{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T16:54:02Z","timestamp":1781801642906,"version":"3.54.5"},"reference-count":13,"publisher":"BMJ","issue":"4","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2020,11,7]]},"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Intraoperative neuromonitoring (IONM) is often used during cerebral endovascular procedures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>To investigate the relationship between intraoperative vascular complications and IONM signal changes, and the impact of interventions on signal resolution and postoperative outcomes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A series of 2278 cerebral endovascular procedures conducted under general anesthesia and using electroencephalography and somatosensory evoked potential monitoring were retrospectively reviewed. A subset of 763 procedures also included motor evoked potentials (MEPs). IONM alerts were categorized as either a partial attenuation or complete loss of signal. Vascular complications were subcategorized as due to rupture, emboli, instrumentation, or vasospasm. Odds ratios (ORs) for new postoperative motor deficits were calculated and diagnostic accuracy was measured using sensitivity, specificity, and likelihood ratios.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The overall incidence of new postoperative motor deficit was 1.2%; 20.4% in cases with an IONM alert and 0.09% in cases without an alert. Relative to procedures with no alerts, odds of a new deficit increased if there was partial signal attenuation (OR=210.9, 95% CI 44.3 to 1003.5, p&lt;0.0001) and increased further with complete loss of signal (OR=1437.3, 95% CI 297.3 to 6948.2, p&lt;0.0001). Relative to procedures with unresolved alerts, odds of a new deficit decreased if the alert was fully resolved (OR=0.039, 95% CI 0.005 to 0.306, p&lt;0.002). Procedures using MEPs had slightly higher sensitivity (92.3% vs 85.7%) but slightly lower specificity (96.7% vs 98.2%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>An IONM alert associated with an arterial complication is associated with a dramatic increase in odds of a new postoperative deficit; however, if there is resolution of the alert prior to closure, odds of a new deficit decrease significantly.<\/jats:p><\/jats:sec>","DOI":"10.1136\/neurintsurg-2020-016604","type":"journal-article","created":{"date-parts":[[2020,12,23]],"date-time":"2020-12-23T18:20:55Z","timestamp":1608747655000},"page":"378-383","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":19,"title":["Intraoperative vascular complications during 2278 cerebral endovascular procedures with multimodality IONM: relationship between signal change, complication, intervention and postoperative outcome"],"prefix":"10.1136","volume":"13","author":[{"given":"W Bryan","family":"Wilent","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olga","family":"Belyakina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Korsgaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1054-9414","authenticated-orcid":false,"given":"Stavropoula I","family":"Tjoumakaris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Reid","family":"Gooch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1544-4910","authenticated-orcid":false,"given":"Pascal","family":"Jabbour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Rosenwasser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joey D","family":"English","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Warren","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Tesdahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Cohen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony K","family":"Sestokas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2020,12,22]]},"reference":[{"key":"2024111104061190000_13.4.378.1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2006.105.5.675"},{"key":"2024111104061190000_13.4.378.2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3017"},{"key":"2024111104061190000_13.4.378.3","first-page":"1520","article-title":"Neurophysiological monitoring in the endovascular therapy of aneurysms","volume":"24","author":"Liu","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"2024111104061190000_13.4.378.4","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1227\/NEU.0000000000000510","article-title":"Somatosensory evoked potential changes in neuroendovascular procedures: incidence and association with clinical outcome in 873 patients","volume":"75","author":"Phillips","year":"2014","journal-title":"Neurosurgery"},{"key":"2024111104061190000_13.4.378.5","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1093\/ons\/opx104","article-title":"Diagnostic accuracy of somatosensory evoked potential monitoring in evaluating neurological complications during endovascular aneurysm treatment","volume":"14","author":"Ares","year":"2018","journal-title":"Oper Neurosurg"},{"key":"2024111104061190000_13.4.378.6","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1016\/j.clinph.2010.09.001","article-title":"The use of motor evoked potential monitoring during cerebral aneurysm surgery to predict pure motor deficits due to subcortical ischemia","volume":"122","author":"Guo","year":"2011","journal-title":"Clin Neurophysiol"},{"key":"2024111104061190000_13.4.378.7","doi-asserted-by":"crossref","first-page":"275","DOI":"10.3171\/jns.2005.103.2.0275","article-title":"Intraoperative monitoring of blood flow insufficiency during surgery of middle cerebral artery aneurysms","volume":"103","author":"Horiuchi","year":"2005","journal-title":"J Neurosurg"},{"key":"2024111104061190000_13.4.378.8","doi-asserted-by":"crossref","first-page":"507","DOI":"10.3171\/jns.2003.98.3.0507","article-title":"Intraoperative monitoring of blood flow insufficiency in the anterior choroidal artery during aneurysm surgery","volume":"98","author":"Suzuki","year":"2003","journal-title":"J Neurosurg"},{"key":"2024111104061190000_13.4.378.9","doi-asserted-by":"crossref","first-page":"785","DOI":"10.3171\/jns.1996.84.5.0785","article-title":"Temporary vessel occlusion for aneurysm surgery: risk factors for stroke in patients protected by induced hypothermia and hypertension and intravenous mannitol administration","volume":"84","author":"Ogilvy","year":"1996","journal-title":"J Neurosurg"},{"key":"2024111104061190000_13.4.378.10","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011459"},{"key":"2024111104061190000_13.4.378.11","doi-asserted-by":"publisher","DOI":"10.1159\/000354982"},{"key":"2024111104061190000_13.4.378.12","first-page":"1498","article-title":"Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients","volume":"27","author":"van Rooij","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"2024111104061190000_13.4.378.13","doi-asserted-by":"crossref","unstructured":"Gonzalez LF , Albuquerque F , McDougall C . Neurointerventionl techniques: tricks of the trade. In: Neurointerventionl techniques: tricks of the trade. 1st ed, 2014.","DOI":"10.1055\/b-0034-102504"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2020-016604","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T12:08:01Z","timestamp":1731326881000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2020-016604"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,22]]},"references-count":13,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,3,15]]},"published-print":{"date-parts":[[2021,4]]}},"alternative-id":["10.1136\/neurintsurg-2020-016604"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2020-016604","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,22]]}}}