{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T09:13:16Z","timestamp":1790673196907,"version":"4.1.0"},"reference-count":41,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2020,2,13]],"date-time":"2020-02-13T00:00:00Z","timestamp":1581552000000},"content-version":"unspecified","delay-in-days":12,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Open Heart"],"accepted":{"date-parts":[[2020,1,7]]},"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>The main objective of the present study was to compare the use of four-dimensional (4D) flow MRI with the habitual sequence (two-dimensional phase-contrast (2DPC) MRI) for the assessment of aortic regurgitation (AR) in the clinical routine.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>This was a retrospective, observational cohort study of patients with varying grades of AR. For the purposes of the present study, we selected all the cases with a regurgitant fraction (RF)&gt;5% as determined by 2DPC MRI (n=34). In all cases, both sequences (2DPC and 4D flow MRI) were acquired in a single session to ensure comparability. We compared the results of the two techniques by evaluating forward flow, regurgitant flow and regurgitation fraction. Then, the patients were divided into subgroups to determine if these factors had any influence on the measurements: aortic diameter (\u2264 vs &gt;38\u2009mm), valve anatomy (tricuspid vs bicuspid\/quadricuspid), stenosis (gradient \u226515\u2009vs &lt;15) and region of interest location (aortic valve vs sinotubular junction).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>No statistically significant differences were observed between the two techniques with Pearson\u2019s correlation coefficients (r) of forward flow (r=0.826\/p value&lt;0001), regurgitant flow (r=0.866\/p value&lt;0001) and RF (r=0.761\/p value&lt;0001).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>The findings of this study confirm the value of 4D flow MRI for grading AR in clinical practice with an excellent correlation with the standard technique (2DPC MRI).<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/openhrt-2019-001158","type":"journal-article","created":{"date-parts":[[2020,2,14]],"date-time":"2020-02-14T04:35:13Z","timestamp":1581654913000},"page":"e001158","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":33,"title":["Clinical use of 4D flow MRI for quantification of aortic regurgitation"],"prefix":"10.1136","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9554-1541","authenticated-orcid":false,"given":"Ana","family":"Alvarez","sequence":"first","affiliation":[{"name":"Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain"},{"name":"Universidad Europea de Madrid, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vicente","family":"Martinez","sequence":"additional","affiliation":[{"name":"Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gonzalo","family":"Pizarro","sequence":"additional","affiliation":[{"name":"Universidad Europea de Madrid, Madrid, Spain"},{"name":"Department of Cardiology, Complejo Hospitalario Ruber Juan Bravo, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Recio","sequence":"additional","affiliation":[{"name":"Imaging Department, Hospital Universitario Quironsalud Madrid, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose \u00c1ngel","family":"Cabrera","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Hospital Universitario Quironsalud Madrid, Madrid, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2020,2,13]]},"reference":[{"key":"2025081710190016000_7.1.e001158.1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehx391"},{"key":"2025081710190016000_7.1.e001158.2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.176857"},{"key":"2025081710190016000_7.1.e001158.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2007.10.008"},{"key":"2025081710190016000_7.1.e001158.4","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.2000.2011"},{"key":"2025081710190016000_7.1.e001158.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2012.06.003"},{"key":"2025081710190016000_7.1.e001158.6","doi-asserted-by":"publisher","DOI":"10.1126\/science.130.3389.1652"},{"key":"2025081710190016000_7.1.e001158.7","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.185.1.1523315"},{"key":"2025081710190016000_7.1.e001158.8","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2586(199901)9:1<119::AID-JMRI16>3.0.CO;2-F"},{"key":"2025081710190016000_7.1.e001158.9","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.112.975623"},{"key":"2025081710190016000_7.1.e001158.10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.111.083600"},{"key":"2025081710190016000_7.1.e001158.11","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.amjcard.2016.12.017","article-title":"Cardiac magnetic resonance imaging versus transthoracic echocardiography for prediction of outcomes in chronic aortic or mitral regurgitation","volume":"119","author":"Harris","year":"2017","journal-title":"Am J Cardiol"},{"key":"2025081710190016000_7.1.e001158.12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12968-015-0174-5","article-title":"4D flow cardiovascular magnetic resonance consensus statement","volume":"17","author":"Dyverfeldt","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.13","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1007\/s10554-016-0938-5","article-title":"Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics","volume":"32","author":"Bollache","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081710190016000_7.1.e001158.14","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s10554-015-0779-7","article-title":"Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography","volume":"32","author":"Chelu","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081710190016000_7.1.e001158.15","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1016\/j.ejrad.2016.07.018","article-title":"Cloud-processed 4D CMR flow imaging for pulmonary flow quantification","volume":"85","author":"Chelu","year":"2016","journal-title":"Eur J Radiol"},{"key":"2025081710190016000_7.1.e001158.16","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12120055"},{"key":"2025081710190016000_7.1.e001158.17","doi-asserted-by":"crossref","first-page":"E90","DOI":"10.1186\/1532-429X-15-S1-E90","article-title":"Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease","volume":"15","author":"Gabbour","year":"2013","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.18","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/s10554-017-1195-y","article-title":"Cardiovascular magnetic resonance imaging to assess myocardial fibrosis in valvular heart disease","volume":"34","author":"Podlesnikar","year":"2018","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081710190016000_7.1.e001158.