{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T04:31:06Z","timestamp":1750307466118,"version":"3.41.0"},"reference-count":11,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2009,7,1]],"date-time":"2009-07-01T00:00:00Z","timestamp":1246406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["SIGBED Rev."],"published-print":{"date-parts":[[2009,7]]},"abstract":"<jats:p>Physiological data is monitored and displayed on medical devices around the world every day, and the volume of this data is steadily increasing and newer monitoring devices enter the clinical setting. However, the vast majority of this data is lost since it is most often displayed once as it is recorded, perhaps replayed one or more times while it exists in the device's volatile memory. What little data that is permanently recorded is most commonly saved through hand written annotations, in paper records and in some limited samples stored on hospital clinical information systems. Meanwhile, current methods of data analysis provide opportunities to utilize this data for improved care of these same critical care patients. A major inhibitor to this becoming reality is the lack of standards for the representation, transmission and storage of physiological data. HL7, for example, does not include definitions for time series data. Research into the use of these data will soon be reaching the clinical setting and the need for such standards to be defined is becoming urgent.<\/jats:p>","DOI":"10.1145\/1859823.1859832","type":"journal-article","created":{"date-parts":[[2010,9,22]],"date-time":"2010-09-22T11:55:58Z","timestamp":1285156558000},"page":"1-6","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Standards for physiological data transmission and archiving for the support of the service of critical care"],"prefix":"10.1145","volume":"6","author":[{"given":"J. Mikael","family":"Eklund","sequence":"first","affiliation":[{"name":"University of Ontario Institute of Technology, Oshawa ON, Canada"}]},{"given":"Carolyn","family":"McGregor","sequence":"additional","affiliation":[{"name":"University of Ontario Institute of Technology, Oshawa ON, Canada"}]}],"member":"320","published-online":{"date-parts":[[2009,7]]},"reference":[{"doi-asserted-by":"crossref","unstructured":"}}M. Stacey C. McGregor and M. Tracy \"An architecture for multi-dimensional abstraction and its application to support neonatal intensive care \" in Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC07) Lyon France 2007 pp. 3752-3756  }}M. Stacey C. McGregor and M. Tracy \"An architecture for multi-dimensional abstraction and its application to support neonatal intensive care \" in Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC07) Lyon France 2007 pp. 3752-3756","key":"e_1_2_1_1_1","DOI":"10.1109\/IEMBS.2007.4353148"},{"volume-title":"IBM Press release","year":"2008","author":"First","key":"e_1_2_1_2_1"},{"doi-asserted-by":"publisher","key":"e_1_2_1_3_1","DOI":"10.1109\/EEE.2005.25"},{"volume-title":"Toward the early diagnosis of neonatal sepsis and sepsis-like illness using novel heart rate analysis. Pediatrics","author":"Griffin P.","key":"e_1_2_1_4_1"},{"volume-title":"A. J. Lyon, and P. Badger, \"Clinical diagnosis of pnneumothorax is late: Use of trend data and decision support might allow preclinical detection,\" Pediatric Research","author":"McIntosh N., J.-C.","key":"e_1_2_1_5_1"},{"volume-title":"Cumulative index of exposure to hypocarbia and hyperoxia as risk factors for periventricular leukomalacia in low birth weight infants,\" Pediatrics","author":"Shankaran S., J. C.","key":"e_1_2_1_6_1"},{"volume-title":"Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC08)","year":"2008","author":"Mikael Eklund","key":"e_1_2_1_7_1"},{"unstructured":"}}Integrated Health Enterprise (IHE) Technical Frameworks Available online http:\/\/www.ihe.net\/Technical_Framework\/  }}Integrated Health Enterprise (IHE) Technical Frameworks Available online http:\/\/www.ihe.net\/Technical_Framework\/","key":"e_1_2_1_8_1"},{"doi-asserted-by":"publisher","key":"e_1_2_1_9_1","DOI":"10.1109\/EEE.2005.51"},{"doi-asserted-by":"publisher","key":"e_1_2_1_10_1","DOI":"10.1109\/IEMBS.2007.4353148"},{"doi-asserted-by":"publisher","key":"e_1_2_1_11_1","DOI":"10.1145\/1266894.1266923"}],"container-title":["ACM SIGBED Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/1859823.1859832","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/1859823.1859832","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T12:08:32Z","timestamp":1750248512000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/1859823.1859832"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,7]]}},"alternative-id":["10.1145\/1859823.1859832"],"URL":"https:\/\/doi.org\/10.1145\/1859823.1859832","relation":{},"ISSN":["1551-3688"],"issn-type":[{"type":"electronic","value":"1551-3688"}],"subject":[],"published":{"date-parts":[[2009,7]]},"assertion":[{"value":"2009-07-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}