{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T07:36:12Z","timestamp":1778916972086,"version":"3.51.4"},"reference-count":8,"publisher":"World Scientific Pub Co Pte Lt","issue":"02","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J CIRCUIT SYST COMP"],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:p> This paper presents an investigation on mitigation of current harmonics, using Cascaded H-bridge Multilevel Converter (CHB-MLC)-based Shunt Active Power Filter (SAPF). Development and analysis of SAPF for harmonic compensation in distribution network for power quality improvement has been discussed. In the proposed work, transformer-less CHB MLC is used which reduces weight and cost of the system. Moreover, a novel controller based on average power method is adopted for generation of compensation active filter current. In order to generate switching signals, multi-carrier Alternate Phase Opposition Disposition (APOD) \u2014 Pulse Width Modulation (PWM) schemes are used. The proposed CHB-MLC SAPF reduces the source current THD below 5%. The results are simulated in MATLAB\/Simulink and demonstrate the effective mitigation of current harmonics with APOD-PWM schemes. Opal-RT OP4500 real-time digital simulator is used to validate the proposed scheme under different steady state and transient conditions. <\/jats:p>","DOI":"10.1142\/s021812661950035x","type":"journal-article","created":{"date-parts":[[2018,5,8]],"date-time":"2018-05-08T02:32:46Z","timestamp":1525746766000},"page":"1950035","source":"Crossref","is-referenced-by-count":18,"title":["Five-Level Cascaded H-Bridge MLC-Based Shunt Active Power Filter for Active Harmonics Mitigation in Distributed Network"],"prefix":"10.1142","volume":"28","author":[{"given":"Jitendra","family":"Tandekar","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, M.P. India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit","family":"Ojha","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, M.P. India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shailendra","family":"Jain","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, M.P. India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"219","published-online":{"date-parts":[[2018,11,12]]},"reference":[{"key":"S021812661950035XBIB001","doi-asserted-by":"publisher","DOI":"10.1109\/41.793345"},{"key":"S021812661950035XBIB003","doi-asserted-by":"publisher","DOI":"10.6113\/JPE.2016.16.1.142"},{"key":"S021812661950035XBIB005","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2014.10.034"},{"key":"S021812661950035XBIB007","first-page":"342","volume":"9","author":"Ojha A.","year":"2017","journal-title":"Int. J. Electr. Eng. Inf."},{"key":"S021812661950035XBIB011","doi-asserted-by":"publisher","DOI":"10.1109\/59.651624"},{"key":"S021812661950035XBIB012","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2003.820191"},{"key":"S021812661950035XBIB013","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.1986.4504743"},{"key":"S021812661950035XBIB014","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2218558"}],"container-title":["Journal of Circuits, Systems and Computers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.worldscientific.com\/doi\/pdf\/10.1142\/S021812661950035X","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,6]],"date-time":"2019-08-06T15:29:04Z","timestamp":1565105344000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.worldscientific.com\/doi\/abs\/10.1142\/S021812661950035X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,12]]},"references-count":8,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2018,11,12]]},"published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.1142\/S021812661950035X"],"URL":"https:\/\/doi.org\/10.1142\/s021812661950035x","relation":{},"ISSN":["0218-1266","1793-6454"],"issn-type":[{"value":"0218-1266","type":"print"},{"value":"1793-6454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,12]]}}}