{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:39:04Z","timestamp":1787017144330,"version":"build-2736575974"},"reference-count":41,"publisher":"BMJ","issue":"6","funder":[{"name":"National Institute for Health and Social Care Research","award":["NIHR award: 302337"],"award-info":[{"award-number":["NIHR award: 302337"]}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Thorax"],"accepted":{"date-parts":[[2025,11,29]]},"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Positive airway pressure (PAP) therapy is the recognised treatment for sleep disordered breathing (SDB), delivered via a tight-fitting face mask (interface). Conventional interfaces do not consider facial geometries, often resulting in poor fit and ineffective therapy. Three-dimensional (3D) printing of customised interfaces may improve comfort and outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To evaluate the clinical impact of customised versus conventional oronasal interfaces in adults with obstrcutive sleep apnoea (OSA). The primary outcome was residual Apnoea Hypopnea Index (AHI) at 6\u2009months; secondary outcomes included interface leak, therapy concordance and patient reported symptoms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A randomised controlled trial with 160 adults na\u00efve to PAP therapy and diagnosed with SDB (AHI \u226515 events\/hour). Randomisation was minimised by age and ethnicity. Structured light facial scans (POP2, Revopoint, China) were used to produce 3D printed moulds (Fuse 30+, Formlabs, Massachusetts, USA) for silicone injected oronasal customised interface cushions.<\/jats:p>\n                    <jats:p>AHI was compared using quantile regression to account for the skewed distribution of the AHI data. Secondary outcomes were compared using logistic, quantile and linear regressions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>160 participants were recruited (intervention: 82, control: 78). Customised interfaces were associated with a 1.5 (events\/hour) increase in AHI (p=0.059), higher interface leak (difference in medians 30.0\u2009L\/min, 95%\u2009CI 7.36 to 40.14, p&lt;0.0001) and lower compliance (difference in compliance 0.78, 95%\u2009CI 0.05 to 1.54, p=0.04) at 6\u2009months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This trial did not demonstrate customised oronasal interfaces were superior to conventional interfaces. Future research should focus on addressing design and manufacturing limitations before any potential advantages can be evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration number<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"isrctn\" xlink:href=\"ISRCTN74082423\">ISRCTN74082423<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/thorax-2025-224135","type":"journal-article","created":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T18:20:35Z","timestamp":1769538035000},"page":"600-606","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Clinical impact of customised positive airway pressure (PAP) therapy interfaces (3DPiPPIn): a single site randomised controlled trial"],"prefix":"10.1136","volume":"81","clinical-trial-number":[{"clinical-trial-number":"isrctn74082423","registry":"10.18810\/isrctn"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2806-380X","authenticated-orcid":false,"given":"Stephanie K","family":"Mansell","sequence":"first","affiliation":[{"name":"University College London, London, UK"},{"name":"Royal Free London NHS Foundation Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2232-5880","authenticated-orcid":false,"given":"Swapna","family":"Mandal","sequence":"additional","affiliation":[{"name":"University College London, London, UK"},{"name":"Royal Free London NHS Foundation Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Gowing","sequence":"additional","affiliation":[{"name":"Royal Free London NHS Foundation Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1336-6450","authenticated-orcid":false,"given":"Deborah","family":"Ridout","sequence":"additional","affiliation":[{"name":"Population Policy and Practice Research and Teaching Department, University