{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T19:08:05Z","timestamp":1790708885250,"version":"4.1.0"},"reference-count":34,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T00:00:00Z","timestamp":1594771200000},"content-version":"unspecified","delay-in-days":14,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007460","name":"Arvid Nilssons Fond","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007460","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100012774","name":"Innovationsfonden","doi-asserted-by":"publisher","award":["12-135225"],"award-info":[{"award-number":["12-135225"]}],"id":[{"id":"10.13039\/100012774","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Open Heart"],"accepted":{"date-parts":[[2020,6,9]]},"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>Cardiac MRI is quickly emerging as the gold standard for assessment of mitral regurgitation, most commonly with the indirect method subtracting forward flow in aorta from volumetric segmentation of the left ventricle. We aimed to investigate how aortic flow measurements with increasing distance from the aortic valve affect calculated mitral regurgitations and whether measurements were influenced by breath-hold regimen.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Free-breathing and breath-hold phase contrast flows were measured in aorta at valve level, sinotubular (ST) junction, mid-ascending aorta and in the pulmonary trunk. Flow measurements were pairwise compared, and subsequently, after exclusion of patients with visible mitral and tricuspid regurgitations for left-sided and right-sided comparisons, respectively, flow-measured stroke volumes were compared with ventricular volumetric segmentations.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Thirty-nine participants without arrhythmias or structural abnormalities of the large vessels were included. Stroke volumes measured with free-breathing and breath-hold flow decreased equally with increasing distance to the aortic valves (breath-hold flow: aortic valve 105.6\u00b120.8\u2009mL, ST junction 101.5\u00b120.7\u2009mL, mid-ascending aorta 98.1\u00b121.5\u2009mL). After exclusion of atrioventricular regurgitations, stroke volumes determined by volumetric measurements were higher compared with values determined by flow measurements, corresponding to \u2018false\u2019 atrioventricular regurgitations of 8.0%\u00b15.8% with flow measured at valve level, 11.6%\u00b15.2% at the ST junction and 15.3%\u00b15.0% at the mid-ascending aorta.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Stroke volumes determined by flow decrease throughout the proximal aorta and are systematically lower than volumetrically measured stroke volumes. The indirect method systematically overestimates mitral regurgitations, especially with increasing distance from the aortic valves.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/openhrt-2020-001323","type":"journal-article","created":{"date-parts":[[2020,7,16]],"date-time":"2020-07-16T06:55:20Z","timestamp":1594882520000},"page":"e001323","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Cardiac magnetic resonance systematically overestimates mitral regurgitations by the indirect method"],"prefix":"10.1136","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7852-6537","authenticated-orcid":false,"given":"Litten","family":"Bertelsen","sequence":"first","affiliation":[{"name":"Department of Cardiology, Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niels","family":"Vejlstrup","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Andreasen","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark"},{"name":"Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Morten Salling","family":"Olesen","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark"},{"name":"Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesper Hastrup","family":"Svendsen","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark"},{"name":"Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2020,7,15]]},"reference":[{"key":"2025081711152955000_7.2.e001323.1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.92.5.1151"},{"key":"2025081711152955000_7.2.e001323.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.12.009"},{"key":"2025081711152955000_7.2.e001323.3","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2015-309054"},{"key":"2025081711152955000_7.2.e001323.4","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s10554-012-0047-z","article-title":"Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold","volume":"29","author":"Bolen","year":"2013","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081711152955000_7.2.e001323.5","doi-asserted-by":"publisher","DOI":"10.1093\/ehjci\/jet129"},{"key":"2025081711152955000_7.2.e001323.6","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1186\/s12968-017-0417-8","article-title":"Quantification of mitral regurgitation in patients with hypertrophic cardiomyopathy using aortic and pulmonary flow data: impacts of left ventricular outflow tract obstruction and different left ventricular segmentation methods","volume":"19","author":"\u015apiewak","year":"2017","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081711152955000_7.2.e001323.7","doi-asserted-by":"crossref","first-page":"3180","DOI":"10.1007\/s00330-015-4120-6","article-title":"Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding","volume":"26","author":"Chaturvedi","year":"2016","journal-title":"Eur