{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T00:53:03Z","timestamp":1760921583455,"version":"3.44.0"},"reference-count":32,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T00:00:00Z","timestamp":1633824000000},"content-version":"unspecified","delay-in-days":9,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Open Heart"],"accepted":{"date-parts":[[2021,9,22]]},"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:p>Nowadays, technological progress has equipped clinicians with new useful devices for the collection, analysis and presentation of data. As a consequence, many diseases and pathological conditions have been studied in a more detailed way, sometimes with remarkable results. In fact, they are not always validated by the old physiological models. In this respect, we present the case of low gradient severe aortic stenosis, a condition characterised by a small aortic valve area and a low-pressure gradient. According to the mathematical and physical assumptions these readings are contradictory whereas the Doppler-echocardiography shows clearly the existence of such a situation. In this work, we have described the physiological base of this phenomenon and discussed the limitations of the technology used. In this work, we are going to analyse some conditions commonly observed in daily clinical practice in order to prompt a critical outlook in both clinicians and technicians about the instrumentations used and the methods applied.<\/jats:p>","DOI":"10.1136\/openhrt-2021-001746","type":"journal-article","created":{"date-parts":[[2021,10,11]],"date-time":"2021-10-11T15:04:56Z","timestamp":1633964696000},"page":"e001746","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of low gradient severe aortic stenosis: should we change our outlook in the analysis of clinical data?"],"prefix":"10.1136","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2078-1978","authenticated-orcid":false,"given":"Ivan","family":"Corazza","sequence":"first","affiliation":[{"name":"Department of Experimental Diagnostic and Specialty Medicine, Alma Mater Studiorum University of Bologna, Bologna, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Margherita","family":"Zecchi","sequence":"additional","affiliation":[{"name":"Department of Experimental Diagnostic and Specialty Medicine, Alma Mater Studiorum University of Bologna, Bologna, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Romano","family":"Zannoli","sequence":"additional","affiliation":[{"name":"Department of Experimental Diagnostic and Specialty Medicine, Alma Mater Studiorum University of Bologna, Bologna, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2021,10,11]]},"reference":[{"key":"2025081711061557000_8.2.e001746.1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw096"},{"key":"2025081711061557000_8.2.e001746.2","doi-asserted-by":"crossref","DOI":"10.1007\/s11886-013-0431-x","article-title":"Paradoxical low flow aortic valve stenosis: incidence, evaluation, and clinical significance","volume":"16","author":"Clavel","year":"2014","journal-title":"Curr Cardiol Rep"},{"key":"2025081711061557000_8.2.e001746.3","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.005718"},{"key":"2025081711061557000_8.2.e001746.4","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(09)60211-7"},{"key":"2025081711061557000_8.2.e001746.5","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00200-3"},{"key":"2025081711061557000_8.2.e001746.6","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(51)90002-6"},{"key":"2025081711061557000_8.2.e001746.7","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.amjmed.2016.10.005","article-title":"Aortic stenosis: pathophysiology, diagnosis, and therapy","volume":"130","author":"Joseph","year":"2017","journal-title":"Am J Med"},{"key":"2025081711061557000_8.2.e001746.8","doi-asserted-by":"crossref","unstructured":"Bashford GR . Ultrasonic measurement of blood flow velocity and applications for cardiovascular assessments. In: Patel VB , Preedy VR , eds. Biomarkers in cardiovascular disease. Dordrecht: Springer Netherlands, 2015: 1\u201331.","DOI":"10.1007\/978-94-007-7741-5_18-1"},{"key":"2025081711061557000_8.2.e001746.9","first-page":"590","article-title":"[Indications for cardiology consultation and management of cardiac patients who will undergo surgical or endoscopic procedures: the proposal of the University Hospital of Trieste, Italy]","volume":"2006","author":"Massa","year":"2010","journal-title":"G Ital Cardiol"},{"key":"2025081711061557000_8.2.e001746.10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.183095"},{"key":"2025081711061557000_8.2.e001746.11","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1081\/JCMR-200065639","article-title":"How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping","volume":"7","author":"Chai","year":"2005","journal-title":"J Cardiovasc Magn Reson"},{"key":"2025081711061557000_8.2.e001746.12","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1148\/rg.2020190039","article-title":"Phase-contrast MRI: physics, techniques, and clinical applications","volume":"40","author":"Wymer","year":"2020","journal-title":"Radiographics"},{"key":"2025081711061557000_8.2.e001746.13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.echo.2017.10.004","article-title":"Quantification of aortic valve regurgitation by pulsed Doppler examination of the left subclavian artery velocity contour: a validation study with cardiovascular magnetic resonance imaging","volume":"31","author":"Spampinato","year":"2018","journal-title":"J Am Soc Echocardiogr"},{"key":"2025081711061557000_8.2.e001746.