College London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2045-1883","authenticated-orcid":false,"given":"Cherry","family":"Kilbride","sequence":"additional","affiliation":[{"name":"Royal Free London NHS Foundation Trust, London, UK"},{"name":"Brunel University London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Olsen","sequence":"additional","affiliation":[{"name":"Independent researcher, Guildford, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8782-4499","authenticated-orcid":false,"given":"Stephen","family":"Hilton","sequence":"additional","affiliation":[{"name":"University College London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9739-3167","authenticated-orcid":false,"given":"Eleanor","family":"Main","sequence":"additional","affiliation":[{"name":"Institute of Child Health, University College London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvia","family":"Schievano","sequence":"additional","affiliation":[{"name":"Institute of Cardiovascular Sciences, University College London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2026,1,27]]},"reference":[{"key":"2026051403202036000_81.6.600.1","doi-asserted-by":"publisher","DOI":"10.1111\/resp.13838"},{"key":"2026051403202036000_81.6.600.2","unstructured":"British Lung Foundation . Obstructive Sleep Apnoea (OSA) toolkit for commissioning and planning local NHS services in the UK. London: British Lung Foundation, 2015."},{"key":"2026051403202036000_81.6.600.3","unstructured":"National Institute for Clinical Excellence . Obstructive sleep apnoea\/hypopnoea syndrome and obesity hypoventilation syndrome in over 16s. NICE guideline [NG202]. NICE; 2021. Available: https:\/\/www.nice.org.uk\/guidance\/ng202"},{"key":"2026051403202036000_81.6.600.4","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1007\/s11325-012-0740-0","article-title":"CPAP interface: satisfaction and side effects","volume":"17","author":"Bachour","year":"2013","journal-title":"Sleep Breath"},{"key":"2026051403202036000_81.6.600.5","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1007\/s11325-018-1640-8","article-title":"Upper airway obstruction induced by non-invasive ventilation using an oronasal interface","volume":"22","author":"Schellhas","year":"2018","journal-title":"Sleep Breath"},{"key":"2026051403202036000_81.6.600.6","doi-asserted-by":"crossref","first-page":"373","DOI":"10.3109\/21678421.2013.776086","article-title":"Prognostic value of efficiently correcting nocturnal desaturations after one month of non-invasive ventilation in amyotrophic lateral sclerosis: a retrospective monocentre observational cohort study","volume":"14","author":"Gonzalez-Bermejo","year":"2013","journal-title":"Amyotroph Lateral Scler Frontotemporal Degener"},{"key":"2026051403202036000_81.6.600.7","doi-asserted-by":"crossref","first-page":"810","DOI":"10.4187\/respcare.04490810","article-title":"The evidence for noninvasive positive-pressure ventilation in the care of patients in acute respiratory failure: a systematic review of the literature","volume":"49","author":"Hess","year":"2004","journal-title":"Respir Care"},{"key":"2026051403202036000_81.6.600.8","doi-asserted-by":"publisher","DOI":"10.1378\/chest.06-2432"},{"key":"2026051403202036000_81.6.600.9","doi-asserted-by":"publisher","DOI":"10.1378\/chest.107.2.375"},{"key":"2026051403202036000_81.6.600.10","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.163.2.9906116"},{"key":"2026051403202036000_81.6.600.11","doi-asserted-by":"crossref","DOI":"10.1183\/13993003.01126-2019","article-title":"External heated humidification during non-invasive ventilation set up: results from a pilot cross-over clinical trial","volume":"55","author":"Mandal","year":"2020","journal-title":"Eur Respir J"},{"key":"2026051403202036000_81.6.600.12","doi-asserted-by":"crossref","DOI":"10.18063\/ijb.v8i2.516","article-title":"Development of a 3D Individualized Mask for Neonatal Non-Invasive Ventilation","volume":"8","author":"Borr\u00e0s-Novell","year":"2022","journal-title":"Int J Bioprint"},{"key":"2026051403202036000_81.6.600.13","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1080\/03091902.2021.1921869","article-title":"Custom-made 