{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:02:00Z","timestamp":1784592120094,"version":"3.55.0"},"reference-count":30,"publisher":"BMJ","issue":"4","funder":[{"name":"Impact Accelerator Fund, University of Hull.","award":["Not applicable"],"award-info":[{"award-number":["Not applicable"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["BMJ Support Palliat Care"],"accepted":{"date-parts":[[2023,8,21]]},"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:sec>\n<jats:title>Objectives<\/jats:title>\n<jats:p>Facial airflow from a hand-held fan may reduce breathlessness severity and hasten postexertion recovery. Data from randomised controlled trials are limited and the optimal airflow speed remains unknown. We aimed to determine the effect of different airflow speeds on recovery from exercise-induced breathlessness.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>A prospective, randomised, cross-over design. Ten healthy participants (seven male; mean age 29\u00b14\u2009years; height 175\u00b19\u2009cm; body mass 76.9\u00b114.1\u2009kg) completed six bouts of 4\u2009min of exercise. During the first 5\u2009min of a 20\u2009min recovery phase, participants received one of five airflow speeds by holding a fan ~15\u2009cm from their face, or no fan control, administered in random order. Fan A had an internal blade, and fan B had an external blade. Breathlessness was measured using a numerical rating scale (NRS) at minute intervals for the first 10\u2009min, and facial skin temperature was recorded using a thermal imaging camera (immediately postexertion and 5\u2009min recovery).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>\nNine participants completed the trial. A significant main effect for airflow speed (p=0.016, \u03b7p\n<jats:sup>2<\/jats:sup>\n=0.285) and interaction effect for airflow speed over time (p=0.008, \u03b7p\n<jats:sup>2<\/jats:sup>\n=0.167) suggest that the airflow speed modifies breathlessness during recovery from exercise. Fan speeds of 1.7 m\/s or greater increased the speed of recovery from breathlessness compared with control (p&lt;0.05) with the highest airflow speeds (2.5 m\/s and 3.3 m\/s) giving greatest facial cooling.\n<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>Higher airflow rates (1.7 m\/s or greater) reduced self-reported recovery times from exercise-induced breathlessness and reduced facial temperature .<\/jats:p>\n<\/jats:sec>","DOI":"10.1136\/spcare-2023-004309","type":"journal-article","created":{"date-parts":[[2023,9,5]],"date-time":"2023-09-05T17:20:43Z","timestamp":1693934443000},"page":"442-448","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":8,"title":["Airflow rates and breathlessness recovery from submaximal exercise in healthy adults: prospective, randomised, cross-over study"],"prefix":"10.1136","volume":"14","author":[{"given":"Andrew","family":"Brew","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7636-6015","authenticated-orcid":false,"given":"Sarah","family":"O\u2019Beirne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6204-9158","authenticated-orcid":false,"given":"Miriam J","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Ramsenthaler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J","family":"Watson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip A","family":"Rubini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J","family":"Fagan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7723-5244","authenticated-orcid":false,"given":"Flavia","family":"Swan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0480-1134","authenticated-orcid":false,"given":"Andrew","family":"Simpson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2023,9,5]]},"reference":[{"key":"2024112006050962000_14.4.442.1","unstructured":"Scholes S . Health survey for England 2016 physical activity in adults [NHS Digital 2017], Available: http:\/\/healthsurvey.hscic.gov.uk\/media\/63730\/HSE16-Adult-phy-act.pdf [Accessed 9 May 2022]."},{"key":"2024112006050962000_14.4.442.2","first-page":"1","article-title":"Physical inactivity: the biggest public health problem of the 21st century","volume":"43","author":"Blair","year":"2009","journal-title":"Br J Sports Med"},{"key":"2024112006050962000_14.4.442.3","doi-asserted-by":"publisher","DOI":"10.4085\/1062-6050-49.3.27"},{"key":"2024112006050962000_14.4.442.4","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/136.1.58"},{"key":"2024112006050962000_14.4.442.5","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1111\/cpf.12612","article-title":"Effects of postexercise cooling on heart rate recovery in normotensive and hypertensive men","volume":"40","author":"Pe\u00e7anha","year":"2020","journal-title":"Clin Physiol Funct Imaging"},{"key":"2024112006050962000_14.4.442.6","doi-asserted-by":"crossref","DOI":"10.1186\/1471-2458-11-33","article-title":"Predictors of chronic breathlessness: a large population study","volume":"11","author":"Bowden","year":"2011","journal-title":"BMC Public Health"},{"key":"2024112006050962000_14.4.442.7","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1038\/s41533-021-00254-8","article-title":"Targeting exertional breathlessness to improve physical activity: the role of primary care","volume":"31","author":"Rom\u00e1n-Rodr\u00edguez","year":"2021","journal-title":"NPJ Prim Care Respir Med"},{"key":"2024112006050962000_14.4.442.8","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1177\/0269216319835393","article-title":"Airflow relieves chronic breathlessness in people with advanced disease: an exploratory systematic review and meta-analyses","volume":"33","author":"Swan","year":"2019","journal-title":"Palliat Med"},{"key":"2024112006050962000_14.4.442.9","doi-asserted-by":"crossref","unstructured":"Luckett T , Phillips J , Johnson MJ , et al . Contributions of a hand-held fan to self-management of chronic breathlessness. Eur Respir J 