{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T01:45:53Z","timestamp":1792374353083,"version":"4.4.0"},"reference-count":8,"publisher":"BMJ","issue":"10","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2014,8,11]]},"published-print":{"date-parts":[[2015,10]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Deconstructive approaches may be necessary to treat a variety of neurovascular pathologies. Recently, a new device has become available for endovascular arterial occlusion that may have unique applications in neurovascular disease. The Micro Vascular Plug (MVP, Reverse Medical, Irvine, California, USA) has been designed for vessel occlusion through targeted embolization.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To report the results from our initial experience with eight consecutive patients in whom the MVP was used to achieve endovascular occlusion of an artery in the head and neck.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Eight consecutive patients treated over a nine-month period were included. The patients\u2019 radiographic and electronic medical records were retrospectively reviewed. Specifically demographic information, clinical indication, site of arterial occlusion, size of MVP, time to vessel occlusion, clinical complications, use of other secondary embolic agents, and clinical outcome were recorded. Follow-up information when available is presented.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The MVP was used in eight patients for the treatment of neurovascular disease. Indications for treatment included post-traumatic head\/neck bleeding (n=3), carotid\u2013cavernous fistula (1), vertebral\u2013vertebral fistula (1), giant fusiform vertebral aneurysm (1), stump-emboli after carotid dissection (1), and iatrogenic vertebral artery penetrating injury (1). One device was used in five patients, two in two patients, and one patient with extensive vertebral\u2013vertebral venous fistula required three plugs to effectively trap the fistula from proximal and distal aspects. Vessel occlusion was obtained in &lt;2\u2005min in each case and there were no procedural complications. Four patients were followed up and no incidence of plug migration or vessel recanalization was seen.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>To the best of our knowledge, this is the first series reporting the use of MVP in neurovascular disease. Use of this device may be associated with shorter procedural times and cost savings in comparison with the use of microcoils for vessel occlusion. Our experience shows that MVP can have unique applications in neurovascular pathologies and it complements other occlusive devices.<\/jats:p><\/jats:sec>","DOI":"10.1136\/neurintsurg-2014-011306","type":"journal-article","created":{"date-parts":[[2014,8,29]],"date-time":"2014-08-29T07:18:32Z","timestamp":1409296712000},"page":"758-761","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":21,"title":["Micro Vascular Plug (MVP)-assisted vessel occlusion in neurovascular pathologies: technical results and initial clinical experience"],"prefix":"10.1136","volume":"7","author":[{"given":"Narlin B","family":"Beaty","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaurav","family":"Jindal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dheeraj","family":"Gandhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2014,8,28]]},"reference":[{"key":"2024052301163375000_7.10.758.1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1987.66.1.0040"},{"key":"2024052301163375000_7.10.758.2","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-199501000-00002"},{"key":"2024052301163375000_7.10.758.3","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-199502000-00001"},{"key":"2024052301163375000_7.10.758.4","first-page":"649","article-title":"Balloon occlusion of the carotid artery prior to surgery for neck tumors","volume":"11","author":"Gonzales","year":"1990","journal-title":"AJNR Am J Neuroradiol"},{"key":"2024052301163375000_7.10.758.5","first-page":"1201","article-title":"Endovascular occlusion of the carotid or vertebral artery with temporary proximal flow arrest and microcoils: clinical results","volume":"18","author":"Graves","year":"1997","journal-title":"AJNR Am J Neuroradiol"},{"key":"2024052301163375000_7.10.758.6","unstructured":"Instructions for Use MVP\u00ae Micro Vascular Plug. Reverse Medical\u2122. http:\/\/reversemed.com\/pdf\/mvp_us_inst.pdf (10 Oct 2011)."},{"key":"2024052301163375000_7.10.758.7","doi-asserted-by":"crossref","first-page":"S74","DOI":"10.1227\/NEU.0000000000000176","article-title":"Endovascular advances for brain arteriovenous malformations","volume":"74","author":"Crowley","year":"2014","journal-title":"Neurosurgery"},{"key":"2024052301163375000_7.10.758.8","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1007\/s00270-012-0387-z","article-title":"The AMPLATZER Vascular Plug: a review of the device and its clinical applications","volume":"35","author":"Wang","year":"2012","journal-title":"Cardiovasc Intervent Radiology"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2014-011306","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T10:13:56Z","timestamp":1716459236000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2014-011306"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8,28]]},"references-count":8,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2015,9,13]]},"published-print":{"date-parts":[[2015,10]]}},"alternative-id":["10.1136\/neurintsurg-2014-011306"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2014-011306","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8,28]]}}}