022000_jnis-2026-025750v2.23","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.ejmp.2020.11.022","article-title":"X-ray dose reduction using additional copper filtration for dental cone beam CT","volume":"81","author":"Kuramoto","year":"2021","journal-title":"Phys Med"},{"key":"2026081310201022000_jnis-2026-025750v2.24","doi-asserted-by":"publisher","DOI":"10.1177\/001316446002000104"},{"key":"2026081310201022000_jnis-2026-025750v2.25","doi-asserted-by":"crossref","unstructured":"Altman DG . Practical statistics for medical research. CRC press, 1990.","DOI":"10.1201\/9780429258589"},{"key":"2026081310201022000_jnis-2026-025750v2.26","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/j.crad.2018.05.019","article-title":"Cataract risk of neuro-interventional procedures: a nationwide population-based matched-cohort study","volume":"73","author":"Cheng","year":"2018","journal-title":"Clin Radiol"},{"key":"2026081310201022000_jnis-2026-025750v2.27","doi-asserted-by":"publisher","DOI":"10.1177\/0146645314562321"},{"key":"2026081310201022000_jnis-2026-025750v2.28","doi-asserted-by":"publisher","DOI":"10.1038\/s41591-023-02620-0"},{"key":"2026081310201022000_jnis-2026-025750v2.29","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000120726.69501.74"},{"key":"2026081310201022000_jnis-2026-025750v2.30","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0b013e31828406de"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/jnis-2026-025750","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T17:20:21Z","timestamp":1786641621000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/jnis-2026-025750"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,6]]},"references-count":30,"alternative-id":["10.1136\/jnis-2026-025750"],"URL":"https:\/\/doi.org\/10.1136\/jnis-2026-025750","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,6]]}}}