{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:21:32Z","timestamp":1787170892711,"version":"build-2736575974"},"reference-count":23,"publisher":"BMJ","issue":"11","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2022,1,27]]},"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Surface-modified flow diverters (FDs) designed to reduce thrombogenicity represent the next frontier for intracranial aneurysm treatment. The Derivo Embolization Device (DED) is a novel FD with titanium oxide and titanium oxynitride finishing of the struts. We performed a systematic review of pertinent literature, aiming to evaluate the device\u2019s effectiveness and safety.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A literature search of PubMed, Embase, and MEDLINE was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Five studies comprising 481 aneurysms were included. These studies were conducted in Turkey, Brazil, Germany, Poland, and Italy; two were prospective and three were retrospective. Twenty-six aneurysms (5.4%) were ruptured. The antiplatelet regimens were heterogeneous, but dual antiplatelet therapy was administered preprocedurally in all studies and maintained for 3\u201312 months before a switch to single antiplatelet therapy. The rate of periprocedural ischemic and hemorrhagic complications was 4.9% (95% CI 2.9% to 7%). Adjunctive coiling was used in 25.6% (95% CI 11.4% to 39.8%) of aneurysms. The complete angiographic occlusion rate was 81.4% (95% CI 71.3% to 91.5%), mortality rate was 2.1% (95% CI 0.4% to 3.9%), with follow-up ranging from 9 to 18 months. Delayed aneurysm rupture was reported in one patient.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The DED has been increasingly used in other countries. We identified low rates of periprocedural complications and mortality and a high rate of complete occlusion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/neurintsurg-2021-018390","type":"journal-article","created":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T13:25:40Z","timestamp":1646141140000},"page":"1125-1129","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":34,"title":["A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment"],"prefix":"10.1136","volume":"14","author":[{"given":"Andre","family":"Monteiro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha M","family":"Burke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammad A","family":"Baig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Slah","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin M","family":"Cappuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4500-7954","authenticated-orcid":false,"given":"Muhammad","family":"Waqas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph E","family":"Dietrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6208-3724","authenticated-orcid":false,"given":"Elad I","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9519-0059","authenticated-orcid":false,"given":"Adnan H","family":"Siddiqui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2022,3,1]]},"reference":[{"key":"2024052307014314000_14.11.1125.1","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015091"},{"key":"2024052307014314000_14.11.1125.2","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.112.678151"},{"key":"2024052307014314000_14.11.1125.3","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016245"},{"key":"2024052307014314000_14.11.1125.4","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.07.101"},{"key":"2024052307014314000_14.11.1125.5","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016303"},{"key":"2024052307014314000_14.11.1125.6","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.119.025407"},{"key":"2024052307014314000_14.11.1125.7","doi-asserted-by":"publisher","DOI":"10.1186\/s13643-016-0384-4"},{"key":"2024052307014314000_14.11.1125.8","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-010-0767-5"},{"key":"2024052307014314000_14.11.1125.9","doi-asserted-by":"publisher","DOI":"10.1177\/159101991001600204"},{"key":"2024052307014314000_14.11.1125.10","doi-asserted-by":"publisher","DOI":"10.1161\/hs0901.095600"},{"key":"2024052307014314000_14.11.1125.11","doi-asserted-by":"crossref","first-page":"361","DOI":"10.23736\/S0390-5616.21.05300-5","article-title":"Long-term follow-up of the Derivo\u00ae embolization device (DED\u00ae) for intracranial aneurysms: the Italian multicentric registry","volume":"65","author":"Piano","year":"2021","journal-title":"J Neurosurg Sci"},{"key":"2024052307014314000_14.11.1125.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2019.03.137"},{"key":"2024052307014314000_14.11.1125.13","doi-asserted-by":"crossref","first-page":"361","DOI":"10.23736\/S0390-5616.21.05300-5","article-title":"Long-term follow-up of the Derivo\u00ae embolization device (DED\u00ae) for intracranial aneurysms: the Italian multicentric registry","volume":"65","author":"Piano","year":"2021","journal-title":"J Neurosurg Sci"},{"key":"2024052307014314000_14.11.1125.14","doi-asserted-by":"crossref","first-page":"222","DOI":"10.5469\/neuroint.2021.00234","article-title":"Silk\u00ae flow diverter device for intracranial aneurysm treatment: a systematic review and meta-analysis","volume":"16","author":"Florez","year":"2021","journal-title":"Neurointervention"},{"key":"2024052307014314000_14.11.1125.15","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4078"},{"key":"2024052307014314000_14.11.1125.16","first-page":"159101992110279","article-title":"Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review","author":"Waqas","year":"2021","journal-title":"Interv Neuroradiol"},{"key":"2024052307014314000_14.11.1125.17","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2017.08.003"},{"key":"2024052307014314000_14.11.1125.18","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-014937"},{"key":"2024052307014314000_14.11.1125.19","doi-asserted-by":"crossref","unstructured":"Cappuzzo JM , Monteiro A , Taylor MN , et al . First U.S. experience using the Pipeline Flex embolization device with Shield Technology for treatment of intracranial aneurysms. World Neurosurg 2021;80.doi:10.1016\/j.wneu.2021.12.031","DOI":"10.1016\/j.wneu.2021.12.031"},{"key":"2024052307014314000_14.11.1125.20","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1177\/1971400920966749","article-title":"Pipeline flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes","volume":"33","author":"Yeomans","year":"2020","journal-title":"Neuroradiol J"},{"key":"2024052307014314000_14.11.1125.21","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014166"},{"key":"2024052307014314000_14.11.1125.22","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2018-014363"},{"key":"2024052307014314000_14.11.1125.23","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5730"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2021-018390","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T10:02:06Z","timestamp":1716458526000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2021-018390"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,1]]},"references-count":23,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,10,14]]},"published-print":{"date-parts":[[2022,11]]}},"alternative-id":["10.1136\/neurintsurg-2021-018390"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2021-018390","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,1]]}}}