{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T15:17:58Z","timestamp":1791299878160,"version":"4.1.0"},"reference-count":35,"publisher":"BMJ","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Occup Environ Med"],"published-print":{"date-parts":[[2002,11]]},"abstract":"<jats:p><jats:bold>Aims:<\/jats:bold>To evaluate possible differences between men and women in acute health effects after controlled short term chamber exposure to vapours of two common organic solvents.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold>Fifty six healthy volunteers (28 per sex) were exposed to 150 ppm 2-propanol, 50 ppm<jats:italic>m<\/jats:italic>-xylene, and clean air for two hours at rest. The subjects rated symptoms on a visual analogue scale before, during, and after the exposure. Blinking frequency was measured continuously during exposure. Pulmonary function, nasal swelling, inflammatory markers (lysozyme, eosinophilic cationic potein, myeloperoxidase, albumin) in nasal lavage and colour vision (Lanthony D-15 desaturated panel) were measured before and at 0 and 3 hours after the exposure.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold>There were no significant sex differences in response to solvent exposure with respect to blinking frequency, lung diffusing capacity, nasal area and volume, inflammatory markers in nasal lavage, and colour vision. Increased symptoms were rated by both sexes for nearly all 10 questions during exposure to 2-propanol or<jats:italic>m<\/jats:italic>-xylene, most increases being significant at one time point at least. The rating of \u201cdiscomfort in the throat or airways\u201d increased more in women during exposure to 2-propanol or<jats:italic>m<\/jats:italic>-xylene. During exposure to 2-propanol the rating of \u201cfatigue\u201d was more increased in men after one hour, but more increased in women after two hours of exposure. With regard to pulmonary function, women had small but significant decreases in FVC, FEV<jats:sub>1<\/jats:sub>\/FVC, and FEF<jats:sub>75<\/jats:sub>three hours after exposure to<jats:italic>m<\/jats:italic>-xylene, but only the decrease in FVC was significantly different from that in men.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold>Our results suggest that women are slightly more sensitive than men to the acute irritative effects of 2-propanol and<jats:italic>m<\/jats:italic>-xylene vapours.<\/jats:p>","DOI":"10.1136\/oem.59.11.759","type":"journal-article","created":{"date-parts":[[2002,10,30]],"date-time":"2002-10-30T19:22:23Z","timestamp":1036005743000},"page":"759-767","source":"Crossref","is-referenced-by-count":52,"title":["Are women more sensitive than men to 2-propanol and<i>m<\/i>-xylene vapours?"],"prefix":"10.1136","volume":"59","author":[{"given":"L","family":"Ernstg\u00e5rd","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E","family":"Gullstrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"L\u00f6f","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Johanson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2002,11,1]]},"reference":[{"key":"2024052311002892000_59.11.759.1","unstructured":"Statistics. Statistical yearbook of Sweden 99, Vol 85. \u00d6rebro, Sweden: Statistics, 1999."},{"key":"2024052311002892000_59.11.759.2","first-page":"3773","volume":"90","year":"1993","journal-title":"L\u00e4kartidningen"},{"key":"2024052311002892000_59.11.759.3","unstructured":"Isopropanol. In: Harbison RD, ed. Hamilton & Hardy\u2019s industrial toxicology, 5th edn. St Louis: Laura De Young, 1998."},{"key":"2024052311002892000_59.11.759.4","unstructured":"NIOSH. Occupational exposure to isopropyl alcohol. HEW publication no. (NIOSH). 1976:76\u2013142."},{"key":"2024052311002892000_59.11.759.5","unstructured":"SWEA. Provisions and general recommendations. Ordinance AFS 2000:3. Swedish Work Environment Authority, 2000."},{"key":"2024052311002892000_59.11.759.6","unstructured":"ACGIH. Documentation of the threshold limit values and biological exposure indices. American Coference of Governmental Industrial Hygienists, 2000."},{"key":"2024052311002892000_59.11.759.7","unstructured":"IPCS. Xylenes. Environmental Health Criteria 190. IPCS, 1997."