{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T16:32:47Z","timestamp":1788453167393,"version":"build-2803163510"},"reference-count":28,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2021,3,15]],"date-time":"2021-03-15T00:00:00Z","timestamp":1615766400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2021,2,26]]},"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Self-expanding stents are increasingly being deployed for stent-assisted coiling or flow diversion of intracranial aneurysms. Complications related to stent misbehavior may arise, however, including lack of expansion, device displacement, or parent vessel thrombosis. We present our experience of various stent removal techniques (stentectomy) with a focus on technical and clinical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Stentectomy was attempted either with a single device, including the Alligator, Microsnare, or Solitaire, or by combining a Microsnare with a second device. Dual techniques included in this report are the Snare-over-Stentretriever technique we developed using a Microsnare and a Solitaire, and the previously described Loop-and-Snare technique using a Microsnare and a microwire. The technical success and complication rate, as well as the clinical outcome using the mRS were analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Forty-seven stentectomies were attempted in 36 patients treated for 37 aneurysms. Forty-two devices (89.3%) were successfully retrieved. Single-device stentectomy was successful in 34% of cases, compared with 74% with dual-device techniques. Of the 20 patients with a thrombosed parent or efferent vessel, 17 were successfully recanalized using stentectomy. All successful stentectomy patients made a clinically uneventful recovery, except one with a minor postoperative stroke (mRS 1 at discharge). Failed stentectomy was associated with major ischemic stroke in two patients and death in one patient. There were no stentectomy-related vessel perforations or dissections.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>While various single devices can be used to safely retrieve dysfunctional intracranial self-expandable stents, dual-device techniques are more than twice as effective, according to our experience.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/neurintsurg-2021-017279","type":"journal-article","created":{"date-parts":[[2021,3,15]],"date-time":"2021-03-15T13:21:56Z","timestamp":1615814516000},"page":"160-163","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":13,"title":["Bailout stentectomy of 47 self-expandable intracranial stents"],"prefix":"10.1136","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2584-8361","authenticated-orcid":false,"given":"Ren\u00e9","family":"Chapot","sequence":"first","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian Paul","family":"Stracke","sequence":"additional","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Wallocha","sequence":"additional","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5446-8587","authenticated-orcid":false,"given":"Reza","family":"Rikhtegar","sequence":"additional","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elif","family":"Yamac","sequence":"additional","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5111-1972","authenticated-orcid":false,"given":"Pascal John","family":"Mosimann","sequence":"additional","affiliation":[{"name":"Department of Intracranial Endovascular Therapy, Alfried Krupp Krankenhaus Essen, Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2021,3,15]]},"reference":[{"key":"2025092911594128000_14.2.160.1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4066"},{"key":"2025092911594128000_14.2.160.2","doi-asserted-by":"crossref","first-page":"435","DOI":"10.2176\/nmc.oa.2018-0131","article-title":"Evaluation of acute in-stent thrombosis during stent-assisted coil embolization of unruptured intracranial aneurysms","volume":"58","author":"Nii","year":"2018","journal-title":"Neurol Med Chir"},{"key":"2025092911594128000_14.2.160.3","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1159\/000489016","article-title":"Bailout strategies and complications associated with the use of flow-diverting stents for treating intracranial aneurysms","volume":"8","author":"Al-Mufti","year":"2020","journal-title":"Interv Neurol"},{"key":"2025092911594128000_14.2.160.4","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012263.rep"},{"key":"2025092911594128000_14.2.160.