Radiol"},{"key":"2025081711152955000_7.2.e001323.8","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1186\/s12968-016-0277-7","article-title":"Flow measurement at the aortic root\u2014impact of location of through-plane phase contrast velocity mapping","volume":"18","author":"Bertelsen","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081711152955000_7.2.e001323.9","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1038\/s41569-019-0305-z","article-title":"Assessment of mitral valve regurgitation by cardiovascular magnetic resonance imaging","volume":"17","author":"Garg","year":"2020","journal-title":"Nat Rev Cardiol"},{"key":"2025081711152955000_7.2.e001323.10","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-010-0222-y"},{"key":"2025081711152955000_7.2.e001323.11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.12.047"},{"key":"2025081711152955000_7.2.e001323.12","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-12-32"},{"key":"2025081711152955000_7.2.e001323.13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2016.08.007"},{"key":"2025081711152955000_7.2.e001323.14","doi-asserted-by":"crossref","DOI":"10.1186\/s12880-016-0128-x","article-title":"Phase-contrast MRI volume flow\u2014a comparison of breath held and navigator based acquisitions","volume":"16","author":"Andersson","year":"2016","journal-title":"BMC Med Imaging"},{"key":"2025081711152955000_7.2.e001323.15","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/s00247-013-2830-y","article-title":"Analysis of an automated background correction method for cardiovascular MR phase contrast imaging in children and young adults","volume":"44","author":"Rigsby","year":"2014","journal-title":"Pediatr Radiol"},{"key":"2025081711152955000_7.2.e001323.16","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2292020559"},{"key":"2025081711152955000_7.2.e001323.17","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2594(200102)45:2<346::AID-MRM1044>3.0.CO;2-I"},{"key":"2025081711152955000_7.2.e001323.18","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2012.04.052"},{"key":"2025081711152955000_7.2.e001323.19","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20361"},{"key":"2025081711152955000_7.2.e001323.20","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21395"},{"key":"2025081711152955000_7.2.e001323.21","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"2025081711152955000_7.2.e001323.22","doi-asserted-by":"publisher","DOI":"10.1093\/ehjci\/jev321"},{"key":"2025081711152955000_7.2.e001323.23","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.115.017888"},{"key":"2025081711152955000_7.2.e001323.24","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.117.029332"},{"key":"2025081711152955000_7.2.e001323.25","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1186\/s12968-016-0282-x","article-title":"Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance","volume":"18","author":"D'Errico","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081711152955000_7.2.e001323.26","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(02)02381-0"},{"key":"2025081711152955000_7.2.e001323.27","doi-asserted-by":"crossref","DOI":"10.1186\/s12880-017-0238-0","article-title":"Cardiovascular magnetic resonance in the evaluation of heart valve disease","volume":"17","author":"Gulsin","year":"2017","journal-title":"BMC Med Imaging"},{"key":"2025081711152955000_7.2.e001323.28","doi-asserted-by":"publisher","DOI":"10.1080\/10976640701465090"},{"key":"2025081711152955000_7.2.e001323.29","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.22.3.g02ma11651"},{"key":"2025081711152955000_7.2.e001323.30","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s10554-018-1441-y","article-title":"CMR quantitation of change in mitral regurgitation following transcatheter aortic valve replacement (TAVR): impact on left ventricular reverse remodeling and outcome","volume":"35","author":"Chew","year":"2019","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081711152955000_7.2.e001323.31","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23793"},{"key":"2025081711152955000_7.2.e001323.32","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.ijcard.2017.07.023","article-title":"Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: a systematic review","volume":"249","author":"Crandon","year":"2017","journal-title":"Int J Cardiol"},{"key":"2025081711152955000_7.2.e001323.33","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1007\/s10554-016-0938-5","article-title":"Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics","volume":"32","author":"Bollache","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"2025081711152955000_7.2.e001323.34","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10029"}],"container-title":["Open Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/openhrt-2020-001323","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,17]],"date-time":"2025-08-17T18:15:38Z","timestamp":1755454538000},"score":1,"resource":{"primary":{"URL":"https:\/\/openheart.bmj.com\/lookup\/doi\/10.1136\/openhrt-2020-001323"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":34,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020,7,15]]},"published-print":{"date-parts":[[2020,7]]}},"alternative-id":["10.1136\/openhrt-2020-001323"],"URL":"https:\/\/doi.org\/10.1136\/openhrt-2020-001323","relation":{},"ISSN":["2053-3624"],"issn-type":[{"value":"2053-3624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7]]}}}