{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T00:59:13Z","timestamp":1794617953886,"version":"4.9.1"},"reference-count":27,"publisher":"BMJ","issue":"7","content-domain":{"domain":["bmj.com"],"crossmark-restriction":true},"short-container-title":["Gut"],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Although lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off necrosis (WON), their advantage over plastic stents is unclear. We compared efficacy of LAMS and plastic stents for WON drainage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Patients with WON were randomised to endoscopic ultrasound-guided drainage using LAMS or plastic stents. Primary outcome was comparing total number of procedures to achieve treatment success defined as symptom relief in conjunction with WON resolution on CT at 6 months. Secondary outcomes were treatment success, procedure duration, clinical\/stent-related adverse events, readmissions, length of hospital stay (LOS) and costs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>60 patients underwent LAMS (n=31) or plastic stent (n=29) placement. There was no significant difference in total number of procedures performed (median 2 (range 2\u20137) LAMS vs 3 (range 2\u20137) plastic, p=0.192), treatment success, clinical adverse events, readmissions, LOS and overall treatment costs between cohorts. Although procedure duration was shorter (15 vs 40 min, p&lt;0.001), stent-related adverse events (32.3% vs 6.9%, p=0.01) and procedure costs (US$12\u2009155 vs US$6609, p&lt;0.001) were higher with LAMS. Significant stent-related adverse events were observed \u22653 weeks postintervention in LAMS cohort. Interim audit resulted in protocol amendment where CT scan was obtained at 3\u2009weeks postintervention followed by LAMS removal if WON had resolved. After protocol amendment, there was no significant difference in adverse events between cohorts.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Except for procedure duration, there was no significant difference in treatment outcomes between LAMS and plastic stents. To minimise adverse events with LAMS, patients should undergo follow-up imaging and stent removal at 3 weeks if WON has resolved.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration number<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"NCT02685865\" ext-link-type=\"clintrialgov\">NCT02685865<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1136\/gutjnl-2017-315335","type":"journal-article","created":{"date-parts":[[2019,8,8]],"date-time":"2019-08-08T11:54:06Z","timestamp":1565265246000},"page":"1200-1209","update-policy":"https:\/\/doi.org\/10.1136\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":320,"title":["Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial"],"prefix":"10.1136","volume":"68","clinical-trial-number":[{"clinical-trial-number":"nct02685865","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Ji Young","family":"Bang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Udayakumar","family":"Navaneethan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad K","family":"Hasan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryce","family":"Sutton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Hawes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shyam","family":"Varadarajulu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"239","published-online":{"date-parts":[[2018,6,1]]},"reference":[{"key":"2020050721350626000_68.7.1200.1","doi-asserted-by":"publisher","DOI":"10.1053\/j.gastro.2013.05.046"},{"key":"2020050721350626000_68.7.1200.2","doi-asserted-by":"crossref","first-page":"2877","DOI":"10.1007\/s00464-014-3541-7","article-title":"Relationship between stent characteristics and treatment outcomes in endoscopic transmural drainage of uncomplicated pancreatic pseudocysts","volume":"28","author":"Bang","year":"2014","journal-title":"Surg Endosc"},{"key":"2020050721350626000_68.7.1200.3","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2002.125106"},{"key":"2020050721350626000_68.7.1200.4","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1007\/s11605-011-1621-8","article-title":"Endoscopic transmural drainage of peripancreatic fluid collections: outcomes and predictors of treatment success in 211 consecutive patients","volume":"15","author":"Varadarajulu","year":"2011","journal-title":"J Gastrointest Surg"},{"key":"2020050721350626000_68.7.1200.5","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1007\/s11605-011-1759-4","article-title":"Dual modality drainage for symptomatic walled-off pancreatic necrosis reduces length of hospitalization, radiological procedures, and number of endoscopies compared to standard percutaneous drainage","volume":"16","author":"Gluck","year":"2012","journal-title":"J Gastrointest Surg"},{"key":"2020050721350626000_68.7.1200.6","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.gie.2011.03.1122","article-title":"Multiple transluminal gateway technique for EUS-guided drainage of symptomatic walled-off pancreatic necrosis","volume":"74","author":"Varadarajulu","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"2020050721350626000_68.7.1200.7","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2010.10.053"},{"key":"2020050721350626000_68.7.1200.8","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.gie.2012.04.457","article-title":"Prospective