{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T22:32:01Z","timestamp":1765233121562,"version":"3.37.3"},"reference-count":10,"publisher":"BMJ","issue":"3","license":[{"start":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T00:00:00Z","timestamp":1623888000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2021,5,11]]},"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:p>Numerous devices and sophisticated strategies have been developed to further increase the number of aneurysms amenable to endovascular treatment.1\u20134 Despite the superfluity of available neurovascular armamentarium, wide-necked bifurcation aneurysms can still pose a significant technical challenge to the treating clinician.5\u20137 Neck bridging is a conceptually new approach, which provides increased occlusion rates with lower recurrence and complications rates.8\u201310 The Nautilus (EndoStream Medical) is an intrasaccular bridging device intended to assist in coil embolization of wide-necked cerebral aneurysms. This CE-marked device, available in various sizes, consists of flexible-layers, and is a nitinol-based, detachable implant. The device is delivered through a standard microcatheter with a minimal 0.0165\" inner diameter and is fully radiopaque and completely resheathable.<\/jats:p><jats:p>Owing to its unique \u2018tornado\u2019 like shape the device entirely reconstructs the aneurysmal neck, which facilitates the following coil embolization. In this video 1, we demonstrate the use of Nautilus - assisted coil embolization for a complex anterior communicating artery (AcomA) wide-necked aneurysm in the setting of acute subarachnoid hemorrhage.<\/jats:p><jats:p><jats:fig position=\"float\" id=\"V1\" orientation=\"portrait\"><jats:label>Video 1<\/jats:label><jats:media xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:role=\"media-player-id\" xlink:href=\"BMJ Journals Video Player\" id=\"media1\" mimetype=\"application\" mime-subtype=\"mp4\" content-type=\"play-in-place height-270 width-480\" position=\"float\" orientation=\"portrait\"\/><\/jats:fig><\/jats:p>","DOI":"10.1136\/neurintsurg-2021-017670","type":"journal-article","created":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T17:35:58Z","timestamp":1623951358000},"page":"310-310","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":5,"title":["Nautilus-assisted coil embolization for a complex AcomA wide-necked aneurysm in the setting of acute subarachnoid hemorrhage"],"prefix":"10.1136","volume":"14","author":[{"given":"Alexander","family":"Sirakov","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Svetozar","family":"Matanov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pervinder","family":"Bhogal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6034-5340","authenticated-orcid":false,"given":"Stanimir","family":"Sirakov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2021,6,17]]},"reference":[{"key":"2024052306473269000_14.3.310.1","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1093\/neuros\/nyaa590","article-title":"Safety, efficacy, and durability of stent plus balloon-assisted coiling for the treatment of wide-necked intracranial bifurcation aneurysms","volume":"88","author":"Aydin","year":"2021","journal-title":"Neurosurgery"},{"key":"2024052306473269000_14.3.310.2","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015628"},{"key":"2024052306473269000_14.3.310.3","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015746"},{"key":"2024052306473269000_14.3.310.4","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.119.028418"},{"key":"2024052306473269000_14.3.310.5","unstructured":"Aguilar P\u00e9rez M , Hellstern V , AlMatter M . The Medina embolic device \u2013 clinical experience in 34 aneurysms from a single center. 14th Congress of The World Federation of Interventional and Therapeutic Neuroradiology, 2017."},{"key":"2024052306473269000_14.3.310.6","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014623"},{"key":"2024052306473269000_14.3.310.7","doi-asserted-by":"crossref","first-page":"159","DOI":"10.3171\/2019.3.JNS183160","article-title":"Wide-neck aneurysms: systematic review of the neurosurgical literature with a focus on definition and clinical implications","volume":"133","author":"Hendricks","year":"2020","journal-title":"J Neurosurg"},{"key":"2024052306473269000_14.3.310.8","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1093\/neuros\/nyaa200","article-title":"Comaneci-assisted coiling as a treatment option for acutely ruptured wide neck cerebral aneurysm: case series of 118 patients","volume":"87","author":"Sirakov","year":"2020","journal-title":"Neurosurgery"},{"key":"2024052306473269000_14.3.310.9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015338"},{"key":"2024052306473269000_14.3.310.10","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1177\/1591019920925708","article-title":"The Cascade device \u2013 in vitro tests to assess coil protrusion into the parent vessel","volume":"26","author":"Bhogal","year":"2020","journal-title":"Interv Neuroradiol"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2021-017670","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T13:47:41Z","timestamp":1716472061000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2021-017670"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,17]]},"references-count":10,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,2,16]]},"published-print":{"date-parts":[[2022,3]]}},"alternative-id":["10.1136\/neurintsurg-2021-017670"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2021-017670","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"type":"print","value":"1759-8478"},{"type":"electronic","value":"1759-8486"}],"subject":[],"published":{"date-parts":[[2021,6,17]]}}}