{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T05:14:26Z","timestamp":1769836466348,"version":"3.49.0"},"reference-count":23,"publisher":"BMJ","issue":"3","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Occup Environ Med"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1136\/oemed-2015-103019","type":"journal-article","created":{"date-parts":[[2015,11,12]],"date-time":"2015-11-12T02:38:54Z","timestamp":1447295934000},"page":"161-166","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":40,"title":["Exposure to MRI-related magnetic fields and vertigo in MRI workers"],"prefix":"10.1136","volume":"73","author":[{"given":"Kristel","family":"Schaap","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00fctzen","family":"Portengen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans","family":"Kromhout","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2015,11,11]]},"reference":[{"key":"key-10.1136\/oemed-2015-103019-1","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1097\/01.HP.0000343164.27920.4a","article-title":"Guidelines on limits of exposure to static magnetic fields","volume":"96","author":"International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2009","journal-title":"Health Phys"},{"key":"key-10.1136\/oemed-2015-103019-2","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1097\/HP.0b013e31829e5580","article-title":"Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1\u2005Hz","volume":"106","author":"International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2014","journal-title":"Health Phys"},{"key":"key-10.1136\/oemed-2015-103019-3","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1136\/oemed-2013-101890","article-title":"Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5\u20137 Tesla MRI scanners is associated with reporting of transient symptoms","volume":"71","author":"Schaap","year":"2014","journal-title":"Occup Environ Med"},{"key":"key-10.1136\/oemed-2015-103019-4","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1002\/jmri.20485","article-title":"Exposure, health complaints and cognitive performance among employees of an MRI scanners manufacturing department","volume":"23","author":"de Vocht","year":"2006","journal-title":"J Magn Reson Imaging"},{"key":"key-10.1136\/oemed-2015-103019-5","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1016\/j.ejrad.2010.09.021","article-title":"Health complaints among nurses working near MRI scanners\u2014a descriptive pilot study","volume":"80","author":"Wil\u00e9n","year":"2011","journal-title":"Eur J Radiol"},{"key":"key-10.1136\/oemed-2015-103019-6","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1002\/bem.20316","article-title":"Magnetic-field-induced vertigo: a theoretical and experimental investigation","volume":"28","author":"Glover","year":"2007","journal-title":"Bioelectromagnetics"},{"key":"key-10.1136\/oemed-2015-103019-7","doi-asserted-by":"crossref","first-page":"e78748","DOI":"10.1371\/journal.pone.0078748","article-title":"On the vertigo due to static magnetic fields","volume":"8","author":"Mian","year":"2013","journal-title":"PLoS ONE"},{"key":"key-10.1136\/oemed-2015-103019-8","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1016\/j.cub.2011.08.029","article-title":"MRI magnetic field stimulates rotational sensors of the brain","volume":"21","author":"Roberts","year":"2011","journal-title":"Curr Biol"},{"key":"key-10.1136\/oemed-2015-103019-9","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1002\/bem.20680","article-title":"A large-scale study on subjective perception of discomfort during 7 and 1.5\u2005T MRI examinations","volume":"32","author":"Heilmaier","year":"2011","journal-title":"Bioelectromagnetics"},{"key":"key-10.1136\/oemed-2015-103019-10","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s10334-007-0095-x","article-title":"Subjective acceptance of 7 Tesla MRI for human imaging","volume":"21","author":"Theysohn","year":"2008","journal-title":"MAGMA"},{"key":"key-10.1136\/oemed-2015-103019-11","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/RLI.0000000000000035","article-title":"Multicenter study of subjective acceptance during magnetic resonance imaging at 7 and 9.4\u2005T","volume":"49","author":"Rauschenberg","year":"2014","journal-title":"Invest Radiol"},{"key":"key-10.1136\/oemed-2015-103019-12","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1002\/jmri.22221","article-title":"Vital signs and cognitive function are not affected by 23-sodium and 17-oxygen magnetic resonance imaging of the human brain at 9.4\u2005T","volume":"32","author":"Atkinson","year":"2010","journal-title":"J Magn Reson Imaging"},{"key":"key-10.1136\/oemed-2015-103019-13","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1002\/jmri.23904","article-title":"Subject tolerance of 7\u2005T MRI examinations","volume":"38","author":"Versluis","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"key-10.1136\/oemed-2015-103019-14","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1093\/annhyg\/meu057","article-title":"Exposure to static and time-varying magnetic fields from working in the static magnetic stray fields of MRI scanners: a comprehensive survey in the Netherlands","volume":"58","author":"Schaap","year":"2014","journal-title":"Ann Occup Hyg"},{"key":"key-10.1136\/oemed-2015-103019-15","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1109\/TBME.2007.913410","article-title":"Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments","volume":"55","author":"Fuentes","year":"2008","journal-title":"IEEE Trans Biomed Eng"},{"key":"key-10.1136\/oemed-2015-103019-16","doi-asserted-by":"crossref","first-page":"5247","DOI":"10.1016\/j.csda.2006.08.014","article-title":"Fitting finite mixtures of generalized linear regressions in R","volume":"51","author":"Gr\u00fcn","year":"2007","journal-title":"Comput Stat Data Anal"},{"key":"key-10.1136\/oemed-2015-103019-17","first-page":"1","article-title":"FlexMix Version 2: finite mixtures with concomitant variables and varying and constant parameters","volume":"28","author":"Gruen","year":"2008","journal-title":"J Stat Softw"},{"key":"key-10.1136\/oemed-2015-103019-18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v011.i08","article-title":"FlexMix: a general framework for finite mixture models and latent class regression in R","volume":"11","author":"Leisch","year":"2004","journal-title":"J Stat Softw"},{"key":"key-10.1136\/oemed-2015-103019-19","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1109\/TAC.1974.1100705","article-title":"A new look at the statistical model identification","volume":"19","author":"Akaike","year":"1974","journal-title":"IEEE Trans Automat Contr"},{"key":"key-10.1136\/oemed-2015-103019-20","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2307\/271063","article-title":"Bayesian model selection in social research","volume":"25","author":"Raftery","year":"1995","journal-title":"Sociol Methodol"},{"key":"key-10.1136\/oemed-2015-103019-21","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1523\/JNEUROSCI.23-04-01498.2003","article-title":"Behavioral effects of high-strength static magnetic fields on rats","volume":"23","author":"Houpt","year":"2003","journal-title":"J Neurosci"},{"key":"key-10.1136\/oemed-2015-103019-22","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.physbeh.2010.11.028","article-title":"Behavioral effects on rats of motion within a high static magnetic field","volume":"102","author":"Houpt","year":"2011","journal-title":"Physiol Behav"},{"key":"key-10.1136\/oemed-2015-103019-23","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1136\/oem.2006.030031","article-title":"Exposure and dose modelling in occupational epidemiology","volume":"64","author":"Kriebel","year":"2007","journal-title":"Occup Environ Med"}],"container-title":["Occupational and Environmental Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/oemed-2015-103019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T07:21:15Z","timestamp":1601104875000},"score":1,"resource":{"primary":{"URL":"https:\/\/oem.bmj.com\/lookup\/doi\/10.1136\/oemed-2015-103019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,11]]},"references-count":23,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2016,2,16]]},"published-print":{"date-parts":[[2016,3]]}},"alternative-id":["10.1136\/oemed-2015-103019"],"URL":"https:\/\/doi.org\/10.1136\/oemed-2015-103019","relation":{},"ISSN":["1351-0711","1470-7926"],"issn-type":[{"value":"1351-0711","type":"print"},{"value":"1470-7926","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,11]]}}}