{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T16:25:50Z","timestamp":1772727950975,"version":"3.50.1"},"reference-count":32,"publisher":"BMJ","issue":"7","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2017,12,8]]},"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>The LVIS Blue is an FDA-approved stent with 28% metallic coverage that is indicated for use in conjunction with coil embolization for the treatment of intracranial aneurysms. Given a porosity similar to approved flow diverters and higher than currently available intracranial stents, we sought to evaluate the effectiveness of this device for the treatment of intracranial aneurysms.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We performed an observational single-center study to evaluate initial occlusion and occlusion at 6-month follow-up for patients treated with the LVIS Blue in conjunction with coil embolization at our institution using the modified Raymond\u2013Roy classification (mRRC), where mRRC 1 indicates complete embolization, mRRC 2 persistent opacification of the aneurysm neck, mRRC 3a filling of the aneurysm dome within coil interstices, and mRRC 3b filling of the aneurysm dome.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Sixteen aneurysms were treated with the LVIS Blue device in conjunction with coil embolization with 6-month angiographic follow-up. Aneurysms were treated throughout the intracranial circulation: five proximal internal carotid artery (ICA) (ophthalmic or communicating segments), two superior cerebellar artery, two ICA terminus, two anterior communicating artery, two distal middle cerebral artery, one posterior inferior cerebellar artery, and two basilar tip aneurysms. Post-procedurally, there was one mRRC 1 closure, five mRRC 2 closures, and 10 mRRC 3a or 3b occlusion. At follow-up, all the mRRC 1 and mRRC 3a closures, 85% of the mRRC 3b closures and 75% of the mRRC 2 closures were stable or improved to an mRRC 1 or 2 at follow-up.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The LVIS Blue represents a safe option as a coil adjunct for endovascular embolization within both the proximal and distal anterior and posterior circulation.<\/jats:p><\/jats:sec>","DOI":"10.1136\/neurintsurg-2017-013608","type":"journal-article","created":{"date-parts":[[2018,1,14]],"date-time":"2018-01-14T01:20:22Z","timestamp":1515892822000},"page":"686-690","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":13,"title":["LVIS Blue as a low porosity stent and coil adjuvant"],"prefix":"10.1136","volume":"10","author":[{"given":"Matthew J","family":"Koch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher J","family":"Stapleton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott B","family":"Raymond","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susan","family":"Williams","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thabele M","family":"Leslie-Mazwi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James David","family":"Rabinov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aman B","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2018,1,13]]},"reference":[{"key":"2025032703260538000_10.7.686.1","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000159645.86823.AF"},{"key":"2025032703260538000_10.7.686.2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3574"},{"key":"2025032703260538000_10.7.686.3","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.620328"},{"key":"2025032703260538000_10.7.686.4","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13120099"},{"key":"2025032703260538000_10.7.686.5","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2023"},{"key":"2025032703260538000_10.7.686.6","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000339109.98070.65"},{"key":"2025032703260538000_10.7.686.7","doi-asserted-by":"publisher","DOI":"10.1186\/s12967-016-0959-9"},{"key":"2025032703260538000_10.7.686.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011229"},{"key":"2025032703260538000_10.7.686.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2015-012035"},{"key":"2025032703260538000_10.7.686.10","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011258"},{"key":"2025032703260538000_10.7.686.11","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2012-010455a.24"},{"key":"2025032703260538000_10.7.686.12","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.neurad.2012.11.001","article-title":"Combined use of a double-lumen remodeling balloon and a low-profile stent in the treatment of intracranial aneurysms (\u2018remostent\u2019 technique): a technical note","volume":"40","author":"Kadziolka","year":"2013","journal-title":"Neuroradiology"},{"key":"2025032703260538000_10.7.686.13","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-011-0948-x"},{"key":"2025032703260538000_10.7.686.14","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012946"},{"key":"2025032703260538000_10.7.686.15","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1227\/NEU.0000000000001377","article-title":"Pipeline embolization device for small intracranial aneurysms: evaluation of safety and efficacy in a multicenter cohort","volume":"80","author":"Griessenauer","year":"2017","journal-title":"Neurosurgery"},{"key":"2025032703260538000_10.7.686.16","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-014-1345-z"},{"key":"2025032703260538000_10.7.686.17","doi-asserted-by":"publisher","DOI":"10.3171\/2008.7.JNS08322"},{"key":"2025032703260538000_10.7.686.18","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-014-1363-x"},{"key":"2025032703260538000_10.7.686.19","doi-asserted-by":"crossref","unstructured":"Adeeb N , Griessenauer CJ , Patel AS , et al . The use of single stent-assisted coiling in treatment of bifurcation aneurysms: a multicenter cohort study with proposal of a scoring system to predict complete occlusion. Neurosurgery 2017.doi:10.1093\/neuros\/nyx310","DOI":"10.1093\/neuros\/nyx310"},{"key":"2025032703260538000_10.7.686.20","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e31825c36dd"},{"key":"2025032703260538000_10.7.686.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.06.127"},{"key":"2025032703260538000_10.7.686.22","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e3182181c2b"},{"key":"2025032703260538000_10.7.686.23","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.109.558114"},{"key":"2025032703260538000_10.7.686.24","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0155062","article-title":"Large residual volume, not low packing density, is the most influential risk factor for recanalization after coil embolization of cerebral aneurysms","volume":"11","author":"Sadato","year":"2016","journal-title":"PLoS One"},{"key":"2025032703260538000_10.7.686.25","doi-asserted-by":"publisher","DOI":"10.3171\/2012.2.JNS111942"},{"key":"2025032703260538000_10.7.686.26","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e31821723f2"},{"key":"2025032703260538000_10.7.686.27","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e31828ba984"},{"key":"2025032703260538000_10.7.686.28","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e318258e1f8"},{"key":"2025032703260538000_10.7.686.29","doi-asserted-by":"publisher","DOI":"10.3171\/2017.3.FOCUS16427"},{"key":"2025032703260538000_10.7.686.30","doi-asserted-by":"crossref","unstructured":"Matsuda Y , Chung J , Keigher K , et al . A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies. J Neurointerv Surg 2017:neurintsurg-2017-013074 (Epub ahead of print).doi:10.1136\/neurintsurg-2017-013074","DOI":"10.1136\/neurintsurg-2017-013074"},{"key":"2025032703260538000_10.7.686.31","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e318214abbd"},{"key":"2025032703260538000_10.7.686.32","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3166"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2017-013608","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T10:34:18Z","timestamp":1743071658000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2017-013608"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,13]]},"references-count":32,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2018,6,14]]},"published-print":{"date-parts":[[2018,7]]}},"alternative-id":["10.1136\/neurintsurg-2017-013608"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2017-013608","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,13]]}}}