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2015.05.013"},{"key":"2025092911594128000_14.2.160.6","first-page":"160","article-title":"Stentectomy: retrieval of stents after stent assisted coiling","volume":"21","author":"Chapot","year":"2015","journal-title":"Intervent Neuroradiol"},{"key":"2025092911594128000_14.2.160.7","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.wneu.2015.08.066","article-title":"Rescue retrieval of a fully deployed low-profile intracranial stent after acute occlusion","volume":"85","author":"Barburoglu","year":"2016","journal-title":"World Neurosurg"},{"key":"2025092911594128000_14.2.160.8","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2016-012547.rep"},{"key":"2025092911594128000_14.2.160.9","first-page":"804","article-title":"An endovascular retrieving device for use in small vessels","volume":"14","author":"Graves","year":"1993","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025092911594128000_14.2.160.10","doi-asserted-by":"crossref","first-page":"247","DOI":"10.2176\/nmc.35.247","article-title":"Retrieval of a migrated detachable coil--case report","volume":"35","author":"Watanabe","year":"1995","journal-title":"Neurol Med Chir"},{"key":"2025092911594128000_14.2.160.11","doi-asserted-by":"publisher","DOI":"10.1016\/S0720-048X(03)00078-0"},{"key":"2025092911594128000_14.2.160.12","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000163685.23846.DD"},{"key":"2025092911594128000_14.2.160.13","doi-asserted-by":"crossref","first-page":"50","DOI":"10.5469\/neuroint.2012.7.1.50","article-title":"Foreign body removal by SNARE loop: during intracranial stent procedure","volume":"7","author":"Oh","year":"2012","journal-title":"Neurointervention"},{"key":"2025092911594128000_14.2.160.14","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-006-0062-7"},{"key":"2025092911594128000_14.2.160.15","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.001232"},{"key":"2025092911594128000_14.2.160.16","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-010-0020-y"},{"key":"2025092911594128000_14.2.160.17","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3552"},{"key":"2025092911594128000_14.2.160.18","first-page":"327","article-title":"A new device for endovascular coil retrieval from intracranial vessels: alligator retrieval device","volume":"27","author":"Henkes","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025092911594128000_14.2.160.19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2012\/242101","article-title":"Treatment of endovascular coil and stent migration using the merci retriever: report of three cases","volume":"2012","author":"Kung","year":"2012","journal-title":"Case Rep Med"},{"key":"2025092911594128000_14.2.160.20","doi-asserted-by":"publisher","DOI":"10.1111\/j.1552-6569.2007.00165.x"},{"key":"2025092911594128000_14.2.160.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2013.10.012"},{"key":"2025092911594128000_14.2.160.22","doi-asserted-by":"crossref","first-page":"139","DOI":"10.4329\/wjr.v7.i6.139","article-title":"Endovascular retrieval of a prematurely deployed covered stent","volume":"7","author":"Miley","year":"2015","journal-title":"World J Radiol"},{"key":"2025092911594128000_14.2.160.23","first-page":"1819","article-title":"Management of neuroform stent dislodgement and misplacement","volume":"24","author":"Broadbent","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025092911594128000_14.2.160.24","doi-asserted-by":"crossref","first-page":"841","DOI":"10.3171\/2015.1.JNS132788","article-title":"Early surgical removal of migrated coil\/stent after failed embolization of intracranial aneurysm","volume":"123","author":"Turek","year":"2015","journal-title":"J Neurosurg"},{"key":"2025092911594128000_14.2.160.25","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0178197","article-title":"Endovascular stentectomy using the SNARE over stent-retriever (SOS) technique: an experimental feasibility study","volume":"12","author":"Meyer","year":"2017","journal-title":"PLoS One"},{"key":"2025092911594128000_14.2.160.26","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011466"},{"key":"2025092911594128000_14.2.160.27","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1007\/s00234-018-2088-z","article-title":"Low rates of recanalization for wide-necked aneurysms treated with stenting after balloon-assisted coiling: combination of techniques delivers stable and improved results during follow-up","volume":"60","author":"Velasco Gonz\u00e1lez","year":"2018","journal-title":"Neuroradiology"},{"key":"2025092911594128000_14.2.160.28","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-010-9338-1"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2021-017279","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T18:59:48Z","timestamp":1759172388000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2021-017279"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,15]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,1,18]]},"published-print":{"date-parts":[[2022,2]]}},"alternative-id":["10.1136\/neurintsurg-2021-017279"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2021-017279","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,15]]}}}