{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T03:39:01Z","timestamp":1790825941323,"version":"4.1.0"},"reference-count":23,"publisher":"BMJ","issue":"2","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Thorax"],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Transcutaneous carbon dioxide (TcCO<jats:sub>2<\/jats:sub>) monitoring is a non-invasive alternative to arterial blood sampling. The aim of this review was to determine the accuracy and precision of TcCO<jats:sub>2<\/jats:sub> measurements.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Medline and EMBASE (2000\u20132016) were searched for studies that reported on a measurement of PaCO<jats:sub>2<\/jats:sub> that coincided with a measurement of TcCO<jats:sub>2<\/jats:sub>. Study selection and quality assessment (using the revised Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2)) were performed independently. The Grading Quality of Evidence and Strength of Recommendation approach was used to summarise the strength of the body of evidence. Pooled estimates of the mean bias between TcCO<jats:sub>2<\/jats:sub> and PaCO<jats:sub>2<\/jats:sub> and limits of agreement with outer 95% CIs (termed population limits of agreement) were calculated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean bias was \u22120.1\u2009mm Hg and the population limits of agreement were \u221215 to 15\u2009mm Hg for 7021 paired measurements taken from 2817 participants in 73 studies, which was outside of the clinically acceptable range (7.5\u2009mm Hg). The lowest PaCO<jats:sub>2<\/jats:sub> reported in the studies was 18\u2009mm Hg and the highest was 103\u2009mm Hg. The major sources of inconsistency were sensor location and temperature. The population limits of agreement were within the clinically acceptable range across 3974 paired measurements from 1786 participants in 44 studies that applied the sensor to the earlobe using the TOSCA and Sentec devices (\u22126 to 6\u2009mm Hg).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>There are substantial differences between TcCO<jats:sub>2<\/jats:sub> and PaCO<jats:sub>2<\/jats:sub> depending on the context in which this technology is used. TcCO<jats:sub>2<\/jats:sub> sensors should preferentially be applied to the earlobe and users should consider setting the temperature of the sensor higher than 42\u00b0C when monitoring at other sites.<\/jats:p><\/jats:sec><jats:sec><jats:title>Systematic review registration number<\/jats:title><jats:p>PROSPERO; CRD42017057450.<\/jats:p><\/jats:sec>","DOI":"10.1136\/thoraxjnl-2017-211466","type":"journal-article","created":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T16:16:37Z","timestamp":1536768997000},"page":"157-163","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":74,"title":["Accuracy and precision of transcutaneous carbon dioxide monitoring: a systematic review and meta-analysis"],"prefix":"10.1136","volume":"74","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9583-8636","authenticated-orcid":false,"given":"Aaron","family":"Conway","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Tipton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Hong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary","family":"Conway","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathleen","family":"Soalheira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanna","family":"Sutherland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9148-196X","authenticated-orcid":false,"given":"James","family":"Fingleton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,9,12]]},"reference":[{"key":"2020050723471170000_74.2.157.1","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1513\/AnnalsATS.201311-387FR","article-title":"Techniques for the measurement and monitoring of carbon dioxide in the blood","volume":"11","author":"Huttmann","year":"2014","journal-title":"Ann Am Thorac Soc"},{"key":"2020050723471170000_74.2.157.2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.317.7167.1213"},{"key":"2020050723471170000_74.2.157.3","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/s13643-015-0074-7","article-title":"Improving search efficiency for systematic reviews of diagnostic test accuracy: an exploratory study to assess the viability of limiting to MEDLINE, EMBASE and reference checking","volume":"4","author":"Preston","year":"2015","journal-title":"Syst