3D printed masks for children using non-invasive ventilation: a comparison of 3D scanning technologies and specifications for future clinical service use, guided by patient and professional experience","volume":"45","author":"Willox","year":"2021","journal-title":"J Med Eng Technol"},{"key":"2026051403202036000_81.6.600.14","doi-asserted-by":"crossref","DOI":"10.3390\/jpm12040604","article-title":"Development of Personalized Non-Invasive Ventilation Interfaces for Neonatal and Pediatric Application Using Additive Manufacturing","volume":"12","author":"Bockstedte","year":"2022","journal-title":"J Pers Med"},{"key":"2026051403202036000_81.6.600.15","doi-asserted-by":"crossref","unstructured":"Martelly E , Rana S , Shimada K . Design and Fabrication of Custom-Fit BiPAP and CPAP Masks Using Three-Dimensional Imaging and Three-Dimensional Printing Techniques. J Med Device 2021;15. doi:10.1115\/1.4049981","DOI":"10.1115\/1.4049981"},{"key":"2026051403202036000_81.6.600.16","doi-asserted-by":"crossref","DOI":"10.1183\/23120541.00632-2020","article-title":"Feasibility of three-dimensional facial imaging and printing for producing customised nasal masks for continuous positive airway pressure","volume":"7","author":"Duong","year":"2021","journal-title":"ERJ Open Res"},{"key":"2026051403202036000_81.6.600.17","doi-asserted-by":"crossref","unstructured":"Simpson R , Pascoe JE , Letcher J , et al . Customized, 3d-printed nasal masks for the delivery of noninvasive positive airway pressure in patients with obstructive sleep apnea, preliminary findings. A69 SRN: clinical and physiological insights into the management of SDB; 2020:A2433\u2013A33.","DOI":"10.1164\/ajrccm-conference.2020.201.1_MeetingAbstracts.A2433"},{"key":"2026051403202036000_81.6.600.18","unstructured":"Personalized 3D-printed CPAP masks improve CPAP effectiveness in children with OSA and craniofacial anomalies. Combined Otolaryngology Spring Meetings; 2015."},{"key":"2026051403202036000_81.6.600.19","doi-asserted-by":"crossref","first-page":"115001","DOI":"10.1016\/j.sna.2023.115001","article-title":"Development of a test bench for ventilation masks through 2D and 3D printing processes","volume":"367","author":"Rouchi\u00e9","year":"2024","journal-title":"Sens Actuators A: Phys"},{"key":"2026051403202036000_81.6.600.20","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.05691"},{"key":"2026051403202036000_81.6.600.21","doi-asserted-by":"crossref","first-page":"0310031","DOI":"10.1115\/1.4040187","article-title":"Custom-Fit Three-Dimensional-Printed BiPAP Mask to Improve Compliance in Patients Requiring Long-Term Noninvasive Ventilatory Support","volume":"12","author":"Wu","year":"2018","journal-title":"J Med Device"},{"key":"2026051403202036000_81.6.600.22","doi-asserted-by":"crossref","DOI":"10.18063\/ijb.v9i1.627","article-title":"Feasibility of three-dimensional nasal imaging and printing in producing customized nasal masks for non-invasive ventilation in extremely low birth weight infant: A pilot study","volume":"9","author":"Mart\u00edn-G\u00f3nz\u00e1lez","year":"2023","journal-title":"Int J Bioprint"},{"key":"2026051403202036000_81.6.600.23","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.prosdent.2014.01.030","article-title":"Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure","volume":"113","author":"Cheng","year":"2015","journal-title":"J Prosthet Dent"},{"key":"2026051403202036000_81.6.600.24","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s13246-015-0383-0","article-title":"Development of a method for manufacturing customized nasal mask cushion for CPAP therapy","volume":"38","author":"Hsu","year":"2015","journal-title":"Australas Phys Eng Sci Med"},{"key":"2026051403202036000_81.6.600.25","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/03091902.2025.2532648","article-title":"3DPiPPIN: 3D printing of positive airway pressure (PAP) therapy interfaces: a single site feasibility study","volume":"49","author":"Mansell","year":"2025","journal-title":"J Med Eng