{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T20:39:41Z","timestamp":1793133581818,"version":"4.5.0"},"reference-count":24,"publisher":"BMJ","issue":"6","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2014,4,10]]},"published-print":{"date-parts":[[2015,6]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Artificial stroke models can be used for testing various thrombectomy devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>To determine the value of combined stentriever\u2013aspiration thrombectomy compared with the stentriever-alone approach.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We designed an in vitro model of the intracranial circulation with a focus on the middle cerebral artery (MCA) that closely resembles the human intracranial circulation. After introducing fresh clot in the MCA, we used conventional biplane angiography and microangiographic fluoroscopy to compare recanalization rates and occurrence of emboli in new, unaffected territory for thrombectomy approaches in which a stentriever (Solitaire flow restoration stentriever, Covidien) was used alone or in combination with continuous manual aspiration through a Navien catheter (Covidien).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In a total of 22 experiments (11 for each approach), successful clot delivery to the MCA was achieved in all cases. Successful angiographic recanalization (thrombolysis in cerebral infarction score of 2b\u20133) was achieved more frequently with the combined stentriever\u2013aspiration approach than with the stentriever-alone approach (in 10 vs 4 experiments, p=0.023). Emboli in new territory occurred in three experiments with the stentriever-alone approach, and none were seen with the combined approach (p=0.21).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The combined stentriever\u2013aspiration approach to thrombectomy leads to better angiographic recanalization rates than use of the stentriever alone. Further experiments are needed to test the value of balloon-guide catheters and aspiration performed using other types of catheters and modes of aspiration.<\/jats:p><\/jats:sec>","DOI":"10.1136\/neurintsurg-2014-011148","type":"journal-article","created":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T09:32:29Z","timestamp":1398936749000},"page":"453-457","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":67,"title":["Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison"],"prefix":"10.1136","volume":"7","author":[{"given":"Maxim","family":"Mokin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ciprian N","family":"Ionita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swetadri Vasan","family":"Setlur Nagesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Rudin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elad I","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adnan H","family":"Siddiqui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2014,4,30]]},"reference":[{"key":"2024052301065715000_7.6.453.1","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1136\/neurintsurg-2012-010624.rep","article-title":"Aspiration thrombectomy in concert with stent thrombectomy","volume":"6","author":"Dumont","year":"2013","journal-title":"J Neurointerv Surg"},{"key":"2024052301065715000_7.6.453.2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010986"},{"key":"2024052301065715000_7.6.453.3","doi-asserted-by":"publisher","DOI":"10.1227\/01.neu.0000429859.96652.57"},{"key":"2024052301065715000_7.6.453.4","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.002407"},{"key":"2024052301065715000_7.6.453.5","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.670463"},{"key":"2024052301065715000_7.6.453.6","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3103"},{"key":"2024052301065715000_7.6.453.7","doi-asserted-by":"crossref","unstructured":"Simon S Grey CP Massenzo T . Exploring the efficacy of cyclic vs static aspiration in a cerebral thrombectomy model: an initial proof of concept study. J Neurointerv Surg 2013 Mar 26. [Epub ahead of print]. doi: 10.1136\/neurintsurg-2012-010638.","DOI":"10.1136\/neurintsurg-2013-010941"},{"key":"2024052301065715000_7.6.453.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010638"},{"key":"2024052301065715000_7.6.453.9","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.001972"},{"key":"2024052301065715000_7.6.453.10","unstructured":"Autodesk, Inc. MeshMixer. http:\/\/www.meshmixer.com\/ (accessed 24 Jan 2014)."},{"key":"2024052301065715000_7.6.453.11","first-page":"1357","article-title":"A dedicated animal model for mechanical thrombectomy in acute stroke","volume":"27","author":"Gralla","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"2024052301065715000_7.6.453.12","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.jneumeth.2012.09.006","article-title":"Embolic middle cerebral artery occlusion model using thrombin and fibrinogen composed clots in rat","volume":"211","author":"Ren","year":"2012","journal-title":"J Neurosci Methods"},{"key":"2024052301065715000_7.6.453.13","doi-asserted-by":"crossref","first-page":"4112","DOI":"10.1118\/1.3599751","article-title":"A theoretical and experimental evaluation of the microangiographic fluoroscope: a high-resolution region-of-interest X-ray imager","volume":"38","author":"Jain","year":"2011","journal-title":"Med Phys"},{"key":"2024052301065715000_7.6.453.14","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1227\/NEU.0b013e3182299814","article-title":"Use of the microangiographic fluoroscope for coiling of intracranial aneurysms","volume":"69","author":"Binning","year":"2011","journal-title":"Neurosurgery"},{"key":"2024052301065715000_7.6.453.15","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010435"},{"key":"2024052301065715000_7.6.453.16","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2011-010101"},{"key":"2024052301065715000_7.6.453.17","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s10143-014-0518-x","article-title":"Silicone models as basic training and research aid in endovascular neurointervention-a single-center experience and review of the literature","volume":"37","author":"Paramasivam","year":"2014","journal-title":"Neurosurg Rev"},{"key":"2024052301065715000_7.6.453.18","doi-asserted-by":"publisher","DOI":"10.2176\/nmc.45.567"},{"key":"2024052301065715000_7.6.453.19","first-page":"3792","article-title":"Mechanical properties of human coronary arteries","volume":"2010","author":"Claes","year":"2010","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"2024052301065715000_7.6.453.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2009.07.009"},{"key":"2024052301065715000_7.6.453.21","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010895"},{"key":"2024052301065715000_7.6.453.22","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010616"},{"key":"2024052301065715000_7.6.453.23","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-011024"},{"key":"2024052301065715000_7.6.453.24","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-011022"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2014-011148","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T09:55:50Z","timestamp":1716458150000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2014-011148"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,30]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2015,5,14]]},"published-print":{"date-parts":[[2015,6]]}},"alternative-id":["10.1136\/neurintsurg-2014-011148"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2014-011148","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,30]]}}}