{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T11:06:59Z","timestamp":1789556819772,"version":"build-2803163510"},"reference-count":21,"publisher":"BMJ","issue":"2","license":[{"start":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:00:00Z","timestamp":1783555200000},"content-version":"unspecified","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Open Heart"],"accepted":{"date-parts":[[2026,5,30]]},"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Invasive procedures, including endomyocardial biopsy (EMB), right heart catheterisation (RHC) and coronary angiography (CA), are essential components of graft surveillance after heart transplantation (HTx). Fluoroscopy remains the primary imaging modality. Data on patient radiation exposure in HTx recipients are limited. The aim of this study was to investigate the kerma-area product (KAP, Gy.cm\n                      <jats:sup>2<\/jats:sup>\n                      ), peak skin dose (PSD, Gy) and fluoroscopy time (s) in these procedures, assess trends in patient radiation exposure over time and identify the procedures contributing most to cumulative radiation during post-transplant surveillance.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Retrospective cohort study at a tertiary care centre including patients who underwent HTx between January 2018 and December 2019. All patients were followed through their invasive organ surveillance period with a median follow-up time of 4.9 years. For the primary end point, KAP (Gy.cm\n                      <jats:sup>2<\/jats:sup>\n                      ), PSD (Gy) and fluoroscopy time (s) were assessed. Secondary end points were procedural success rate and procedure-related complications.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 382 procedures were performed: 330 EMB (86.4%), 22 EMB+RHC (5.8%), 30 EMB+CA with or without RHC (7.8%). The mean annual KAP from fluoroscopic procedures per patient was 50.9\u00b13.95 Gy.cm\n                      <jats:sup>2<\/jats:sup>\n                      in the first post-transplant year, dropping to 11.1\u00b16.1 Gy.cm\n                      <jats:sup>2<\/jats:sup>\n                      by year 5 (p&lt;0.001). By day 387 after HTx, 50% of the total dose was reached. CA was the primary contributor to radiation peaks beyond year 1. Radiation per EMB procedure decreased significantly over time (p=0.002). Procedural success rate was 98.2%, with a 1.0% complication rate.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Radiation exposure is highest in the first-year post-HTx, with CA contributing most to later peaks. Time-specific and procedure-specific strategies are warranted to minimise exposure and optimise long-term care.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/openhrt-2026-004157","type":"journal-article","created":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T11:05:26Z","timestamp":1783595126000},"page":"e004157","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Patient radiation exposure during invasive graft surveillance after heart transplantation"],"prefix":"10.1136","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-6361-7783","authenticated-orcid":false,"given":"Lorraine","family":"Sazgary","sequence":"first","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleni Theano","family":"Samara","sequence":"additional","affiliation":[{"name":"Radiation Protection Unit, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fran","family":"Mikulicic","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"Frank","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dana\u00eb","family":"Parianos","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4065-6747","authenticated-orcid":false,"given":"Matthias P","family":"N\u00e4gele","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"},{"name":"Department of Internal Medicine, Kantonsspital Glarus, Glarus, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Ruschitzka","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"},{"name":"Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas J","family":"Flammer","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ardan M","family":"Saguner","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Zurich, Zurich, Switzerland"},{"name":"Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,7,9]]},"reference":[{"key":"2026091603501097000_13.2.e004157.1","doi-asserted-by":"crossref","first-page":"4944","DOI":"10.1093\/eurheartj\/ehab517","article-title":"Improving survival after heart transplantation despite increasing complexity","volume":"42","author":"Mancini","year":"2021","journal-title":"Eur Heart J"},{"key":"2026091603501097000_13.2.e004157.