{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T05:23:17Z","timestamp":1791523397426,"version":"4.3.4"},"reference-count":64,"publisher":"BMJ","issue":"1","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2020,9,10]]},"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:p>Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the past decades. The technological advances have been driven by the experience that coils fail to completely exclude all IAs from the blood circulation, the need to treat the diseased parent vessel segment leading to the aneurysm formation, and expansion of endovascular therapy to treat more complex IAs. Stents were initially developed to support the placement of coils inside wide neck aneurysms. However, early work on stent-like tubular braided structure led to a more sophisticated construct that then later was coined as a flow diverter (FD) and found its way into clinical application. Although FDs were initially used to treat wide-neck large and giant internal carotid artery aneurysms only amenable to surgical trap with or without a bypass or endovascular vessel sacrifice, its use in other types of IAs and cerebrovascular pathology promptly followed. Lately, we have witnessed an explosion in the application of FDs and subsequently their modifications leading to their ubiquitous use in endovascular therapy. In this review we aim to compile the available FD technology, evaluate the devices\u2019 peculiarities from the authors\u2019 perspective, and analyze the current literature to support initial and expanded indications, recognizing that this may be outdated soon.<\/jats:p>","DOI":"10.1136\/neurintsurg-2020-015877","type":"journal-article","created":{"date-parts":[[2020,9,25]],"date-time":"2020-09-25T17:20:29Z","timestamp":1601054429000},"page":"54-62","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":167,"title":["Review of current intracranial aneurysm flow diversion technology and clinical use"],"prefix":"10.1136","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3744-7845","authenticated-orcid":false,"given":"Sudeepta","family":"Dandapat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Mendez-Ruiz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8024-4712","authenticated-orcid":false,"given":"Mario","family":"Mart\u00ednez-Gald\u00e1mez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Macho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahram","family":"Derakhshani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gustavo","family":"Foa Torres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vitor M","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anil","family":"Arat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay K","family":"Wakhloo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3744-7845","authenticated-orcid":false,"given":"Santiago","family":"Ortega-Gutierrez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2020,9,25]]},"reference":[{"key":"2024052305491574000_13.1.54.1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1991.75.1.0008"},{"key":"2024052305491574000_13.1.54.2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(05)67214-5"},{"key":"2024052305491574000_13.1.54.3","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp-2016-315433"},{"key":"2024052305491574000_13.1.54.4","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000073841.88563.E9"},{"key":"2024052305491574000_13.1.54.5","doi-asserted-by":"publisher","DOI":"10.1115\/1.2800773"},{"key":"2024052305491574000_13.1.54.6","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199808000-00126"},{"key":"2024052305491574000_13.1.54.7","unstructured":"Wakhloo AK , Lieber BB . The beginnings of flow diversion: a historical review. In: Park M , Taussky P , Albuquerque FC , et al , eds. Flow diversion of cerebral aneurysms. New York: Thieme, 2018."},{"key":"2024052305491574000_13.1.54.8","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000392"},{"key":"2024052305491574000_13.1.54.9","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.108.533760"},{"key":"2024052305491574000_13.1.54.10","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.110.595066"},{"key":"2024052305491574000_13.1.54.11","doi-asserted-by":"publisher","DOI":"10.1007\/BF02684187"},{"key":"2024052305491574000_13.1.54.12","doi-asserted-by":"publisher","DOI":"10.1115\/1.2796081"},{"key":"2024052305491574000_13.1.54.13","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-015-1230-1"},{"key":"2024052305491574000_13.1.54.14","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5973"},{"key":"2024052305491574000_13.1.54.15","doi-asserted-by":"publisher","DOI":"10.1136\/jnis.2009.000083"},{"key":"2024052305491574000_13.1.54.16","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2016-012669","article-title":"In situ tissue engineering: endothelial growth patterns as a function of flow diverter design","volume":"9","author":"Marosfoi","year":"2017","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.17","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.106.479576"},{"key":"2024052305491574000_13.1.54.18","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4411"},{"key":"2024052305491574000_13.1.54.19","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2019-014765","article-title":"Predictive value of platelet reactivity unit (PRU) value for thrombotic and hemorrhagic events during flow diversion procedures: a meta-analysis","volume":"11","author":"Ajadi","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.20","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.116.015308"},{"key":"2024052305491574000_13.1.54.21","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1159\/000496702","article-title":"Platelet function testing in neurovascular procedures: tool or gimmick?","volume":"8","author":"Cheung","year":"2019","journal-title":"Intervent Neurol"},{"key":"2024052305491574000_13.1.54.22","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2421"},{"key":"2024052305491574000_13.1.54.23","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyw014"},{"key":"2024052305491574000_13.1.54.24","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13120099"},{"key":"2024052305491574000_13.1.54.25","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4111"},{"key":"2024052305491574000_13.1.54.26","doi-asserted-by":"publisher","DOI":"10.1159\/000446503"},{"key":"2024052305491574000_13.1.54.27","doi-asserted-by":"crossref","first-page":"E402","DOI":"10.1093\/neuros\/nyy422","article-title":"Multicenter study of pipeline flex for intracranial aneurysms","volume":"84","author":"Brasiliense","year":"2019","journal-title":"Neurosurgery"},{"key":"2024052305491574000_13.1.54.28","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015091"},{"key":"2024052305491574000_13.1.54.29","doi-asserted-by":"crossref","first-page":"3195","DOI":"10.1002\/jbm.a.36514","article-title":"Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model","volume":"106","author":"Girdhar","year":"2018","journal-title":"J