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2014.04.021"},{"key":"2025081711061557000_8.2.e001746.15","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1243\/0954411991534951","article-title":"Measurements of organ volume by ultrasonography","volume":"213","author":"Gilja","year":"1999","journal-title":"Proc Inst Mech Eng H"},{"key":"2025081711061557000_8.2.e001746.16","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90454-U"},{"key":"2025081711061557000_8.2.e001746.17","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.89.1.116"},{"key":"2025081711061557000_8.2.e001746.18","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.002310"},{"key":"2025081711061557000_8.2.e001746.19","doi-asserted-by":"crossref","DOI":"10.1186\/s12880-017-0238-0","article-title":"Cardiovascular magnetic resonance in the evaluation of heart valve disease","volume":"17","author":"Gulsin","year":"2017","journal-title":"BMC Med Imaging"},{"key":"2025081711061557000_8.2.e001746.20","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1002\/jmri.26847","article-title":"Clinical assessment of aortic valve stenosis: comparison between 4D flow MRI and transthoracic echocardiography","volume":"51","author":"Adriaans","year":"2020","journal-title":"J Magn Reson Imaging"},{"key":"2025081711061557000_8.2.e001746.21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2018.10.034"},{"key":"2025081711061557000_8.2.e001746.22","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.89.2.827"},{"key":"2025081711061557000_8.2.e001746.23","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.67.2.193"},{"key":"2025081711061557000_8.2.e001746.24","first-page":"740","article-title":"Physiological basis of flow dependence of Gorlin formula valve area in aortic stenosis: analysis using an hydraulic model of pulsatile flow","volume":"9","author":"Rifkin","year":"2000","journal-title":"J Heart Valve Dis"},{"key":"2025081711061557000_8.2.e001746.25","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00060-0"},{"key":"2025081711061557000_8.2.e001746.26","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90079-3"},{"key":"2025081711061557000_8.2.e001746.27","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1093\/ehjci\/jew335","article-title":"Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography","volume":"18","author":"Baumgartner","year":"2017","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2025081711061557000_8.2.e001746.28","unstructured":"Combining Automatic Angle Correction and 3-D Tracking Doppler for the Assessment of Aortic Stenosis Severity - PubMed. Available: https:\/\/pubmed.ncbi.nlm.nih.gov\/31180850\/ [Accessed 12 May 2021]."},{"key":"2025081711061557000_8.2.e001746.29","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.carrev.2018.04.002","article-title":"The evolving approach to the evaluation of low-gradient aortic stenosis","volume":"20","author":"Cutting","year":"2019","journal-title":"Cardiovasc Revasc Med"},{"key":"2025081711061557000_8.2.e001746.30","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.63.5.1050"},{"key":"2025081711061557000_8.2.e001746.31","first-page":"353","article-title":"Comparison between the Gorlin formula and a simplified formula to measure the severity of pulmonic stenosis","volume":"9","author":"Hare","year":"1983","journal-title":"Cathet Cardiovasc Diagn"},{"key":"2025081711061557000_8.2.e001746.32","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.119.014717","article-title":"Deep learning-based algorithm for detecting aortic stenosis using electrocardiography","volume":"9","author":"Kwon","year":"2020","journal-title":"J Am Heart Assoc"}],"container-title":["Open Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/openhrt-2021-001746","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,17]],"date-time":"2025-08-17T18:06:25Z","timestamp":1755453985000},"score":1,"resource":{"primary":{"URL":"https:\/\/openheart.bmj.com\/lookup\/doi\/10.1136\/openhrt-2021-001746"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,10,11]]},"published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.1136\/openhrt-2021-001746"],"URL":"https:\/\/doi.org\/10.1136\/openhrt-2021-001746","relation":{},"ISSN":["2053-3624"],"issn-type":[{"type":"electronic","value":"2053-3624"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}