{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T18:10:38Z","timestamp":1648663838726},"reference-count":31,"publisher":"World Scientific Pub Co Pte Lt","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int. J. Human. Robot."],"published-print":{"date-parts":[[2008,3]]},"abstract":"<jats:p>Starting from a biomechanical study of the shoulder complex, the relevance of a serial nine d.o.f. kinematic model of the human arm, including a clavicle-like link, was analyzed. It is shown that this partial biomimetic joint model of the upper limb is able to mimic the ability of the natural arm to practically eliminate internal and bound singularities over a large frontal zone, so as to maintain its elbow laterally to the body. In this sense, it appears to be an advanced solution for increasing the dexterity of humanoid robot upper limbs, thus replacing classical seven d.o.f. anthropomorphic arms where a device mimicking the shoulder girdle mechanism is absent.<\/jats:p>","DOI":"10.1142\/s0219843608001327","type":"journal-article","created":{"date-parts":[[2008,4,9]],"date-time":"2008-04-09T09:44:44Z","timestamp":1207734284000},"page":"87-118","source":"Crossref","is-referenced-by-count":5,"title":["A KINEMATIC MODEL OF THE UPPER LIMB WITH A CLAVICLE-LIKE LINK FOR HUMANOID ROBOTS"],"prefix":"10.1142","volume":"05","author":[{"given":"BERTRAND","family":"TONDU","sequence":"first","affiliation":[{"name":"LATTIS\/INSA, Universit\u00e9 de Toulouse, Campus Universitaire de Rangueil, 31077 Toulouse, France"}]}],"member":"219","published-online":{"date-parts":[[2011,11,20]]},"reference":[{"key":"rf1","volume-title":"Robot Evolution. The Development of Anthrobotics","author":"Rosheim M. E.","year":"1994"},{"key":"rf5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1955.tb32112.x"},{"key":"rf6","first-page":"49","author":"Dempster W. T.","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"rf7","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1115\/1.3168351","volume":"111","author":"Engin A. E.","journal-title":"J. Biomech. Eng."},{"key":"rf8","doi-asserted-by":"publisher","DOI":"10.1115\/1.3118775"},{"key":"rf9","volume-title":"Machines & Mechanisms","author":"Myszka D. H.","year":"2002"},{"key":"rf10","volume-title":"Physiology of the Joints, T.1, Upper Limb","author":"Kapandji I. A.","year":"1982"},{"key":"rf11","unstructured":"C. J. D.\u00a0Valle, Basic Biomechanics of the Musculoskeletal System, 3rd edn., eds. M.\u00a0Nordin and V. H.\u00a0Frankel (Lippincott Williams & Wilkins, 2001)\u00a0pp. 318\u2013339."},{"key":"rf12","volume-title":"Kinesiology of the Human Body under Normal and Pathological Conditions","author":"Steindler A.","year":"1955"},{"key":"rf13","volume-title":"Shoulder Pain","author":"Caillet R.","year":"1991"},{"key":"rf14","volume-title":"Kinematics of Human Motion","author":"Zatsiorsky V. M.","year":"1998"},{"key":"rf15","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(78)90047-7"},{"key":"rf16","doi-asserted-by":"publisher","DOI":"10.1109\/TRA.2003.810578"},{"key":"rf17","doi-asserted-by":"publisher","DOI":"10.1155\/2007\/236106"},{"key":"rf18","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(94)90064-7"},{"key":"rf19","doi-asserted-by":"publisher","DOI":"10.1016\/S0097-8493(99)00155-7"},{"key":"rf20","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-005-3320-7"},{"key":"rf22","first-page":"829","volume":"33","author":"De Groot B. R.","journal-title":"Ann. Biomed. Eng."},{"key":"rf23","doi-asserted-by":"publisher","DOI":"10.1109\/5992.877394"},{"key":"rf24","volume-title":"Robot Analysis \u2014 The Mechanics of Serial and Parallel Manipulators","author":"Tsai L.-W.","year":"1999"},{"key":"rf25","first-page":"1","volume":"26","author":"Inman V. T.","journal-title":"J. Bone Joint Surg."},{"key":"rf29","first-page":"1239","volume":"6","author":"Lenarcic J.","journal-title":"IEEE Trans. Syst. Man Cybernet"},{"key":"rf30","volume-title":"The Shoulder","author":"Codman E. A.","year":"1984"},{"key":"rf34","doi-asserted-by":"publisher","DOI":"10.1109\/70.704227"},{"key":"rf35","doi-asserted-by":"publisher","DOI":"10.1177\/027836499201100504"},{"key":"rf38","first-page":"868","volume":"7","author":"Liegeois A.","journal-title":"IEEE Trans. Syst. Man Cybernet., SMC"},{"key":"rf39","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(80)90170-0"},{"key":"rf40","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2005.02.012"},{"key":"rf41","volume-title":"The Human Figure in Motion","author":"Muybridge E.","year":"1951"},{"key":"rf42","doi-asserted-by":"publisher","DOI":"10.1006\/gmod.2000.0528"},{"key":"rf43","unstructured":"J. M.\u00a0Hollerbach, Robotics Science, ed. M.\u00a0Brady (The MIT Press, Cambridge, 1989)\u00a0pp. 378\u2013431."}],"container-title":["International Journal of Humanoid Robotics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.worldscientific.com\/doi\/pdf\/10.1142\/S0219843608001327","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,4]],"date-time":"2020-05-04T00:44:26Z","timestamp":1588553066000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.worldscientific.com\/doi\/abs\/10.1142\/S0219843608001327"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3]]},"references-count":31,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2011,11,20]]},"published-print":{"date-parts":[[2008,3]]}},"alternative-id":["10.1142\/S0219843608001327"],"URL":"https:\/\/doi.org\/10.1142\/s0219843608001327","relation":{},"ISSN":["0219-8436","1793-6942"],"issn-type":[{"value":"0219-8436","type":"print"},{"value":"1793-6942","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,3]]}}}