2017;50. doi:10.1183\/13993003.00262-2017","DOI":"10.1183\/13993003.00262-2017"},{"key":"2024112006050962000_14.4.442.10","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1007\/s00408-015-9780-0","article-title":"Air current applied to the face improves exercise performance in patients with COPD","volume":"193","author":"Marchetti","year":"2015","journal-title":"Lung"},{"key":"2024112006050962000_14.4.442.11","doi-asserted-by":"publisher","DOI":"10.1136\/bmjspcare-2018-001749"},{"key":"2024112006050962000_14.4.442.12","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1016\/j.jpainsymman.2019.02.017","article-title":"The hand-held fan and the calming hand for people with chronic breathlessness: a feasibility trial","volume":"57","author":"Swan","year":"2019","journal-title":"J Pain Symptom Manage"},{"key":"2024112006050962000_14.4.442.13","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2014-007535","article-title":"Magnetoencephalography to investigate central perception of exercise-induced breathlessness in people with chronic lung disease: a feasibility pilot","volume":"5","author":"Johnson","year":"2015","journal-title":"BMJ Open"},{"key":"2024112006050962000_14.4.442.14","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1016\/j.jpainsymman.2021.07.006","article-title":"Hand-held fans: physical properties and perceptions of patients with COPD","volume":"63","author":"Smith","year":"2022","journal-title":"J Pain Symptom Manage"},{"key":"2024112006050962000_14.4.442.15","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.05.00034805"},{"key":"2024112006050962000_14.4.442.16","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00080312"},{"key":"2024112006050962000_14.4.442.17","doi-asserted-by":"crossref","first-page":"31","DOI":"10.17338\/trainology.6.1_31","article-title":"The reliability of the submaximal version of the yo-yo intermittent recovery test in elite youth soccer","volume":"6","author":"Owen","year":"2017","journal-title":"Journal of Trainology"},{"key":"2024112006050962000_14.4.442.18","doi-asserted-by":"crossref","first-page":"200","DOI":"10.4037\/ajcc1998.7.3.200","article-title":"Validity of the Numeric rating scale as a measure of dyspnea","volume":"7","author":"Gift","year":"1998","journal-title":"Am J Crit Care"},{"key":"2024112006050962000_14.4.442.19","doi-asserted-by":"crossref","DOI":"10.1136\/thx.54.4.374b","article-title":"Repeatability of breathlessness measurements in cancer patients","volume":"54","author":"Wilcock","year":"1999","journal-title":"Thorax"},{"key":"2024112006050962000_14.4.442.20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpainsymman.2013.01.011"},{"key":"2024112006050962000_14.4.442.21","doi-asserted-by":"publisher","DOI":"10.2307\/2346101"},{"key":"2024112006050962000_14.4.442.22","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1152\/jappl.1999.87.6.1997","article-title":"Exercise-induced arterial hypoxemia","volume":"87","author":"Dempsey","year":"1999","journal-title":"J Appl Physiol (1985)"},{"key":"2024112006050962000_14.4.442.23","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.buildenv.2015.08.026","article-title":"Using air movement for comfort during moderate exercise","volume":"94","author":"Zhai","year":"2015","journal-title":"Building and Environment"},{"key":"2024112006050962000_14.4.442.24","doi-asserted-by":"crossref","DOI":"10.1183\/23120541.00211-2021","article-title":"Impact of fan therapy during exercise on breathlessness and recovery time in patients with COPD: a pilot randomised controlled crossover trial","volume":"7","author":"Long","year":"2021","journal-title":"ERJ Open Res"},{"key":"2024112006050962000_14.4.442.25","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1164\/ajrccm\/144.2.419","article-title":"Oral mucosal stimulation modulates intensity of breathlessness induced in normal subjects","volume":"144","author":"Simon","year":"1991","journal-title":"Am Rev Respir Dis"},{"key":"2024112006050962000_14.4.442.26","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/137.6.1285"},{"key":"2024112006050962000_14.4.442.27","doi-asserted-by":"crossref","first-page":"104035","DOI":"10.1016\/j.resp.2023.104035","article-title":"Impact of trigeminal and\/or olfactory nerve stimulation on measures of Inspiratory neural drive: implications for breathlessness","volume":"311","author":"Aucoin","year":"2023","journal-title":"Respir Physiol Neurobiol"},{"key":"2024112006050962000_14.4.442.28","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1080\/23328940.2020.1826840","article-title":"Prolonged facemask use in the heat worsens dyspnea without compromising motor-cognitive performance","volume":"8","author":"Morris","year":"2021","journal-title":"Temperature"},{"key":"2024112006050962000_14.4.442.29","doi-asserted-by":"crossref","unstructured":"Prihartadi AS , Impelliziere Licastro G , Pearson M , et al . Non-medical devices for chronic breathlessness: use, barriers and Facilitators for patients, carers and clinicians - a scoping review. BMJ Support Palliat Care 2021:bmjspcare-2021-002962. doi:10.1136\/bmjspcare-2021-002962","DOI":"10.1136\/bmjspcare-2021-002962"},{"key":"2024112006050962000_14.4.442.30","doi-asserted-by":"publisher","DOI":"10.1177\/0269216315607180"}],"container-title":["BMJ Supportive &amp; Palliative Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/spcare-2023-004309","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,20]],"date-time":"2024-11-20T19:15:49Z","timestamp":1732130149000},"score":1,"resource":{"primary":{"URL":"https:\/\/spcare.bmj.com\/lookup\/doi\/10.1136\/spcare-2023-004309"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,5]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,11,20]]},"published-print":{"date-parts":[[2024,12]]}},"alternative-id":["10.1136\/spcare-2023-004309"],"URL":"https:\/\/doi.org\/10.1136\/spcare-2023-004309","relation":{},"ISSN":["2045-435X","2045-4368"],"issn-type":[{"value":"2045-435X","type":"print"},{"value":"2045-4368","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,5]]}}}