{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T03:04:14Z","timestamp":1793675054728,"version":"4.5.1"},"reference-count":26,"publisher":"BMJ","issue":"3","license":[{"start":{"date-parts":[[2024,10,14]],"date-time":"2024-10-14T00:00:00Z","timestamp":1728864000000},"content-version":"unspecified","delay-in-days":13,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100017577","name":"Basic Public Welfare Research Program of Zhejiang Province","doi-asserted-by":"publisher","award":["LY23H020007"],"award-info":[{"award-number":["LY23H020007"]}],"id":[{"id":"10.13039\/501100017577","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["World Jnl Ped Surgery"],"accepted":{"date-parts":[[2024,8,5]]},"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To develop a model using patient-specific computational fluid dynamics (CFD) to predict the required anastomotic size for total anomalous pulmonary venous connection (TAPVC) surgery and to forecast surgical outcomes.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Based on clinical data from patients, a CFD model was used to simulate the anastomosis between pulmonary venous confluence and the left atrium. Blood flow velocity, wall shear stress, power loss, and pressure were calculated using numerical algorithms within the model. Various sizes of anastomosis were applied during the simulation. The energy dissipation at the anastomosis was computed from the results and compared with real-world data.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>As the simulated anastomotic size increased, blood flow velocity, pulmonary venous pressure, and energy loss decreased. However, when the anastomotic size exceeded 18\u2009mm, the efficiency of energy conversion no longer improved. The realistic and simulated velocities matched well for anastomosis sizes ranging from 15 to 20\u2009mm.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>The model can assist surgeons in preoperative planning for determining the anastomotic size in TAPVC surgical treatment.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1136\/wjps-2023-000741","type":"journal-article","created":{"date-parts":[[2024,10,14]],"date-time":"2024-10-14T22:40:13Z","timestamp":1728945613000},"page":"e000741","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":2,"title":["Numerical modeling assisting in surgical treatment of total anomalous pulmonary venous connection in children"],"prefix":"10.1136","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7116-0322","authenticated-orcid":false,"given":"Jie","family":"Jin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyun","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiawei","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0078-4699","authenticated-orcid":false,"given":"Jing","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangming","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2024,10,14]]},"reference":[{"key":"2025081810073214000_7.3.e000741.1","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1053\/j.pcsu.2017.11.010","article-title":"Surgical Approaches to Total Anomalous Pulmonary Venous Connection","volume":"21","author":"Vanderlaan","year":"2018","journal-title":"Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu"},{"key":"2025081810073214000_7.3.e000741.2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.07.005"},{"key":"2025081810073214000_7.3.e000741.3","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(03)00180-5"},{"key":"2025081810073214000_7.3.e000741.4","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(99)00104-9"},{"key":"2025081810073214000_7.3.e000741.5","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1161\/01.CIR.46.2.347","article-title":"Total Anomalous Pulmonary Venous Drainage in Infants","volume":"46","author":"Behrendt","year":"1972","journal-title":"Circulation"},{"key":"2025081810073214000_7.3.e000741.6","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)64970-3"},{"key":"2025081810073214000_7.3.e000741.7","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2010.517200"},{"key":"2025081810073214000_7.3.e000741.8","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1007\/s13239-015-0244-8","article-title":"A Patient-Specific Computational Fluid Dynamic Model for Hemodynamic Analysis of Left Ventricle Diastolic Dysfunctions","volume":"6","author":"Nguyen","year":"2015","journal-title":"Cardiovasc Eng Technol"},{"key":"2025081810073214000_7.3.e000741.9","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1007\/s10237-017-0962-y","article-title":"A numerical study of the hemodynamic effect of the aortic valve on coronary flow","volume":"17","author":"Wald","year":"2018","journal-title":"Biomech Model Mechanobiol"},{"key":"2025081810073214000_7.3.e000741.10","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/s12265-017-9781-x","article-title":"Patient-Specific Modeling of Hemodynamics: Supporting Surgical Planning in a Fontan Circulation Correction","volume":"11","author":"van Bakel","year":"2018","journal-title":"J Cardiovasc Transl Res"},{"key":"2025081810073214000_7.3.e000741.11","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-010-9978-5"},{"key":"2025081810073214000_7.3.e000741.12","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s13239-021-00558-3","article-title":"Computational Modeling of Right Ventricular Motion and Intracardiac Flow in Repaired Tetralogy of Fallot","volume":"13","author":"Loke","year":"2022","journal-title":"Cardiovasc Eng Technol"},{"key":"2025081810073214000_7.3.e000741.13","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2020.00206","article-title":"Numerical Simulation of Hemodynamics in Two Models for Total Anomalous Pulmonary Venous Connection Surgery","volume":"11","author":"Cheng","year":"2020","journal-title":"Front Physiol"},{"key":"2025081810073214000_7.3.e000741.14","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2351032106"},{"key":"2025081810073214000_7.3.e000741.15","doi-asserted-by":"crossref","unstructured":"Lantz J , Henriksson L , Persson A , et al . Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography. J Biomech Eng 2016;138. doi:10.1115\/1.4034652","DOI":"10.1115\/1.4034652"},{"key":"2025081810073214000_7.3.e000741.16","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.2508"},{"key":"2025081810073214000_7.3.e000741.17","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-018-02153-5"},{"key":"2025081810073214000_7.3.e000741.18","doi-asserted-by":"publisher","DOI":"10.1177\/2150135115589999"},{"key":"2025081810073214000_7.3.e000741.19","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S1350-4533(01)00035-2","article-title":"Effects of pulmonary afterload on the hemodynamics after the hemi-Fontan procedure","volume":"23","author":"Guadagni","year":"2001","journal-title":"Medical Engineering & Physics"},{"key":"2025081810073214000_7.3.e000741.20","doi-asserted-by":"publisher","DOI":"10.1115\/1.1632523"},{"key":"2025081810073214000_7.3.e000741.21","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1007\/s13239-022-00613-7","article-title":"Fluid-Structure Interaction Model for Predicting Surgical Result of Total Anomalous Pulmonary Venous Connection and Estimating Pulmonary Venous Properties","volume":"13","author":"Jin","year":"2022","journal-title":"Cardiovasc Eng Technol"},{"key":"2025081810073214000_7.3.e000741.22","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1177\/112972981001100111","article-title":"Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis","volume":"11","author":"Van Canneyt","year":"2010","journal-title":"J Vasc Access"},{"key":"2025081810073214000_7.3.e000741.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2006.10.018"},{"key":"2025081810073214000_7.3.e000741.24","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.116.023889"},{"key":"2025081810073214000_7.3.e000741.25","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.635441"},{"key":"2025081810073214000_7.3.e000741.26","article-title":"The Role of Elevated Wall Shear Stress in Progression of Pulmonary Vein Stenosis: Evidence from Two Case Studies","volume":"8","author":"Hammer","year":"2021","journal-title":"Children (Basel)"}],"container-title":["World Journal of Pediatric Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/wjps-2023-000741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T17:07:38Z","timestamp":1755536858000},"score":1,"resource":{"primary":{"URL":"https:\/\/wjps.bmj.com\/lookup\/doi\/10.1136\/wjps-2023-000741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":26,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,10,14]]},"published-print":{"date-parts":[[2024,10]]}},"alternative-id":["10.1136\/wjps-2023-000741"],"URL":"https:\/\/doi.org\/10.1136\/wjps-2023-000741","relation":{},"ISSN":["2516-5410"],"issn-type":[{"value":"2516-5410","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10]]}}}