{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T18:34:51Z","timestamp":1759775691255,"version":"3.37.3"},"reference-count":48,"publisher":"Association for Computing Machinery (ACM)","issue":"1","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["#0834797 and #1218505"],"award-info":[{"award-number":["#0834797 and #1218505"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Model. Comput. Simul."],"published-print":{"date-parts":[[2014,1]]},"abstract":"<jats:p>Energy-efficient data center design and management has been a challenge of increasing importance in the past decade due to its potential to save billions of dollars in energy costs. However, the state of the art in design and evaluation of data centers require designers to be expertly familiar with a prohibitively large number of domain-specific design tools that necessitate user intervention in each step of the design process. This is due to the lack of a holistic data center design tool. To fill this gap, this article presents an iterative green data center design framework, the Green Data Center Simulator (GDCSim), for the design and development of energy-efficient data centers.<\/jats:p>","DOI":"10.1145\/2553083","type":"journal-article","created":{"date-parts":[[2014,2,11]],"date-time":"2014-02-11T14:39:42Z","timestamp":1392129582000},"page":"1-27","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":22,"title":["GDCSim"],"prefix":"10.1145","volume":"24","author":[{"given":"Sandeep K. S.","family":"Gupta","sequence":"first","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Ayan","family":"Banerjee","sequence":"additional","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Zahra","family":"Abbasi","sequence":"additional","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Georgios","family":"Varsamopoulos","sequence":"additional","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Michael","family":"Jonas","sequence":"additional","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Joshua","family":"Ferguson","sequence":"additional","affiliation":[{"name":"Arizona State University, Tempe, AZ"}]},{"given":"Rose Robin","family":"Gilbert","sequence":"additional","affiliation":[{"name":"IO Data Centers, Phoenix, AZ"}]},{"given":"Tridib","family":"Mukherjee","sequence":"additional","affiliation":[{"name":"Xerox, Bangalore, India"}]}],"member":"320","published-online":{"date-parts":[[2014,1]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"publisher","DOI":"10.1145\/1851476.1851493"},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1145\/2207222.2207227"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1145\/1736020.1736048"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/65.844498"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1145\/2093698.2093852"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/GREENCOMP.2010.5598306"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.suscom.2011.02.003"},{"key":"e_1_2_1_8_1","volume-title":"IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronics Systems (ITHERM). 445--452","author":"Bash Cullen E.","year":"2006","unstructured":"Cullen E. Bash , Chandrakant D. Patel , and Ratnesh K. Sharma . 2006. Dynamic thermal management of air cooled data centers . In IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronics Systems (ITHERM). 445--452 . DOI: http:\/\/dx.doi.org\/10.1109\/ITHERM. 2006 .1645377 10.1109\/ITHERM.2006.1645377 Cullen E. Bash, Chandrakant D. Patel, and Ratnesh K. Sharma. 2006. Dynamic thermal management of air cooled data centers. In IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronics Systems (ITHERM). 445--452. DOI: http:\/\/dx.doi.org\/10.1109\/ITHERM.2006.1645377"},{"key":"e_1_2_1_9_1","unstructured":"Christian Belady Andy Rawson John Pfleuger and Tahir Cader. 2008. Green grid data center power efficiency metrics: PUE and DCiE. Retrieved from http:\/\/www.thegreengrid.org\/media\/WhitePapers\/White_Paper_6_-_PUE_and_ DCiE_Eff_Metrics_30_December_2008.pdf.  