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2015.10.023"},{"key":"2026091603501097000_13.2.e004157.3","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehab368"},{"key":"2026091603501097000_13.2.e004157.4","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.healun.2022.10.015","article-title":"The International Society for Heart and Lung Transplantation (ISHLT) guidelines for the care of heart transplant recipients","volume":"42","author":"Velleca","year":"2023","journal-title":"J Heart Lung Transplant"},{"key":"2026091603501097000_13.2.e004157.5","doi-asserted-by":"crossref","unstructured":"Sazgary L , Samara ET , St\u00fcssi A , et al . Clinical radiation audits as a tool for the optimization of radiation exposure in cardiac electrophysiology procedures. Zeitschrift F\u00fcr Medizinische Physik 2025;25. doi:10.1016\/j.zemedi.2025.04.003","DOI":"10.1016\/j.zemedi.2025.04.003"},{"key":"2026091603501097000_13.2.e004157.6","doi-asserted-by":"crossref","first-page":"2046","DOI":"10.1016\/j.hrthm.2024.04.060","article-title":"Impact of clinical radiation audits on patient radiation exposure in cardiac implantable electronic device procedures","volume":"21","author":"Sazgary","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026091603501097000_13.2.e004157.7","doi-asserted-by":"crossref","first-page":"4053","DOI":"10.57187\/s.4053","article-title":"Local diagnostic reference levels for cardiac implantable electronic device procedures: data from a tertiary care centre","volume":"155","author":"Samara","year":"2025","journal-title":"Swiss Med Wkly"},{"key":"2026091603501097000_13.2.e004157.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.icrp.2007.10.003]"},{"key":"2026091603501097000_13.2.e004157.9","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2010.09.010"},{"key":"2026091603501097000_13.2.e004157.10","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/eht394"},{"key":"2026091603501097000_13.2.e004157.11","first-page":"80","article-title":"Pediatric patient radiation dosage during endomyocardial biopsies and right heart catheterization using a standard \u201cALARA\u201d radiation reduction protocol in the modern fluoroscopic Era","volume":"83","author":"Sutton","year":"2014","journal-title":"Cathet Cardio Intervent"},{"key":"2026091603501097000_13.2.e004157.12","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1007\/s00246-016-1514-4","article-title":"Reducing Fluoroscopic Radiation Exposure During Endomyocardial Biopsy in Pediatric Transplant Recipients","volume":"38","author":"Gossett","year":"2017","journal-title":"Pediatr Cardiol"},{"key":"2026091603501097000_13.2.e004157.13","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.cardfail.2022.09.005","article-title":"Physician Radiation Exposure During Endomyocardial Biopsy and Right Heart Catheterization","volume":"29","author":"Loyaga-Rendon","year":"2023","journal-title":"J Card Fail"},{"key":"2026091603501097000_13.2.e004157.14","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.ejmp.2021.02.016","article-title":"Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol","volume":"82","author":"Dabin","year":"2021","journal-title":"Phys Med"},{"key":"2026091603501097000_13.2.e004157.15","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.119.007791","article-title":"Safety and Risk of Major Complications With Diagnostic Cardiac Catheterization","volume":"12","author":"Al-Hijji","year":"2019","journal-title":"Circ Cardiovasc Interv"},{"key":"2026091603501097000_13.2.e004157.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.transproceed.2011.03.010"},{"key":"2026091603501097000_13.2.e004157.17","doi-asserted-by":"publisher","DOI":"10.2307\/2286407"},{"key":"2026091603501097000_13.2.e004157.18","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20200018","article-title":"Primary operator radiation dose in the cardiac catheter laboratory","volume":"93","author":"Crowhurst","year":"2020","journal-title":"Br J Radiol"},{"key":"2026091603501097000_13.2.e004157.19","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2008.162420"},{"key":"2026091603501097000_13.2.e004157.20","doi-asserted-by":"crossref","DOI":"10.1186\/s12872-017-0474-9","article-title":"Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)","volume":"17","author":"Carpeggiani","year":"2017","journal-title":"BMC Cardiovasc Disord"},{"key":"2026091603501097000_13.2.e004157.21","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-6143.2008.02196.x"}],"container-title":["Open Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/openhrt-2026-004157","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T10:50:21Z","timestamp":1789555821000},"score":1,"resource":{"primary":{"URL":"https:\/\/openheart.bmj.com\/lookup\/doi\/10.1136\/openhrt-2026-004157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":21,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,7,9]]},"published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1136\/openhrt-2026-004157"],"URL":"https:\/\/doi.org\/10.1136\/openhrt-2026-004157","relation":{},"ISSN":["2053-3624"],"issn-type":[{"value":"2053-3624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]}}}