{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T11:31:20Z","timestamp":1771327880433,"version":"3.50.1"},"reference-count":7,"publisher":"BMJ","issue":"4","license":[{"start":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T00:00:00Z","timestamp":1633564800000},"content-version":"unspecified","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["World Jnl Ped Surgery"],"accepted":{"date-parts":[[2021,9,21]]},"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                  <jats:title>Introduction<\/jats:title>\n                  <jats:p>Suction rectal biopsy (SRB) is a key diagnostic tool in Hirschsprung\u2019s disease. The original Noblett device has been superseded by modern alternatives including the Rbi2 rectal biopsy gun. We describe a comparison of biopsy results from the Noblett device and the Rbi2 gun and an investigation into significant post-biopsy bleeding episodes with the latter.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>A retrospective review of SRB episodes between 2006 and 2014 was undertaken to audit biopsy success rates. Significant post-procedure bleeding after SRB with the Rbi2 gun prompted further investigations.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Biopsies taken with the Noblett gun were more likely to be inadequate (Noblett 82\/197 (40%) vs Rbi2 77\/438 (18%)). After biopsy with the Rbi2 gun, 2 infants suffered from significant bleeding requiring resuscitation, blood product support and multiple theater episodes. As there were no reported cases of bleeding with the Rbi2 gun, a report was made to the Medicines &amp; Healthcare products Regulatory Agency who identified incorrect biopsy technique as a potential contributing factor. A questionnaire of trainees and consultants found unexpected individual variation in SRB technique, with some users applying excessive suction.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Significant bleeding occurred after SRB with the Rbi2 gun, excessive suction was thought to be the cause.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/wjps-2021-000319","type":"journal-article","created":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T13:15:19Z","timestamp":1633612519000},"page":"e000319","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Bleeding after suction rectal biopsy with Rbi2: identification of the root cause through a multi-staged approach"],"prefix":"10.1136","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5470-1457","authenticated-orcid":false,"given":"Harriet J","family":"Corbett","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramanand","family":"Jeeneea","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iain","family":"Hennessey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"239","published-online":{"date-parts":[[2021,10,7]]},"reference":[{"key":"2025081809533266000_4.4.e000319.1","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s12519-015-0068-5","article-title":"Rectal biopsy for Hirschsprung's disease: a review of techniques, pathology, and complications","volume":"12","author":"Muise","year":"2016","journal-title":"World J Pediatr"},{"key":"2025081809533266000_4.4.e000319.2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3468(69)90606-X"},{"key":"2025081809533266000_4.4.e000319.3","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1007\/s00383-016-3907-0","article-title":"Current practice patterns of rectal suction biopsy in the diagnostic work-up of Hirschsprung's disease: results from an international survey","volume":"32","author":"Friedmacher","year":"2016","journal-title":"Pediatr Surg Int"},{"key":"2025081809533266000_4.4.e000319.4","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1007\/s00383-015-3742-8","article-title":"Rectal suction biopsy for the diagnosis of Hirschsprung's disease: a systematic review of diagnostic accuracy and complications","volume":"31","author":"Friedmacher","year":"2015","journal-title":"Pediatr Surg Int"},{"key":"2025081809533266000_4.4.e000319.5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2008.10.093"},{"key":"2025081809533266000_4.4.e000319.6","unstructured":"Cox M , Marei M , Munro F . Review of adequacy of suction rectal biopsies over two years. Edingburgh, UK: Scottish Surgical Paediatric Society, 2016."},{"key":"2025081809533266000_4.4.e000319.7","unstructured":"Good medical practice . Manchester, General Medical Council, 2013. Available: www.gmc-uk.org\/static\/documents\/content\/GMP_.pdf [Accessed 29 Apr 2014]."}],"container-title":["World Journal of Pediatric Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/wjps-2021-000319","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T16:53:37Z","timestamp":1755536017000},"score":1,"resource":{"primary":{"URL":"https:\/\/wjps.bmj.com\/lookup\/doi\/10.1136\/wjps-2021-000319"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":7,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,10,7]]},"published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.1136\/wjps-2021-000319"],"URL":"https:\/\/doi.org\/10.1136\/wjps-2021-000319","relation":{},"ISSN":["2516-5410"],"issn-type":[{"value":"2516-5410","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}