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2011.05.034"},{"key":"2025081710190016000_7.1.e001158.20","doi-asserted-by":"crossref","first-page":"1884","DOI":"10.3938\/jkps.61.1884","article-title":"Evaluation of aortic regurgitation by using PC MRI: a comparison of the accuracies at different image plane locations","volume":"61","author":"Kim","year":"2012","journal-title":"J Korean Phys Soc"},{"key":"2025081710190016000_7.1.e001158.21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12880-015-0099-3","article-title":"Prospective, randomized comparison of gadopentetate and gadobutrol to assess chronic myocardial infarction applying cardiovascular magnetic resonance","volume":"15","author":"Rudolph","year":"2015","journal-title":"BMC Med Imaging"},{"key":"2025081710190016000_7.1.e001158.22","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e3181ae99b5"},{"key":"2025081710190016000_7.1.e001158.23","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.10092269"},{"key":"2025081710190016000_7.1.e001158.24","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2013.04.025"},{"key":"2025081710190016000_7.1.e001158.25","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1002\/mrm.25466","article-title":"Assessment of altered three-dimensional blood characteristics in aortic disease by velocity distribution analysis","volume":"74","author":"Garcia","year":"2015","journal-title":"Magn Reson Med"},{"key":"2025081710190016000_7.1.e001158.26","doi-asserted-by":"publisher","DOI":"10.1093\/ehjci\/jev228"},{"key":"2025081710190016000_7.1.e001158.27","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1002\/jmri.24962","article-title":"4D flow MRI and T1 -Mapping: Assessment of altered cardiac hemodynamics and extracellular volume fraction in hypertrophic cardiomyopathy","volume":"43","author":"van Ooij","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"2025081710190016000_7.1.e001158.28","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1002\/jmri.25916","article-title":"4D flow MRI, cardiac function, and T\n                  1\n                -mapping: Association of valve-mediated changes in aortic hemodynamics with left ventricular remodeling","volume":"48","author":"Geiger","year":"2018","journal-title":"J Magn Reson Imaging"},{"key":"2025081710190016000_7.1.e001158.29","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/s12968-017-0347-5","article-title":"Longitudinal evaluation of aortic hemodynamics in Marfan syndrome: new insights from a 4D flow cardiovascular magnetic resonance Multi-Year follow-up study","volume":"19","author":"Geiger","year":"2017","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.30","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1148\/radiol.2018180807","article-title":"Automated cardiac valve tracking for flow quantification with four-dimensional flow MRI","volume":"290","author":"Kamphuis","year":"2019","journal-title":"Radiology"},{"key":"2025081710190016000_7.1.e001158.31","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.acra.2014.04.012","article-title":"Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging","volume":"21","author":"Hanneman","year":"2014","journal-title":"Acad Radiol"},{"key":"2025081710190016000_7.1.e001158.32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12968-015-0111-7","article-title":"Normal values for cardiovascular magnetic resonance in adults and children","volume":"17","author":"Kawel-Boehm","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.33","doi-asserted-by":"publisher","DOI":"10.1080\/10976640600604856"},{"key":"2025081710190016000_7.1.e001158.34","doi-asserted-by":"crossref","first-page":"3180","DOI":"10.1007\/s00330-015-4120-6","article-title":"Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding","volume":"26","author":"Chaturvedi","year":"2016","journal-title":"Eur Radiol"},{"key":"2025081710190016000_7.1.e001158.35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12968-016-0277-7","article-title":"Flow measurement at the aortic root - impact of location of through-plane phase contrast velocity mapping","volume":"18","author":"Bertelsen","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.03.047"},{"key":"2025081710190016000_7.1.e001158.37","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.113.000528"},{"key":"2025081710190016000_7.1.e001158.38","doi-asserted-by":"crossref","first-page":"P216","DOI":"10.1186\/1532-429X-17-S1-P216","article-title":"Intraindividual validation of 4D flow measurement against 2D flow measurements in aortas with bicuspid or tricuspid valves by cardiovascular magnetic resonance (CMR)","volume":"17","author":"Kharabish","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.39","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23793"},{"key":"2025081710190016000_7.1.e001158.40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12968-015-0122-4","article-title":"Characterization and quantification of dynamic eccentric regurgitation of the left atrioventricular valve after atrioventricular septal defect correction with 4D flow cardiovascular magnetic resonance and retrospective valve tracking","volume":"17","author":"Calkoen","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081710190016000_7.1.e001158.41","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.11102064"}],"container-title":["Open Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/openhrt-2019-001158","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,17]],"date-time":"2025-08-17T17:19:13Z","timestamp":1755451153000},"score":1,"resource":{"primary":{"URL":"https:\/\/openheart.bmj.com\/lookup\/doi\/10.1136\/openhrt-2019-001158"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,2,13]]},"published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.1136\/openhrt-2019-001158"],"URL":"https:\/\/doi.org\/10.1136\/openhrt-2019-001158","relation":{},"ISSN":["2053-3624"],"issn-type":[{"value":"2053-3624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2]]}}}