},{"key":"2024052311002892000_59.11.759.8","doi-asserted-by":"publisher","DOI":"10.1006\/rtph.1996.0081"},{"key":"2024052311002892000_59.11.759.9","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1111\/j.1600-0668.1993.t01-1-00002.x","volume":"3","year":"1993","journal-title":"Indoor Air"},{"key":"2024052311002892000_59.11.759.10","doi-asserted-by":"publisher","DOI":"10.1097\/00043764-199107000-00006"},{"key":"2024052311002892000_59.11.759.11","doi-asserted-by":"publisher","DOI":"10.1007\/s004200050270"},{"key":"2024052311002892000_59.11.759.12","doi-asserted-by":"crossref","first-page":"271","DOI":"10.5271\/sjweh.2221","volume":"11","year":"1985","journal-title":"Scand J Work Environ Health"},{"key":"2024052311002892000_59.11.759.13","doi-asserted-by":"publisher","DOI":"10.1007\/BF00914095"},{"key":"2024052311002892000_59.11.759.14","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1172\/JCI114329","volume":"84","year":"1989","journal-title":"J Clin Invest"},{"key":"2024052311002892000_59.11.759.15","doi-asserted-by":"publisher","DOI":"10.1006\/taap.1996.0223"},{"key":"2024052311002892000_59.11.759.16","doi-asserted-by":"publisher","DOI":"10.1016\/S0041-008X(05)80002-X"},{"key":"2024052311002892000_59.11.759.17","doi-asserted-by":"publisher","DOI":"10.1006\/enrs.1993.1132"},{"key":"2024052311002892000_59.11.759.18","doi-asserted-by":"publisher","DOI":"10.1136\/oem.54.7.457"},{"key":"2024052311002892000_59.11.759.19","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1172\/JCI102987","volume":"33","year":"1954","journal-title":"J Clin Invest"},{"key":"2024052311002892000_59.11.759.20","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1152\/jappl.1989.66.1.295","volume":"66","year":"1989","journal-title":"J Appl Physiol"},{"key":"2024052311002892000_59.11.759.21","doi-asserted-by":"publisher","DOI":"10.1093\/toxsci\/46.1.143"},{"key":"2024052311002892000_59.11.759.22","unstructured":"Gullstrand E, Sk\u00f6ldstr\u00f6m B, Johanson M, et al. Recording of blink frequency by computerised EMG analysis. Singapore: ICOH, 2000."},{"key":"2024052311002892000_59.11.759.23","first-page":"185","volume":"46","year":"1978","journal-title":"Doc Ophthalmol"},{"key":"2024052311002892000_59.11.759.24","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1080\/00039890009604037","volume":"55","year":"2000","journal-title":"Arch Environ Health"},{"key":"2024052311002892000_59.11.759.25","doi-asserted-by":"crossref","first-page":"9","DOI":"10.3109\/02813439008994923","volume":"8","year":"1990","journal-title":"Scand J Prim Health Care"},{"key":"2024052311002892000_59.11.759.26","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1177\/074823379401000519","volume":"10","year":"1994","journal-title":"Toxicol Ind Health"},{"key":"2024052311002892000_59.11.759.27","doi-asserted-by":"publisher","DOI":"10.1097\/00043764-199803000-00013"},{"key":"2024052311002892000_59.11.759.28","doi-asserted-by":"crossref","first-page":"271","DOI":"10.5271\/sjweh.2221","volume":"11","year":"1985","journal-title":"Scand J Work Environ Health"},{"key":"2024052311002892000_59.11.759.29","doi-asserted-by":"publisher","DOI":"10.1093\/toxsci\/48.2.189"},{"key":"2024052311002892000_59.11.759.30","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1164\/ajrccm.159.4.9703106","volume":"159","year":"1999","journal-title":"Am J Respir Crit Care Med"},{"key":"2024052311002892000_59.11.759.31","first-page":"209","volume":"34","year":"1990","journal-title":"Indian J Physiol Pharmacol"},{"key":"2024052311002892000_59.11.759.32","first-page":"112","volume":"24","year":"1980","journal-title":"Indian J Physiol Pharmacol"},{"key":"2024052311002892000_59.11.759.33","first-page":"L110","volume":"270","year":"1996","journal-title":"Am J Physiol"},{"key":"2024052311002892000_59.11.759.34","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1164\/ajrccm\/143.5_Pt_1.978","volume":"143","year":"1991","journal-title":"Am Rev Respir Dis"},{"key":"2024052311002892000_59.11.759.35","doi-asserted-by":"crossref","first-page":"341","DOI":"10.2500\/105065898780182462","volume":"12","year":"1998","journal-title":"Am J Rhinol"}],"container-title":["Occupational and Environmental Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/oem.59.11.759","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T19:00:17Z","timestamp":1716490817000},"score":1,"resource":{"primary":{"URL":"https:\/\/oem.bmj.com\/lookup\/doi\/10.1136\/oem.59.11.759"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,11]]},"references-count":35,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2002,11,1]]},"published-print":{"date-parts":[[2002,11]]}},"alternative-id":["10.1136\/oem.59.11.759"],"URL":"https:\/\/doi.org\/10.1136\/oem.59.11.759","relation":{},"ISSN":["1351-0711","1470-7926"],"issn-type":[{"value":"1351-0711","type":"print"},{"value":"1470-7926","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,11]]}}}