evaluation of the use of fully covered self-expanding metal stents for EUS-guided transmural drainage of pancreatic pseudocysts","volume":"76","author":"Penn","year":"2012","journal-title":"Gastrointest Endosc"},{"key":"2020050721350626000_68.7.1200.9","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-012-2591-y"},{"key":"2020050721350626000_68.7.1200.10","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.10.020"},{"key":"2020050721350626000_68.7.1200.11","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1391301"},{"key":"2020050721350626000_68.7.1200.12","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/den.12681","article-title":"Lumen-apposing metal stents for drainage of pancreatic fluid collections: When and for whom?","volume":"29","author":"Bang","year":"2017","journal-title":"Dig Endosc"},{"key":"2020050721350626000_68.7.1200.13","doi-asserted-by":"publisher","DOI":"10.1136\/gutjnl-2012-302779"},{"key":"2020050721350626000_68.7.1200.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2006.06.083"},{"key":"2020050721350626000_68.7.1200.15","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-6296(01)00086-8"},{"key":"2020050721350626000_68.7.1200.16","doi-asserted-by":"publisher","DOI":"10.2307\/2346405"},{"key":"2020050721350626000_68.7.1200.17","doi-asserted-by":"publisher","DOI":"10.1093\/biostatistics\/kxh020"},{"key":"2020050721350626000_68.7.1200.18","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2010.12.036"},{"key":"2020050721350626000_68.7.1200.19","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1002\/bjs.9664","article-title":"Outcomes after implementing a tailored endoscopic step-up approach to walled-off necrosis in acute pancreatitis","volume":"101","author":"Bang","year":"2014","journal-title":"Br J Surg"},{"key":"2020050721350626000_68.7.1200.20","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1055\/s-0029-1244021","article-title":"Temporary cystogastrostomy with self-expanding metallic stents for pancreatic necrosis","volume":"42","author":"Belle","year":"2010","journal-title":"Endoscopy"},{"key":"2020050721350626000_68.7.1200.21","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1016\/j.gie.2016.08.014","article-title":"Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success","volume":"85","author":"Siddiqui","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"2020050721350626000_68.7.1200.22","doi-asserted-by":"crossref","unstructured":"Lang GD , Fritz C , Bhat T , et al . EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates. Gastrointest Endosc 2018;87. Epub ahead of print.doi:10.1016\/j.gie.2017.06.029","DOI":"10.1016\/j.gie.2017.06.029"},{"key":"2020050721350626000_68.7.1200.23","doi-asserted-by":"crossref","unstructured":"Bang JY , Hasan M , Navaneethan U , et al . Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usual. Gut 2017;66. Epub ahead of print.doi:10.1136\/gutjnl-2016-312812","DOI":"10.1136\/gutjnl-2016-312812"},{"key":"2020050721350626000_68.7.1200.24","doi-asserted-by":"crossref","unstructured":"Bang JY , Wilcox CM , Navaneethan U , et al . Impact of Disconnected Pancreatic Duct Syndrome on the Endoscopic Management of Pancreatic Fluid Collections. Ann Surg 2016:1. Epub ahead of print.doi:10.1097\/SLA.0000000000002082","DOI":"10.1097\/SLA.0000000000002082"},{"key":"2020050721350626000_68.7.1200.25","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1111\/den.12794","article-title":"Technical review of endoscopic ultrasonography-guided gastroenterostomy in 2017","volume":"29","author":"Itoi","year":"2017","journal-title":"Dig Endosc"},{"key":"2020050721350626000_68.7.1200.26","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.gie.2017.02.027","article-title":"EUS-guided gallbladder drainage in patients with acute\u00a0cholecystitis and high surgical risk using an electrocautery-enhanced lumen-apposing metal stent device","volume":"86","author":"Dollhopf","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"2020050721350626000_68.7.1200.27","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.gie.2016.08.028","article-title":"Use of a lumen-apposing metal stent to treat GI strictures (with\u00a0videos)","volume":"85","author":"Irani","year":"2017","journal-title":"Gastrointest Endosc"}],"container-title":["Gut"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1136\/gutjnl-2017-315335","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,25]],"date-time":"2020-09-25T13:03:49Z","timestamp":1601039029000},"score":1,"resource":{"primary":{"URL":"https:\/\/gut.bmj.com\/lookup\/doi\/10.1136\/gutjnl-2017-315335"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,1]]},"references-count":27,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2019,6,7]]},"published-print":{"date-parts":[[2019,7]]}},"alternative-id":["10.1136\/gutjnl-2017-315335"],"URL":"https:\/\/doi.org\/10.1136\/gutjnl-2017-315335","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.733367661.793565112","asserted-by":"object"}]},"ISSN":["0017-5749","1468-3288"],"issn-type":[{"value":"0017-5749","type":"print"},{"value":"1468-3288","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,1]]}}}