{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T16:41:32Z","timestamp":1776012092252,"version":"3.50.1"},"reference-count":19,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2012,6,1]],"date-time":"2012-06-01T00:00:00Z","timestamp":1338508800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["J. Emerg. Technol. Comput. Syst."],"published-print":{"date-parts":[[2012,6]]},"abstract":"<jats:p>The wireless implantable\/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9<jats:italic>\u03bc<\/jats:italic>A from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session.<\/jats:p>","DOI":"10.1145\/2180878.2180883","type":"journal-article","created":{"date-parts":[[2012,6,27]],"date-time":"2012-06-27T13:31:17Z","timestamp":1340803877000},"page":"1-13","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":50,"title":["Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring"],"prefix":"10.1145","volume":"8","author":[{"given":"Steve J. A.","family":"Majerus","sequence":"first","affiliation":[{"name":"Case Western Reserve University"}]},{"given":"Steven L.","family":"Garverick","sequence":"additional","affiliation":[{"name":"Case Western Reserve University"}]},{"given":"Michael A.","family":"Suster","sequence":"additional","affiliation":[{"name":"Case Western Reserve University"}]},{"given":"Paul C.","family":"Fletter","sequence":"additional","affiliation":[{"name":"Louis Stokes Cleveland VA Medical Center"}]},{"given":"Margot S.","family":"Damaser","sequence":"additional","affiliation":[{"name":"Louis Stokes Cleveland VA Medical Center"}]}],"member":"320","published-online":{"date-parts":[[2012,6]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2007.893180"},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1038\/ncpuro0339"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMTT.2008.2007338"},{"key":"e_1_2_1_4_1","volume-title":"Proceedings of the 8th Annual IEEE Conference on Sensors. 1670--1673","author":"Cong P."},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2009.2030982"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/nau.20991"},{"key":"e_1_2_1_7_1","volume-title":"Proceedings of the 6th International Conference on Networked Sensing Systems (INSS09)","author":"Fletter P. C."},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/nau.20039"},{"key":"e_1_2_1_9_1","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1002\/nau.20766","article-title":"Conditional and continuous electrical stimulation increase cystometric capacity in persons with spinal cord injury","volume":"29","author":"Horvath E. E.","year":"2009","journal-title":"Neurourol. Urodyn."},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.sc.3101177"},{"key":"e_1_2_1_11_1","volume-title":"Proceedings of the 5th International Conference on Networked Sensing Systems (INSS08)","author":"Majerus S. J. A."},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2010.2085002"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/4.597305"},{"key":"e_1_2_1_14_1","first-page":"95","article-title":"Short-term effect of pudendal nerve electrical stimulation on detrusor hyper-reflexia in spinal cord injury patients: Importance of current strength","volume":"34","author":"Previnaire J.","year":"1996","journal-title":"Paraplegia"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.1966.4323989"},{"key":"e_1_2_1_16_1","unstructured":"Underwriters Laboratories. 2003. UL 60601-1: Medical Electrical Equipment Part 1: General Requirements for Safety. UL Safety Standard. Underwriters Laboratories . 2003. UL 60601-1: Medical Electrical Equipment Part 1: General Requirements for Safety. UL Safety Standard."},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2008.921601"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(05)00657-9"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)37145-8"}],"container-title":["ACM Journal on Emerging Technologies in Computing Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/2180878.2180883","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/2180878.2180883","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T09:54:22Z","timestamp":1750240462000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/2180878.2180883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,6]]}},"alternative-id":["10.1145\/2180878.2180883"],"URL":"https:\/\/doi.org\/10.1145\/2180878.2180883","relation":{},"ISSN":["1550-4832","1550-4840"],"issn-type":[{"value":"1550-4832","type":"print"},{"value":"1550-4840","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6]]},"assertion":[{"value":"2011-04-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2011-09-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-06-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}