Rev"},{"key":"2020050723471170000_74.2.157.4","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/2046-4053-1-9","article-title":"Should methodological filters for diagnostic test accuracy studies be used in systematic reviews of psychometric instruments? A case study involving screening for postnatal depression","volume":"1","author":"Mann","year":"2012","journal-title":"Syst Rev"},{"key":"2020050723471170000_74.2.157.5","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aem214"},{"key":"2020050723471170000_74.2.157.6","doi-asserted-by":"publisher","DOI":"10.1059\/0003-4819-155-8-201110180-00009"},{"key":"2020050723471170000_74.2.157.7","doi-asserted-by":"crossref","unstructured":"Glasziou P , Irwig L , Bain C , et al . Systematic Reviews in Health Care: A Practical Guide: Taylor & Francis, 2002.","DOI":"10.1017\/CBO9780511543500"},{"key":"2020050723471170000_74.2.157.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2005.03.006"},{"key":"2020050723471170000_74.2.157.9","doi-asserted-by":"crossref","first-page":"768","DOI":"10.7326\/M15-1150","article-title":"Accuracy of peripheral thermometers for estimating temperature: a systematic review and meta-analysis","volume":"163","author":"Niven","year":"2015","journal-title":"Ann Intern Med"},{"key":"2020050723471170000_74.2.157.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2005.01.016"},{"key":"2020050723471170000_74.2.157.11","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39500.677199.AE"},{"key":"2020050723471170000_74.2.157.12","doi-asserted-by":"crossref","first-page":"3621","DOI":"10.1002\/sim.7352","article-title":"A framework for the meta-analysis of Bland-Altman studies based on a limits of agreement approach","volume":"36","author":"Tipton","year":"2017","journal-title":"Stat Med"},{"key":"2020050723471170000_74.2.157.13","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s40865-016-0026-5","article-title":"Handling complex meta-analytic data structures using robust variance estimates: a tutorial in R","volume":"2","author":"Tanner-Smith","year":"2016","journal-title":"J Dev Life Course Criminol"},{"key":"2020050723471170000_74.2.157.14","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1002\/jrsm.17","article-title":"Robust variance estimation in meta-regression with dependent effect size estimates","volume":"1","author":"Hedges","year":"2010","journal-title":"Res Synth Methods"},{"key":"2020050723471170000_74.2.157.15","doi-asserted-by":"publisher","DOI":"10.1037\/met0000011"},{"key":"2020050723471170000_74.2.157.16","doi-asserted-by":"publisher","DOI":"10.1016\/0197-2456(86)90046-2"},{"key":"2020050723471170000_74.2.157.17","unstructured":"Team RC Core Team R. R: a language and environment for statistical computing. Vienna, Austria: \u00a0R Foundation for statistical computing, 2017. http:\/\/www.R-project.org\/."},{"key":"2020050723471170000_74.2.157.18","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.02011"},{"key":"2020050723471170000_74.2.157.19","doi-asserted-by":"publisher","DOI":"10.1016\/j.resp.2006.07.002"},{"key":"2020050723471170000_74.2.157.20","doi-asserted-by":"publisher","DOI":"10.1111\/resp.12225"},{"key":"2020050723471170000_74.2.157.21","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aew094"},{"key":"2020050723471170000_74.2.157.22","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04212"},{"key":"2020050723471170000_74.2.157.23","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1213\/ANE.0000000000001462","article-title":"Transcutaneous pco2 monitoring in newborn infants during general anesthesia is technically feasible","volume":"123","author":"Karlsson","year":"2016","journal-title":"Anesth Analg"}],"container-title":["Thorax"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/thoraxjnl-2017-211466","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T06:05:57Z","timestamp":1601100357000},"score":1,"resource":{"primary":{"URL":"https:\/\/thorax.bmj.com\/lookup\/doi\/10.1136\/thoraxjnl-2017-211466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,12]]},"references-count":23,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2019,1,15]]},"published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.1136\/thoraxjnl-2017-211466"],"URL":"https:\/\/doi.org\/10.1136\/thoraxjnl-2017-211466","relation":{},"ISSN":["0040-6376","1468-3296"],"issn-type":[{"value":"0040-6376","type":"print"},{"value":"1468-3296","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,12]]}}}