Biomed Mater Res A"},{"key":"2024052305491574000_13.1.54.30","article-title":"Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study","author":"Rice","year":"2020","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.31","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1093\/neuros\/nyz356","article-title":"Safety and effectiveness of the Pipeline Flex Embolization Device with Shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study","volume":"87","author":"Trivelato","year":"2019","journal-title":"Neurosurgery"},{"key":"2024052305491574000_13.1.54.32","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.000434"},{"key":"2024052305491574000_13.1.54.33","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4078"},{"key":"2024052305491574000_13.1.54.34","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1161\/STROKEAHA.118.024135","article-title":"SCENT trial","volume":"50","author":"Meyers","year":"2019","journal-title":"Stroke"},{"key":"2024052305491574000_13.1.54.35","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2019-015734","article-title":"First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerations","author":"Orru","year":"2020","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.36","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5592"},{"key":"2024052305491574000_13.1.54.37","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2018-014261","article-title":"SAFE study (safety and efficacy analysis of FRED embolic device in aneurysm treatment): 1-year clinical and anatomical results","volume":"11","author":"Pierot","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.38","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5332"},{"key":"2024052305491574000_13.1.54.39","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyw123"},{"key":"2024052305491574000_13.1.54.40","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.110.589911"},{"key":"2024052305491574000_13.1.54.41","doi-asserted-by":"publisher","DOI":"10.1177\/1591019918771340"},{"key":"2024052305491574000_13.1.54.42","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4143"},{"key":"2024052305491574000_13.1.54.43","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014770"},{"key":"2024052305491574000_13.1.54.44","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2019-014840","article-title":"Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent","volume":"11","author":"Schob","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.45","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012502"},{"key":"2024052305491574000_13.1.54.46","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-017-1786-2"},{"key":"2024052305491574000_13.1.54.47","article-title":"The p48MW flow diverter-initial human experience","author":"Bhogal","year":"2019","journal-title":"Clin Neuroradiol"},{"key":"2024052305491574000_13.1.54.48","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1007\/s00270-018-2036-7","article-title":"Hydrophilic stent coating inhibits platelet adhesion on stent surfaces: initial results in vitro","volume":"41","author":"Lenz-Habijan","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2024052305491574000_13.1.54.49","doi-asserted-by":"crossref","DOI":"10.1177\/0300060519879580","article-title":"The p48_HPC antithrombogenic flow diverter: initial human experience using single antiplatelet therapy","volume":"48","author":"Bhogal","year":"2020","journal-title":"J Int Med Res"},{"key":"2024052305491574000_13.1.54.50","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2018-014166","article-title":"Safety and efficacy of the Derivo embolization device for the treatment of ruptured intracranial aneurysms","volume":"11","author":"Goertz","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"2024052305491574000_13.1.54.51","doi-asserted-by":"crossref","first-page":"2351","DOI":"10.1161\/STROKEAHA.119.025407","article-title":"Derivo embolization device for the treatment of intracranial aneurysms","volume":"50","author":"Trivelato","year":"2019","journal-title":"Stroke"},{"key":"2024052305491574000_13.1.54.52","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3925"},{"key":"2024052305491574000_13.1.54.53","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1159\/000495074","article-title":"Safety and efficacy of the Pipeline Embolization Device use in the outside circle of Willis located intracranial aneurysms: a single-center experience","volume":"8","author":"Al Kasab","year":"2020","journal-title":"Interv Neurol"},{"key":"2024052305491574000_13.1.54.54","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014631"},{"key":"2024052305491574000_13.1.54.55","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A6002"},{"key":"2024052305491574000_13.1.54.56","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4807"},{"key":"2024052305491574000_13.1.54.57","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5730"},{"key":"2024052305491574000_13.1.54.58","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014363"},{"key":"2024052305491574000_13.1.54.59","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1007\/s00270-020-02418-4","article-title":"The p48 flow modulation device with hydrophilic polymer coating (HPC) for the treatment of acutely ruptured aneurysms: early clinical experience using single antiplatelet therapy","volume":"43","author":"Aguilar-Perez","year":"2020","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2024052305491574000_13.1.54.60","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyy076"},{"key":"2024052305491574000_13.1.54.61","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5029"},{"key":"2024052305491574000_13.1.54.62","doi-asserted-by":"publisher","DOI":"10.3171\/2015.6.JNS1565"},{"key":"2024052305491574000_13.1.54.63","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1007\/s00062-016-0511-6","article-title":"Direct carotid cavernous sinus fistulae: vessel reconstruction using flow-diverting implants","volume":"27","author":"Wendl","year":"2017","journal-title":"Clin Neuroradiol"},{"key":"2024052305491574000_13.1.54.64","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014731"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2020-015877","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T08:49:34Z","timestamp":1716454174000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2020-015877"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,25]]},"references-count":64,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12,15]]},"published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1136\/neurintsurg-2020-015877"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2020-015877","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,25]]}}}