{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T16:17:19Z","timestamp":1784564239122,"version":"3.55.0"},"reference-count":28,"publisher":"BMJ","issue":"1","license":[{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"unspecified","delay-in-days":34,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Open Heart"],"accepted":{"date-parts":[[2026,1,15]]},"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Guidelines permit up to 360 J for synchronised biphasic electrical cardioversion (ECV) in atrial fibrillation (AF) lasting &gt;48\u2009hours. The CHESS randomised trial reported higher first-shock success with fixed 360\u202fJ versus a low-escalation 125\u2013150\u2013200\u202fJ sequence. Much of this evidence used adhesive pads without manual pressure and anterior\u2013posterior positioning. We evaluated a 200 J-first, fixed-escalation biphasic ECV protocol delivered with a standardised technique in an emergency department (ED).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Single-centre retrospective observational study of consecutive adults undergoing elective ECV for symptomatic AF &gt;48\u202fhours (2019\u20132021). Procedures used hand-held paddles with firm chest pressure in the anterolateral (AL) position under deep sedation. The predefined sequence was 200\u2192300\u2192360\u202fJ if needed. The primary outcome was restoration of sinus rhythm (SR) documented on a 12-lead ECG within 120\u2009min. Secondary outcomes were first shock success at 200 J, cumulative efficacy, SR to discharge without post-ECV antiarrhythmics, adverse events and subgroup efficacy. Results were contrasted descriptively with 360 J-first cohorts (CHESS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Of 451 ECV procedures identified, 374 were eligible. The primary outcome was achieved in 97.3% (364\/374; 95% CI 95.5 to 98.7). First-shock success with 200 J was 88.0% (329\/374; 95%\u2009CI 84.3 to 90.9). Escalation to 300 J and 360 J was required in 44 and 15\u2009patients. SR was maintained to discharge in converted patients. Two minor adverse events occurred (2\/374, 0.5%) and no serious adverse events were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>A 200 J-first, fixed-escalation biphasic protocol with a standardised technique (manual paddles, firm pressure, AL placement) achieved high first-shock and excellent cumulative efficacy for AF&gt;48\u2009hours in real-world ED care without routine pharmacologic adjuncts. Findings support considering a 200 J-first approach and motivate pragmatic multicentre randomised controlled trials directly comparing 200 J-first versus 360 J-first under harmonised technique with objective safety endpoints.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/openhrt-2025-003875","type":"journal-article","created":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T14:55:32Z","timestamp":1770216932000},"page":"e003875","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["200 J-first, fixed-escalation biphasic electrical cardioversion for atrial fibrillation &gt;48 hours in the emergency department: a single-centre retrospective observational study"],"prefix":"10.1136","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8765-233X","authenticated-orcid":false,"given":"Jakub","family":"Nozewski","sequence":"first","affiliation":[{"name":"Emergency Medicine, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8033-3977","authenticated-orcid":false,"given":"Zbigniew","family":"Siudak","sequence":"additional","affiliation":[{"name":"Jan Kochanowski University, Kielce, Swietokrzyskie, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbra E","family":"Backus","sequence":"additional","affiliation":[{"name":"Emergency Medicine, LUMC, Leiden, Zuid-Holland, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aristomenis","family":"Exadaktylos","sequence":"additional","affiliation":[{"name":"Emergency Medicine, Faculty of Medicine, University of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,2,4]]},"reference":[{"key":"2026020406551855000_13.1.e003875.1","doi-asserted-by":"crossref","unstructured":"Hindricks G , Potpara T , Dagres N , et al . ESC Scientific Document Group. Eur Heart J 2020. doi:10.1093\/eurheartj\/ehaa612","DOI":"10.1093\/eurheartj\/ehaa612"},{"key":"2026020406551855000_13.1.e003875.2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw210"},{"key":"2026020406551855000_13.1.e003875.3","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCRESAHA.120.316340"},{"key":"2026020406551855000_13.1.e003875.4","doi-asserted-by":"crossref","DOI":"10.1016\/j.lanepe.2023.100786","article-title":"Atrial fibrillation: epidemiology, screening and digital health","volume":"37","author":"Linz","year":"2024","journal-title":"Lancet Reg Health Eur"},{"key":"2026020406551855000_13.1.e003875.5","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1016\/j.hroo.2025.06.017","article-title":"Atrial fibrillation in the emergency department: Predictors of admission and discharge-A nationwide analysis","volume":"6","author":"Millhuff","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"2026020406551855000_13.1.e003875.6","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.118.009024","article-title":"Emergency Department Visits for Atrial Fibrillation in the United States: Trends in Admission Rates and Economic Burden From 2007 to 2014","volume":"7","author":"Rozen","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"2026020406551855000_13.1.e003875.7","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2021-211572"},{"key":"2026020406551855000_13.1.e003875.8","doi-asserted-by":"crossref","DOI":"10.3390\/jcm13010190","article-title":"Impact of Various Atrial Fibrillation Treatment Strategies on Length of Stay in the Emergency Department and Early Complications-3 Years of a Single-Center Experience","volume":"13","author":"K\u0142osiewicz","year":"2023","journal-title":"J Clin Med"},{"key":"2026020406551855000_13.1.e003875.9","doi-asserted-by":"crossref","DOI":"10.3390\/jcm14196845","article-title":"Pharmacological Cardioversion Versus Electrical Cardioversion in the Acute Treatment of Atrial Fibrillation in the Emergency Department: The Recufa-Hula Register","volume":"14","author":"L\u00f3pez-D\u00edaz","year":"2025","journal-title":"J