Technol"},{"key":"2026051403202036000_81.6.600.26","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2023.101850"},{"key":"2026051403202036000_81.6.600.27","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2024-087234","article-title":"Clinical impact of customised positive airway pressure (PAP) therapy interfaces versus usual care in the treatment of patients with sleep-disordered breathing (3DPiPPIn): a randomised controlled trial protocol","volume":"14","author":"Mansell","year":"2024","journal-title":"BMJ Open"},{"key":"2026051403202036000_81.6.600.28","doi-asserted-by":"publisher","DOI":"10.1097\/01.scs.0000171847.58031.9e"},{"key":"2026051403202036000_81.6.600.29","doi-asserted-by":"publisher","DOI":"10.1097\/00001665-200403000-00027"},{"key":"2026051403202036000_81.6.600.30","doi-asserted-by":"publisher","DOI":"10.1513\/AnnalsATS.202007-864ST"},{"key":"2026051403202036000_81.6.600.31","doi-asserted-by":"publisher","DOI":"10.2307\/1913643"},{"key":"2026051403202036000_81.6.600.32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2008.08.010"},{"key":"2026051403202036000_81.6.600.33","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2019.103208"},{"key":"2026051403202036000_81.6.600.34","doi-asserted-by":"crossref","DOI":"10.1164\/ajrccm.2025.211.Abstracts.A6945","article-title":"3D Printing Positive Pressure Interfaces (3dpippin): Results From a Two-Phase Feasibility Trial","volume":"211","author":"Mansell","year":"2025","journal-title":"Am J Respir Crit Care Med"},{"key":"2026051403202036000_81.6.600.35","doi-asserted-by":"crossref","first-page":"27","DOI":"10.25056\/JCM.2022.6.1.27","article-title":"Application and limitations of facial computed tomography and three-dimensional scanner images for patient-specific three-dimensional printing of a nose mask","volume":"6","author":"Nam","year":"2022","journal-title":"J Cosmet Med"},{"key":"2026051403202036000_81.6.600.36","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.chest.2017.08.017","article-title":"Determinants of Unintentional Leaks During CPAP Treatment in OSA","volume":"153","author":"Lebret","year":"2018","journal-title":"Chest"},{"key":"2026051403202036000_81.6.600.37","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/30.6.711"},{"key":"2026051403202036000_81.6.600.38","doi-asserted-by":"crossref","first-page":"100061","DOI":"10.1016\/j.hsr.2022.100061","article-title":"How many hours per night is enough? A systematic integrative review to identify optimal hours of CPAP therapy use for sleep apnoea","volume":"5","author":"Chaplin","year":"2022","journal-title":"Health Sciences Review"},{"key":"2026051403202036000_81.6.600.39","doi-asserted-by":"crossref","first-page":"9","DOI":"10.5664\/jcsm.11340","article-title":"A novel three-dimensional-printed customized nasal mask for improving CPAP adherence and satisfaction for the treatment of obstructive sleep apnea","volume":"21","author":"Tong","year":"2025","journal-title":"J Clin Sleep Med"},{"key":"2026051403202036000_81.6.600.40","doi-asserted-by":"crossref","first-page":"100602","DOI":"10.1016\/j.xocr.2024.100602","article-title":"THREE-DIMENSIONAL printed continuous positive airway pressure masks in children with maxillofacial deformities with obstructive sleep apnea","volume":"31","author":"Tanoto","year":"2024","journal-title":"Otolaryngology Case Reports"},{"key":"2026051403202036000_81.6.600.41","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04492"}],"container-title":["Thorax"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/thorax-2025-224135","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T10:21:27Z","timestamp":1778754087000},"score":1,"resource":{"primary":{"URL":"https:\/\/thorax.bmj.com\/lookup\/doi\/10.1136\/thorax-2025-224135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,27]]},"references-count":41,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,5,14]]},"published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1136\/thorax-2025-224135"],"URL":"https:\/\/doi.org\/10.1136\/thorax-2025-224135","relation":{},"ISSN":["0040-6376","1468-3296"],"issn-type":[{"value":"0040-6376","type":"print"},{"value":"1468-3296","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,27]]}}}