Christian Belady Andy Rawson John Pfleuger and Tahir Cader. 2008. Green grid data center power efficiency metrics: PUE and DCiE. Retrieved from http:\/\/www.thegreengrid.org\/media\/WhitePapers\/White_Paper_6_-_PUE_and_ DCiE_Eff_Metrics_30_December_2008.pdf."},{"key":"e_1_2_1_10_1","volume-title":"Network Operations and Management Symposium (NOMS). 615--622","author":"Chen Yuan","year":"2010","unstructured":"Yuan Chen , D. Gmach , C. Hyser , Z. Wang , C. Bash , C. Hoover , and S. Singhal . 2010. Integrated management of application performance, power and cooling in data centers . In Network Operations and Management Symposium (NOMS). 615--622 . DOI: http:\/\/dx.doi.org\/10.1109\/NOMS. 2010 .5488433 10.1109\/NOMS.2010.5488433 Yuan Chen, D. Gmach, C. Hyser, Z. Wang, C. Bash, C. Hoover, and S. Singhal. 2010. Integrated management of application performance, power and cooling in data centers. In Network Operations and Management Symposium (NOMS). 615--622. DOI: http:\/\/dx.doi.org\/10.1109\/NOMS.2010.5488433"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TC.2008.52"},{"key":"e_1_2_1_12_1","unstructured":"Akhil Docca and Sherman Ikemoto. 2008. Cooling Path Management for the Mission Critical Facility (MCF): A Case Study. White Paper. Retrieved from http:\/\/datacenter.optunity.co.il\/downloads\/CoolingPath_Case_Study_WhitePaper.pdf.  Akhil Docca and Sherman Ikemoto. 2008. Cooling Path Management for the Mission Critical Facility (MCF): A Case Study. White Paper. Retrieved from http:\/\/datacenter.optunity.co.il\/downloads\/CoolingPath_Case_Study_WhitePaper.pdf."},{"key":"e_1_2_1_13_1","volume-title":"USENIX Symposium on Internet Technologies and Systems (USITS)","volume":"4","author":"Elnozahy Mootaz","year":"2003","unstructured":"Mootaz Elnozahy , Michael Kistler , and Ramakrishnan Rajamony . 2003 . Energy conservation policies for web servers . In USENIX Symposium on Internet Technologies and Systems (USITS) , Vol. 4 . Seattle, WA, 8--8. Mootaz Elnozahy, Michael Kistler, and Ramakrishnan Rajamony. 2003. Energy conservation policies for web servers. In USENIX Symposium on Internet Technologies and Systems (USITS), Vol. 4. Seattle, WA, 8--8."},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1145\/1555349.1555368"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/nme.2579"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/IGCC.2011.6008612"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.suscom.2010.10.003"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1145\/1168857.1168872"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10586-008-0070-y"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISORC.2008.25"},{"key":"e_1_2_1_21_1","volume-title":"IEEE International Conference on Cluster Computing and Workshops (CLUSTER). 1--9. DOI: http:\/\/dx.doi.org\/10","author":"Lim Seung-Hwan","year":"2009","unstructured":"Seung-Hwan Lim , B. Sharma , Gunwoo Nam , Eun Kyoung Kim , and C. R. Das . 2009. MDCSim: A multi-tier data center simulation platform . In IEEE International Conference on Cluster Computing and Workshops (CLUSTER). 1--9. DOI: http:\/\/dx.doi.org\/10 .1109\/clustr. 2009 .5289159 10.1109\/clustr.2009.5289159 Seung-Hwan Lim, B. Sharma, Gunwoo Nam, Eun Kyoung Kim, and C. R. Das. 2009. MDCSim: A multi-tier data center simulation platform. In IEEE International Conference on Cluster Computing and Workshops (CLUSTER). 1--9. DOI: http:\/\/dx.doi.org\/10.1109\/clustr.2009.5289159"},{"key":"e_1_2_1_22_1","unstructured":"Liz Marshall and Paul Bemis. 2011. Using CFD for Data Center Design and Analysis. White Paper. Retrieved from http:\/\/www.coolsimsoftware.com\/Portals\/0\/PDF\/WP107_CFD_for_Data_Centers.pdf.  Liz Marshall and Paul Bemis. 2011. Using CFD for Data Center Design and Analysis. White Paper. Retrieved from http:\/\/www.coolsimsoftware.com\/Portals\/0\/PDF\/WP107_CFD_for_Data_Centers.pdf."