{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T10:05:38Z","timestamp":1766484338391,"version":"3.48.0"},"reference-count":36,"publisher":"BMJ","issue":"6","license":[{"start":{"date-parts":[[2025,2,24]],"date-time":"2025-02-24T00:00:00Z","timestamp":1740355200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Tianjin Municipal Health Commission Special Plan for High Level Talents in Science and Technology Project","award":["TJWJ2024RC016"],"award-info":[{"award-number":["TJWJ2024RC016"]}]},{"name":"Tianjin Health Research Project","award":["TJWJ2022QN061"],"award-info":[{"award-number":["TJWJ2022QN061"]}]},{"name":"Tianjin Medical Talent Project","award":["TJSJMYXYC-D2-059"],"award-info":[{"award-number":["TJSJMYXYC-D2-059"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Stroke Vasc Neurol"],"accepted":{"date-parts":[[2024,12,24]]},"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Dual-energy CT (DECT) provides several novel methods to assess thrombus perviousness. We aimed to evaluate whether the novel thrombus perviousness measured with DECT is associated with improved recanalisation and better functional outcomes in acute ischaemic stroke (AIS) patients with endovascular thrombectomy (EVT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>108 AIS patients with middle cerebral artery occlusion who underwent DECT angiography on admission and received EVT treatment between April 2020 and September 2023 were retrospectively analysed. Thrombus attenuation increase (TAI) was evaluated on routine CT angiography and non-contrast CT, and DECT quantitative parameters of thrombus, including iodine concentration (IC) and normalised IC (NIC) were measured. Multivariable logistic regression analysis was used to evaluate the association of thrombus characteristics with arterial occlusive lesion scale and 90-day modified Rankin Scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>NIC was significantly associated with successful recanalisation (OR 1.372 (95% CI 1.194 to 1.625); p&lt;0.001) and good functional outcome (OR 1.252 (95% CI 1.114 to 1.446); p&lt;0.001). NIC yielded higher performance, with area under curve (AUC) of 0.789 and 0.740, in the prediction of recanalisation and functional outcome than TAI (AUCs=0.635\u2009and 0.592). Compared with low-level NIC thrombus, high-level NIC was associated with 11.4 and 15.4 times higher likelihood of successful recanalisation and good functional outcome. Moreover, NIC was a significant indicator to differentiate large artery atherosclerosis from cardioembolism stroke with high specificity and positive predictive value.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Higher DECT-derived NIC is associated with increased odds of successful recanalisation and good functional outcome for EVT patients, and it yielded higher prediction performance than TAI.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/svn-2024-003661","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T02:35:25Z","timestamp":1740450925000},"page":"670-682","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Thrombus iodine-based perviousness is associated with recanalisation and functional outcomes in endovascular thrombectomy"],"prefix":"10.1136","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1362-7630","authenticated-orcid":false,"given":"Chao","family":"Tian","sequence":"first","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5154-3115","authenticated-orcid":false,"given":"Song","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lejun","family":"Fu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingjing","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Cao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Ren","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huiying","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical Imaging Institute, Tianjin First Central Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sifei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4843-5225","authenticated-orcid":false,"given":"Leilei","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luotong","family":"Wang","sequence":"additional","affiliation":[{"name":"CT Imaging Research Center, GE Healthcare China Co Ltd, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1626-6383","authenticated-orcid":false,"given":"Shuang","family":"Xia","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical Imaging Institute, Tianjin First Central Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Song","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4713-4287","authenticated-orcid":false,"given":"Tong","family":"Han","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nina","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tianjin University, Tianjin Huanhu Hospital, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2025,2,24]]},"reference":[{"key":"2025122302000680000_10.6.670.1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa2314063"},{"key":"2025122302000680000_10.6.670.2","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2214403"},{"key":"2025122302000680000_10.6.670.3","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2213379"},{"key":"2025122302000680000_10.6.670.4","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2118191"},{"key":"2025122302000680000_10.6.670.5","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1161\/STROKEAHA.122.038563","article-title":"Composition, Treatment, and Outcomes by Radiologically Defined Thrombus Characteristics in Acute Ischemic Stroke","volume":"54","author":"Das","year":"2023","journal-title":"Stroke"},{"key":"2025122302000680000_10.6.670.6","doi-asserted-by":"publisher","DOI":"10.5853\/jos.2018.02026"},{"key":"2025122302000680000_10.6.670.7","doi-asserted-by":"crossref","first-page":"7811","DOI":"10.1007\/s00330-022-08762-y","article-title":"Quantitative thrombus characteristics on thin-slice computed tomography improve prediction of thrombus histopathology: results of the MR CLEAN Registry","volume":"32","author":"Hund","year":"2022","journal-title":"Eur Radiol"},{"key":"2025122302000680000_10.6.670.8","doi-asserted-by":"crossref","first-page":"3613","DOI":"10.1161\/STROKEAHA.120.031148","article-title":"Association Between Thrombus