{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T12:55:46Z","timestamp":1783774546647,"version":"3.55.0"},"reference-count":30,"publisher":"BMJ","issue":"4","funder":[{"name":"the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2018,8,13]]},"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Little has been reported about the feasibility and durability of a Low-profile Visualized Intraluminal Support Junior (LVIS Jr) Y-stenting device for wide-neck bifurcation aneurysms.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Purpose<\/jats:title>\n                  <jats:p>To evaluate the feasibility and durability of LVIS Jr Y-stenting for coiling of unruptured wide-neck bifurcation aneurysms.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>We identified patients in whom LVIS Jr Y-stenting was attempted for unruptured wide-neck bifurcation aneurysms from a prospectively maintained registry of a referral hospital. Procedural success rate, treatment-related morbidity, and clinical and angiographic outcomes were retrospectively assessed.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>LVIS Jr Y-stenting was attempted for a total of 21 aneurysms in 21 patients (mean age 60\u00b18.9 years; M:F=6:15): nine basilar artery, six anterior communicating artery, four middle cerebral artery, one internal carotid artery, and one vertebrobasilar fenestration aneurysms. The mean dome and neck size were 7.9\u00b12.7\u2009mm and 5.7\u00b11.8\u2009mm, respectively. All attempts were successful. Treatment-related morbidity occurred in one individual with a modified Rankin Scale (mRS) score of 2. Immediate postprocedural angiograms showed complete occlusion in 15 (71.4%) and neck remnant in 6 (28.6%) patients. All 21 patients had good outcomes (mRS score 0\u20132) for a mean of 12 months' follow-up (range 6\u201327 months); mRS score 0 in 20 patients and mRS score 2 in one patient, respectively. Follow-up imaging over a mean of 11 months (range 6\u201318 months) was available in 18 patients (85.7%). All aneurysms showed complete occlusion at follow-up.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>LVIS Jr Y-stenting and coiling for wide-neck bifurcation aneurysms seems to be feasible with acceptable safety and to provide durable aneurysm occlusion for wide-neck bifurcation aneurysms.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/neurintsurg-2018-014128","type":"journal-article","created":{"date-parts":[[2018,8,30]],"date-time":"2018-08-30T12:22:04Z","timestamp":1535631724000},"page":"400-404","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":20,"title":["Y-configuration stenting for coiling of wide-neck bifurcation aneurysms using Low-profile Visualized Intraluminal Support Junior"],"prefix":"10.1136","volume":"11","author":[{"given":"Keun Young","family":"Park","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Severance Hospital Stroke Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Moon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Severance Hospital Stroke Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Joon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Severance Hospital Stroke Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joonho","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Severance Hospital Stroke Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Whan","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Severance Hospital Stroke Center, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,8,30]]},"reference":[{"key":"2025092911403008000_11.4.400.1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000073841.88563.E9"},{"key":"2025092911403008000_11.4.400.2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3032"},{"key":"2025092911403008000_11.4.400.3","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3166"},{"key":"2025092911403008000_11.4.400.4","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e318214abbd"},{"key":"2025092911403008000_11.4.400.5","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000015"},{"key":"2025092911403008000_11.4.400.6","doi-asserted-by":"publisher","DOI":"10.7461\/jcen.2016.18.4.355"},{"key":"2025092911403008000_11.4.400.7","article-title":"Treatment of a middle cerebral artery bifurcation aneurysm using a double neuroform stent \"Y\" configuration and coil embolization: technical case report","volume":"57","author":"Sani","year":"2005","journal-title":"Neurosurgery"},{"key":"2025092911403008000_11.4.400.8","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-009-0603-y"},{"key":"2025092911403008000_11.4.400.9","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-014-1345-z"},{"key":"2025092911403008000_11.4.400.10","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2013-010818"},{"key":"2025092911403008000_11.4.400.11","doi-asserted-by":"publisher","DOI":"10.1177\/1591019918759307"},{"key":"2025092911403008000_11.4.400.12","doi-asserted-by":"publisher","DOI":"10.1161\/hs0901.095600"},{"key":"2025092911403008000_11.4.400.13","article-title":"\"Cross-over\" technique for horizontal stenting of an internal carotid bifurcation aneurysm using a new self-expandable stent: technical case report","volume":"58(1 Suppl)","author":"Benndorf","year":"2006","journal-title":"Neurosurgery"},{"key":"2025092911403008000_11.4.400.14","first-page":"ONS-258","article-title":"Intra\/extra-aneurysmal stent placement for management of complex and wide-necked- bifurcation aneurysms: eight cases using the waffle cone technique","volume":"58(4 Suppl 2)","author":"Horowitz","year":"2006","journal-title":"Neurosurgery"},{"key":"2025092911403008000_11.4.400.15","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2010.02.004"},{"key":"2025092911403008000_11.4.400.16","first-page":"509","article-title":"A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique","volume":"25","author":"Chow","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025092911403008000_11.4.400.17","doi-asserted-by":"publisher","DOI":"10.5469\/neuroint.2011.6.2.53"},{"key":"2025092911403008000_11.4.400.18","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-014-2163-0"},{"key":"2025092911403008000_11.4.400.19","doi-asserted-by":"publisher","DOI":"10.1179\/016164104225013969"},{"key":"2025092911403008000_11.4.400.20","first-page":"1035","article-title":"Y-configured dual intracranial stent-assisted coil embolization for the treatment of wide-necked basilar tip aneurysms","volume":"56","author":"Thorell","year":"2005","journal-title":"Neurosurgery"},{"key":"2025092911403008000_11.4.400.21","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-004-1304-1"},{"key":"2025092911403008000_11.4.400.22","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-009-0436-9"},{"key":"2025092911403008000_11.4.400.23","doi-asserted-by":"publisher","DOI":"10.1177\/159101991101700107"},{"key":"2025092911403008000_11.4.400.24","first-page":"ons244","article-title":"Nonoverlapping Y-configuration stenting technique with dual closed-cell stents in wide-neck basilar tip aneurysms","volume":"70(Suppl)","author":"Cho","year":"2012","journal-title":"Neurosurgery"},{"key":"2025092911403008000_11.4.400.25","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2961"},{"key":"2025092911403008000_11.4.400.26","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e318265a416"},{"key":"2025092911403008000_11.4.400.27","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1007\/s00701-013-1771-4","article-title":"Triple antiplatelet therapy with addition of cilostazol to aspirin and clopidogrel for Y-stent-assisted coil embolization of cerebral aneurysms","volume":"155","author":"Kono","year":"2013","journal-title":"Acta Neurochir"},{"key":"2025092911403008000_11.4.400.28","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1080\/01616412.2017.1398881","article-title":"A new low-profile visualized intraluminal support (LVIS) device, LVIS Blue: laboratory comparison between old and new LVIS","volume":"40","author":"Chung","year":"2018","journal-title":"Neurol Res"},{"key":"2025092911403008000_11.4.400.29","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-014-1363-x"},{"key":"2025092911403008000_11.4.400.30","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2475"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2018-014128","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T18:40:41Z","timestamp":1759171241000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2018-014128"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,30]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,3,19]]},"published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1136\/neurintsurg-2018-014128"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2018-014128","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,30]]}}}