{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T04:04:48Z","timestamp":1784865888920,"version":"3.55.0"},"reference-count":12,"publisher":"BMJ","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2012,3,22]]},"published-print":{"date-parts":[[2013,7]]},"abstract":"<jats:p>Flow-diverting devices offer an exciting alternative for the management of large and giant intracranial aneurysms. However, the risk and mechanism of delayed aneurysmal rupture and hemorrhage following placement of these devices are not clearly understood. Two patients with similar symptomatic giant paraclinoid internal carotid artery aneurysms are described. Both patients were treated with SILK flow-diverting devices. In both patients the SILK device was placed without technical complication. The first patient continued to do well 1\u2005year postoperatively with complete aneurysm occlusion. The second patient had a delayed subarachnoid hemorrhage despite markedly decreased filling of the aneurysm immediately following the procedure. Flow-diverting devices are an exciting technology which provide an alternative treatment modality in the management of giant intracranial aneurysms. However, caution must be exercised as the risks of delayed complications have yet to be fully elucidated. Similar aneurysms may have drastically different outcomes due to the unpredictability of this technology.<\/jats:p>","DOI":"10.1136\/neurintsurg-2012-010316","type":"journal-article","created":{"date-parts":[[2012,4,17]],"date-time":"2012-04-17T21:56:33Z","timestamp":1334699793000},"page":"e23-e23","source":"Crossref","is-referenced-by-count":13,"title":["Flow diverters and a tale of two aneurysms"],"prefix":"10.1136","volume":"5","author":[{"given":"Gregory A","family":"Kuzmik","sequence":"first","affiliation":[{"name":"Yale University School of Medicine, New Haven, Connecticut, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa","family":"Williamson","sequence":"additional","affiliation":[{"name":"Yale University School of Medicine, New Haven, Connecticut, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asiri","family":"Ediriwickrema","sequence":"additional","affiliation":[{"name":"Yale University School of Medicine, New Haven, Connecticut, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Andeejani","sequence":"additional","affiliation":[{"name":"Department of Radiology and Imaging, Riyadh Military Hospital, Riyadh, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ketan R","family":"Bulsara","sequence":"additional","affiliation":[{"name":"Yale University School of Medicine, New Haven, Connecticut, USA"},{"name":"Department of Neurosurgery, Yale University School of Medicine, New Haven, Connecticut, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2012,4,17]]},"reference":[{"key":"2025092911271110000_5.4.e23.1","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000339109.98070.65"},{"key":"2025092911271110000_5.4.e23.2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2421"},{"key":"2025092911271110000_5.4.e23.3","doi-asserted-by":"crossref","unstructured":"Fischer S Vajda Z Aguilar Perez M . Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology. Published Online First: 1 September 2011. doi:10.1007\/s00234-011-0948-x","DOI":"10.1007\/s00234-011-0948-x"},{"key":"2025092911271110000_5.4.e23.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2011.03.050"},{"key":"2025092911271110000_5.4.e23.5","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0012492"},{"key":"2025092911271110000_5.4.e23.6","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.110.589911"},{"key":"2025092911271110000_5.4.e23.7","doi-asserted-by":"crossref","unstructured":"Wagner A Cortsen M Hauerberg J . Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent. Neuroradiology. Published Online First: 6 September 2011. doi:10.1007\/s00234-011-0949-9.","DOI":"10.1007\/s00234-011-0949-9"},{"key":"2025092911271110000_5.4.e23.8","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2398"},{"key":"2025092911271110000_5.4.e23.9","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000325497.79690.4C"},{"key":"2025092911271110000_5.4.e23.10","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-010-0676-7"},{"key":"2025092911271110000_5.4.e23.11","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2370"},{"key":"2025092911271110000_5.4.e23.12","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1148\/radiol.2273020530","article-title":"Differentiation of white, mixed, and red thrombi: value of CT in estimation of the prognosis of thrombolysis phantom study","volume":"228","author":"Kirchhof","year":"2003","journal-title":"Radiology"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2012-010316","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T18:27:20Z","timestamp":1759170440000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2012-010316"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,17]]},"references-count":12,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2013,6,11]]},"published-print":{"date-parts":[[2013,7]]}},"alternative-id":["10.1136\/neurintsurg-2012-010316"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2012-010316","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4,17]]}}}