{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T12:55:45Z","timestamp":1783774545825,"version":"3.55.0"},"reference-count":24,"publisher":"BMJ","issue":"2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2014,12,12]]},"published-print":{"date-parts":[[2016,2]]},"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>The PulseRider is a novel device intended for use in the treatment of aneurysms arising at bifurcations. We present the initial results of the first three cases in the USA employing the PulseRider device.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Aneurysms intended to be treated with the PulseRider device at a single institution were identified prospectively. Aneurysms arising at either the carotid terminus or basilar apex that were relatively broad-necked were considered candidates for treatment with the novel device.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Patients were pretreated with dual antiplatelet therapy. All cases were performed under general endotracheal anesthesia. An appropriately sized PulseRider device was deployed across the neck of the aneurysm. A microcatheter was then navigated over a 0.014\u2005inch microwire through the device into the aneurysm. Complete occlusion of the aneurysm was achieved in all cases without intraprocedural complications.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>We have found in our early experience with the Pulse Rider device that its use is safe and effective as an adjunct in the treatment of bifurcation aneurysms arising at the basilar apex or carotid terminus. As such, it represents a useful addition to the armamentarium of the neuroendovascular specialist.<\/jats:p><\/jats:sec>","DOI":"10.1136\/neurintsurg-2014-011531","type":"journal-article","created":{"date-parts":[[2015,1,6]],"date-time":"2015-01-06T02:11:00Z","timestamp":1420510260000},"page":"186-189","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":40,"title":["Initial experience with the PulseRider for the treatment of bifurcation aneurysms: report of first three cases in the USA"],"prefix":"10.1136","volume":"8","author":[{"given":"Alejandro M","family":"Spiotta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Imran","family":"Chaudry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aquilla S","family":"Turk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond D","family":"Turner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2015,1,5]]},"reference":[{"key":"2024052302145053000_8.2.186.1","doi-asserted-by":"publisher","DOI":"10.1053\/jscd.2002.130390"},{"key":"2024052302145053000_8.2.186.2","doi-asserted-by":"publisher","DOI":"10.3171\/2011.8.JNS101767"},{"key":"2024052302145053000_8.2.186.3","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-200008000-00022"},{"key":"2024052302145053000_8.2.186.4","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000097194.35781.EA"},{"key":"2024052302145053000_8.2.186.5","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199909000-00024"},{"key":"2024052302145053000_8.2.186.6","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-200006000-00022"},{"key":"2024052302145053000_8.2.186.7","first-page":"30","article-title":"[Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases]","volume":"24","author":"Moret","year":"1997","journal-title":"J Neuroradiol"},{"key":"2024052302145053000_8.2.186.8","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2212010474"},{"key":"2024052302145053000_8.2.186.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010312"},{"key":"2024052302145053000_8.2.186.10","first-page":"509","article-title":"A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique","volume":"25","author":"Chow","year":"2004","journal-title":". AJNR Am J Neuroradiol"},{"key":"2024052302145053000_8.2.186.11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1177\/159101991101700107","article-title":"Y-stent-assisted coil embolization of wide-neck intracranial aneurysms. A single center experience","volume":"17","author":"Akgul","year":"2011","journal-title":"Intervent Neuroradiol"},{"key":"2024052302145053000_8.2.186.12","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2475"},{"key":"2024052302145053000_8.2.186.13","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e318271ebfc"},{"issue":"(2 Suppl Operative)","key":"2024052302145053000_8.2.186.14","first-page":"244","article-title":"Nonoverlapping Y-configuration stenting technique with dual closed-cell stents in wide-neck basilar tip aneurysms","volume":"70","author":"Cho","year":"2012","journal-title":"Neurosurgery"},{"key":"2024052302145053000_8.2.186.15","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2011-010086"},{"key":"2024052302145053000_8.2.186.16","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000015"},{"key":"2024052302145053000_8.2.186.17","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1177\/159101991201800206","article-title":"Y-stent-assisted coil embolization of anterior circulation aneurysms using two Solitaire AB devices: a single center experience","volume":"18","author":"Martinez-Galdamez","year":"2012","journal-title":"Intervent Neuroradiol"},{"key":"2024052302145053000_8.2.186.18","first-page":"91","article-title":"Y-stent-assisted coil embolisation of wide-necked aneurysms using a new fully retrievable and detachable intracranial stent: report of two cases","volume":"18","author":"Muda","year":"2011","journal-title":"Malays J Med Sci"},{"key":"2024052302145053000_8.2.186.19","doi-asserted-by":"publisher","DOI":"10.1179\/016164104225013969"},{"key":"2024052302145053000_8.2.186.20","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-009-0603-y"},{"key":"2024052302145053000_8.2.186.21","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000163684.75204.CD"},{"key":"2024052302145053000_8.2.186.22","first-page":"762389","article-title":"Y-stenting for bifurcation aneurysm coil embolization: what is the risk?","volume":"2014","author":"Spiotta","year":"2014","journal-title":"Stroke Res Treat"},{"key":"2024052302145053000_8.2.186.23","first-page":"1035","article-title":"Y-configured dual intracranial stent-assisted coil embolization for the treatment of wide-necked basilar tip aneurysms","volume":"56","author":"Thorell","year":"2005","journal-title":"Neurosurgery"},{"key":"2024052302145053000_8.2.186.24","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2961"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2014-011531","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T10:40:33Z","timestamp":1716460833000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2014-011531"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1,5]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,1,13]]},"published-print":{"date-parts":[[2016,2]]}},"alternative-id":["10.1136\/neurintsurg-2014-011531"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2014-011531","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,1,5]]}}}