{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T01:26:35Z","timestamp":1769045195574,"version":"3.49.0"},"reference-count":6,"publisher":"BMJ","issue":"10","license":[{"start":{"date-parts":[[2022,2,8]],"date-time":"2022-02-08T00:00:00Z","timestamp":1644278400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["J NeuroIntervent Surg"],"accepted":{"date-parts":[[2022,1,20]]},"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:p>Smart angiography suites (SAS) refer to the incorporation of audio-video technology and internet connectivity into the angiography suite to enable bidirectional communication for teleproctoring. Remote streaming support (RESS) is intended to increase patient safety by supporting interventionalists with limited experience or who are practicing in geographically remote areas. The aim of this review is to describe real-life experience of the Tegus system and to share practical tips concerning its use and setup. We describe the platform itself, settings and integration in our angiography suite. We provide technical tips intended to help new and potential users to achieve an optimal experience for both neurointerventionalists and proctors. We describe both elective cases that we have performed with teleproctoring and emergencies. Lastly, we describe a different room setup and software solutions used in live workshops. Use of teleproctoring enabled involvement of proctors in cases where an already experienced interventionalist needed support in the decision-making process concerning the sizing and deployment of devices with which he was familiar only on a basic level. Excellent video feed quality and instant communication enabled optimal preparation and in vivo implantation of those devices without the need for physical proctors\u2019 presence. In emergency cases the system allowed a senior physician to offer support during cases where optimal device sizing is critical. Our usage concept of the rig permitted monitoring of thrombectomy cases by junior physicians. During webinars a remote streaming platform enabled us to conduct workshops that simulated an \u201con-site\u201d experience as closely as possible during the COVID-19 pandemic.<\/jats:p>","DOI":"10.1136\/neurintsurg-2021-018401","type":"journal-article","created":{"date-parts":[[2022,2,8]],"date-time":"2022-02-08T18:20:26Z","timestamp":1644344426000},"page":"976-978","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":6,"title":["Technical considerations and tips for using the Tegus remote proctoring system in elective and emergency cases and in webinars"],"prefix":"10.1136","volume":"14","author":[{"given":"Alexander","family":"von Hessling","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3080-1568","authenticated-orcid":false,"given":"Tom\u00e1s","family":"Reyes del Castillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justus Erasmus","family":"Roos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Grzegorz Marek","family":"Karwacki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2022,2,8]]},"reference":[{"key":"2024052307015827000_14.10.976.1","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2021-017383","article-title":"The smart angiography suite","volume":"14","author":"Lim","year":"2022","journal-title":"J Neurointerv Surg"},{"key":"2024052307015827000_14.10.976.2","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s00062-019-00870-5","article-title":"Training and supervision of thrombectomy by remote live streaming support (RESS) : randomized comparison using simulated stroke interventions","volume":"31","author":"Bechstein","year":"2021","journal-title":"Clin Neuroradiol"},{"key":"2024052307015827000_14.10.976.3","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.amjsurg.2019.07.018","article-title":"Telemedicine and telementoring in the surgical specialties: a narrative review","volume":"218","author":"Huang","year":"2019","journal-title":"Am J Surg"},{"key":"2024052307015827000_14.10.976.4","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2020-016722"},{"key":"2024052307015827000_14.10.976.5","doi-asserted-by":"crossref","first-page":"70","DOI":"10.9743\/JIR.2019.8.2.7","article-title":"Using OBS to create video lectures for online counseling students","volume":"8","author":"Kaufmann","year":"2019","journal-title":"J Instruction Res"},{"key":"2024052307015827000_14.10.976.6","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.apergo.2018.02.015","article-title":"Are gestures worth a thousand words? Verbal and nonverbal communication during robot-assisted surgery","volume":"78","author":"Tiferes","year":"2019","journal-title":"Appl Ergon"}],"container-title":["Journal of NeuroInterventional Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/neurintsurg-2021-018401","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T03:23:06Z","timestamp":1726629786000},"score":1,"resource":{"primary":{"URL":"https:\/\/jnis.bmj.com\/lookup\/doi\/10.1136\/neurintsurg-2021-018401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,8]]},"references-count":6,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2022,9,14]]},"published-print":{"date-parts":[[2022,10]]}},"alternative-id":["10.1136\/neurintsurg-2021-018401"],"URL":"https:\/\/doi.org\/10.1136\/neurintsurg-2021-018401","relation":{},"ISSN":["1759-8478","1759-8486"],"issn-type":[{"value":"1759-8478","type":"print"},{"value":"1759-8486","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,8]]}}}