Clin Med"},{"key":"2026020406551855000_13.1.e003875.10","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1093\/europace\/euac199","article-title":"Techniques improving electrical cardioversion success for patients with atrial fibrillation: a systematic review and meta-analysis","volume":"25","author":"Nguyen","year":"2023","journal-title":"Europace"},{"key":"2026020406551855000_13.1.e003875.11","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1093\/europace\/euad009","article-title":"A stepwise external cardioversion protocol for atrial fibrillation to maximize acute success rate","volume":"25","author":"Darrat","year":"2023","journal-title":"Europace"},{"key":"2026020406551855000_13.1.e003875.12","doi-asserted-by":"crossref","DOI":"10.1186\/s13063-023-07230-2","article-title":"Clinical decision support to Optimize Care of patients with Atrial Fibrillation or flutter in the Emergency department: protocol of a stepped-wedge cluster randomized pragmatic trial (O\u2019CAF\u00c9 trial)","volume":"24","author":"Vinson","year":"2023","journal-title":"Trials"},{"key":"2026020406551855000_13.1.e003875.13","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehz585"},{"key":"2026020406551855000_13.1.e003875.14","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.pcad.2025.06.009","article-title":"Strategies for optimizing efficacy of electrical cardioversion of atrial fibrillation","volume":"91","author":"Bharwani","year":"2025","journal-title":"Prog Cardiovasc Dis"},{"key":"2026020406551855000_13.1.e003875.15","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1111\/pace.12937","article-title":"Effect of Applying Force to Self-Adhesive Electrodes on Transthoracic Impedance: Implications for Electrical Cardioversion","volume":"39","author":"Ramirez","year":"2016","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026020406551855000_13.1.e003875.16","doi-asserted-by":"crossref","first-page":"2207","DOI":"10.1016\/j.jacep.2024.05.037","article-title":"Manual Chest PRESSURE During Direct Current Cardioversion for Atrial Fibrillation: A Randomized Control Trial (PRESSURE-AF)","volume":"10","author":"Ferreira","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026020406551855000_13.1.e003875.17","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.110.960591"},{"key":"2026020406551855000_13.1.e003875.18","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0162245","article-title":"Evidence for Acute Myocardial and Skeletal Muscle Injury after Serial Transthoracic Shocks in Healthy Swine","volume":"11","author":"Guensch","year":"2016","journal-title":"PLoS One"},{"key":"2026020406551855000_13.1.e003875.19","article-title":"Evaluation of Changes in Cardiac Troponin I Levels After Direct Current Cardioversion in Patients With Atrial Fibrillation","volume":"16","author":"Katerini","year":"2024","journal-title":"Cureus"},{"key":"2026020406551855000_13.1.e003875.20","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jjcc.2018.01.016","article-title":"Impact of internal and external electrical cardioversion on cardiac specific enzymes and inflammation in patients with atrial fibrillation and heart failure","volume":"72","author":"Stieger","year":"2018","journal-title":"J Cardiol"},{"key":"2026020406551855000_13.1.e003875.21","doi-asserted-by":"crossref","unstructured":"Fischer K , Riecker C , Overney S , et al . Visualizing myocardial injury from elective cardioversion with CMR. Eur Heart J Cardiovasc Imaging 2021;22. doi:10.1093\/ehjci\/jeaa356.310","DOI":"10.1093\/ehjci\/jeaa356.310"},{"key":"2026020406551855000_13.1.e003875.22","first-page":"2130","article-title":"Optimizing Energy Delivery in Cardioversion: A Randomized PROTOCOLENERGYTrial of 2 Different Algorithms in Patients With Atrial Fibrillation","volume":"40","author":"Roman","year":"2024","journal-title":"Can J Cardiol"},{"key":"2026020406551855000_13.1.e003875.23","doi-asserted-by":"crossref","DOI":"10.3390\/s22072808","article-title":"A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation","volume":"22","author":"Heyer","year":"2022","journal-title":"Sensors (Basel)"},{"key":"2026020406551855000_13.1.e003875.24","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2023-002456","article-title":"Electrical energy by electrode placement for cardioversion of atrial fibrillation: a systematic review and meta-analysis","volume":"10","author":"Vinter","year":"2023","journal-title":"Open Heart"},{"key":"2026020406551855000_13.1.e003875.25","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1016\/j.hlc.2022.08.016","article-title":"Anteroposterior Versus Anterolateral Electrode Position for Direct Current Cardioversion of Atrial Fibrillation: A Meta-Analysis of Randomised Controlled Trials","volume":"31","author":"Virk","year":"2022","journal-title":"Heart Lung Circ"},{"key":"2026020406551855000_13.1.e003875.26","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1002\/clc.23987","article-title":"Anteriolateral versus anterior-posterior electrodes in external cardioversion of atrial fibrillation: A systematic review and meta-analysis of clinical trials","volume":"46","author":"Motawea","year":"2023","journal-title":"Clin Cardiol"},{"key":"2026020406551855000_13.1.e003875.27","doi-asserted-by":"crossref","first-page":"1995","DOI":"10.1161\/CIRCULATIONAHA.121.056301","article-title":"Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation","volume":"144","author":"Schmidt","year":"2021","journal-title":"Circulation"},{"key":"2026020406551855000_13.1.e003875.28","doi-asserted-by":"publisher","DOI":"10.1111\/jce.13786"}],"container-title":["Open Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/openhrt-2025-003875","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T14:55:36Z","timestamp":1770216936000},"score":1,"resource":{"primary":{"URL":"https:\/\/openheart.bmj.com\/lookup\/doi\/10.1136\/openhrt-2025-003875"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2,4]]},"published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1136\/openhrt-2025-003875"],"URL":"https:\/\/doi.org\/10.1136\/openhrt-2025-003875","relation":{},"ISSN":["2053-3624"],"issn-type":[{"value":"2053-3624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]}}}