Perviousness Assessed on Computed Tomography and Stroke Cause","volume":"51","author":"Kufner","year":"2020","journal-title":"Stroke"},{"key":"2025122302000680000_10.6.670.9","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.118.021873"},{"key":"2025122302000680000_10.6.670.10","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2018.12498"},{"key":"2025122302000680000_10.6.670.11","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.116.013306"},{"key":"2025122302000680000_10.6.670.12","doi-asserted-by":"crossref","first-page":"3633","DOI":"10.1161\/STROKEAHA.120.033124","article-title":"Endovascular Treatment Effect Diminishes With Increasing Thrombus Perviousness: Pooled Data From 7 Trials on Acute Ischemic Stroke","volume":"52","author":"Kappelhof","year":"2021","journal-title":"Stroke"},{"key":"2025122302000680000_10.6.670.13","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.118.024247"},{"key":"2025122302000680000_10.6.670.14","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.117.019509"},{"key":"2025122302000680000_10.6.670.15","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.115.011187"},{"key":"2025122302000680000_10.6.670.16","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2020200038"},{"key":"2025122302000680000_10.6.670.17","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2015142631"},{"key":"2025122302000680000_10.6.670.18","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1148\/radiol.212173","article-title":"Dual-Energy CT Iodine Concentration to Evaluate Postoperative Pancreatic Fistula after Pancreatoduodenectomy","volume":"304","author":"Shi","year":"2022","journal-title":"Radiology"},{"key":"2025122302000680000_10.6.670.19","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1148\/radiol.2021210600","article-title":"Dual-Energy CT Perfusion of Invasive Tumor Front in Non-Small Cell Lung Cancers","volume":"302","author":"Dewaguet","year":"2022","journal-title":"Radiology"},{"key":"2025122302000680000_10.6.670.20","doi-asserted-by":"crossref","first-page":"82","DOI":"10.5853\/jos.2020.03531","article-title":"Dual-Energy CT Angiography Improves Accuracy of Spot Sign for Predicting Hematoma Expansion in Intracerebral Hemorrhage","volume":"23","author":"Peeters","year":"2021","journal-title":"J Stroke"},{"key":"2025122302000680000_10.6.670.21","doi-asserted-by":"crossref","first-page":"110861","DOI":"10.1016\/j.ejrad.2023.110861","article-title":"Dual-energy CT in assessment of thrombus perviousness and its application in predicting outcomes after intravenous thrombolysis in acute ischemic stroke","volume":"164","author":"Dai","year":"2023","journal-title":"Eur J Radiol"},{"key":"2025122302000680000_10.6.670.22","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39335.541782.AD"},{"key":"2025122302000680000_10.6.670.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2012.05.001"},{"key":"2025122302000680000_10.6.670.24","doi-asserted-by":"crossref","first-page":"1866","DOI":"10.1016\/j.acra.2022.12.023","article-title":"The Value of Dual-Energy Computed Tomography Angiography-Derived Parameters in the Evaluation of Clot Composition","volume":"30","author":"Jiang","year":"2023","journal-title":"Acad Radiol"},{"key":"2025122302000680000_10.6.670.25","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.24.1.35"},{"key":"2025122302000680000_10.6.670.26","first-page":"193","article-title":"Effects of thrombolysis for acute stroke in patients with pre-existing disability","volume":"169","author":"Foell","year":"2003","journal-title":"CMAJ"},{"key":"2025122302000680000_10.6.670.27","doi-asserted-by":"publisher","DOI":"10.1136\/jnis-2022-019937"},{"key":"2025122302000680000_10.6.670.28","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1148\/radiol.2019182870","article-title":"Dual-Energy CT: Lower Limits of Iodine Detection and Quantification","volume":"292","author":"Jacobsen","year":"2019","journal-title":"Radiology"},{"key":"2025122302000680000_10.6.670.29","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016799"},{"key":"2025122302000680000_10.6.670.30","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-017-0599-3"},{"key":"2025122302000680000_10.6.670.31","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1177\/1591019917694479","article-title":"Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study","volume":"23","author":"Brinjikji","year":"2017","journal-title":"Interv Neuroradiol"},{"key":"2025122302000680000_10.6.670.32","doi-asserted-by":"publisher","DOI":"10.5853\/jos.2017.00752"},{"key":"2025122302000680000_10.6.670.33","doi-asserted-by":"publisher","DOI":"10.1177\/1747493016641965"},{"key":"2025122302000680000_10.6.670.34","doi-asserted-by":"publisher","DOI":"10.3324\/haematol.2019.219881"},{"key":"2025122302000680000_10.6.670.35","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1159\/000481578","article-title":"Ischemic Stroke: Histological Thrombus Composition and Pre-Interventional CT Attenuation Are Associated with Intervention Time and Rate of Secondary Embolism","volume":"44","author":"Sporns","year":"2017","journal-title":"Cerebrovasc Dis"},{"key":"2025122302000680000_10.6.670.36","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.116.005149","article-title":"Thrombus Migration in the Middle Cerebral Artery: Incidence, Imaging Signs, and Impact on Success of Endovascular Thrombectomy","volume":"6","author":"Kaesmacher","year":"2017","journal-title":"J Am Heart Assoc"}],"container-title":["Stroke and Vascular Neurology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/svn-2024-003661","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T10:00:15Z","timestamp":1766484015000},"score":1,"resource":{"primary":{"URL":"https:\/\/svn.bmj.com\/lookup\/doi\/10.1136\/svn-2024-003661"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,24]]},"references-count":36,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,12,23]]},"published-print":{"date-parts":[[2025,12]]}},"alternative-id":["10.1136\/svn-2024-003661"],"URL":"https:\/\/doi.org\/10.1136\/svn-2024-003661","relation":{},"ISSN":["2059-8688","2059-8696"],"issn-type":[{"type":"print","value":"2059-8688"},{"type":"electronic","value":"2059-8696"}],"subject":[],"published":{"date-parts":[[2025,2,24]]}}}