},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1145\/1508284.1508269"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1145\/2000064.2000103"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISPASS.2011.5762723"},{"key":"e_1_2_1_26_1","volume-title":"USENIX Annual Technical Conference. 5.","author":"Moore Justin","year":"2005","unstructured":"Justin Moore , Jeff Chase , Parthasarathy Ranganathan , and Ratnesh Sharma . 2005 . Making scheduling cool: Temperature-aware workload placement in data centers . In USENIX Annual Technical Conference. 5. Justin Moore, Jeff Chase, Parthasarathy Ranganathan, and Ratnesh Sharma. 2005. Making scheduling cool: Temperature-aware workload placement in data centers. In USENIX Annual Technical Conference. 5."},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICAC.2006.1662394"},{"key":"e_1_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.comnet.2010.08.011"},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.comnet.2009.06.008"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.5555\/1387589.1387612"},{"key":"e_1_2_1_31_1","doi-asserted-by":"crossref","unstructured":"Ehsan Pakbaznia Mohammad Ghasemazar and Massoud Pedram. 2010. Temperature-aware dynamic resource provisioning in a power-optimized datacenter. In Design Automation and Test in Europe (DATE). 124--129.   Ehsan Pakbaznia Mohammad Ghasemazar and Massoud Pedram. 2010. Temperature-aware dynamic resource provisioning in a power-optimized datacenter. In Design Automation and Test in Europe (DATE). 124--129.","DOI":"10.1109\/DATE.2010.5457223"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1145\/1594233.1594268"},{"volume-title":"Numerical Heat Transfer and Fluid Flow","author":"Patankar Suhar V.","key":"e_1_2_1_33_1","unstructured":"Suhar V. Patankar . 1980. Numerical Heat Transfer and Fluid Flow . Taylor & Francis . Suhar V. Patankar. 1980. Numerical Heat Transfer and Fluid Flow. Taylor & Francis."},{"key":"e_1_2_1_34_1","volume-title":"ASME International Electronic Packaging Technical Conference and Exhibition (IPACK).","author":"Patel Chandrakant","year":"2001","unstructured":"Chandrakant Patel , Cullen E. Bash , Christian Belady , Lennart Stahl , and Danny Sullivan . 2001 . Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications . In ASME International Electronic Packaging Technical Conference and Exhibition (IPACK). Chandrakant Patel, Cullen E. Bash, Christian Belady, Lennart Stahl, and Danny Sullivan. 2001. Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications. In ASME International Electronic Packaging Technical Conference and Exhibition (IPACK)."},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1109\/ITHERM.2002.1012532"},{"key":"e_1_2_1_36_1","volume-title":"ERE: A Metric for Measuring the Benefit of Reuse Energy from a Data Center.","author":"Patterson Michael","year":"2010","unstructured":"Michael Patterson , Bill Tschudi , Otto Vangeet , Dan Azevedo , and Jud Cooley . 2010 . ERE: A Metric for Measuring the Benefit of Reuse Energy from a Data Center. Retrieved from http:\/\/www.thegreengrid.org\/media\/WhitePapers\/ERE_WP_101510_v2.pdf. Michael Patterson, Bill Tschudi, Otto Vangeet, Dan Azevedo, and Jud Cooley. 2010. ERE: A Metric for Measuring the Benefit of Reuse Energy from a Data Center. Retrieved from http:\/\/www.thegreengrid.org\/media\/WhitePapers\/ERE_WP_101510_v2.pdf."},{"volume-title":"Workshop on Energy-Efficient Design (WEED)","author":"Pelley Steven","key":"e_1_2_1_37_1","unstructured":"Steven Pelley , David Meisner , Thomas F. Wenisch , and James W . VanGilder. 2009. Understanding and abstracting total data center power . In Workshop on Energy-Efficient Design (WEED) . Austin, TX. Steven Pelley, David Meisner, Thomas F. Wenisch, and James W. VanGilder. 2009. Understanding and abstracting total data center power. In Workshop on Energy-Efficient Design (WEED). Austin, TX."},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1145\/1346281.1346289"},{"key":"e_1_2_1_39_1","volume-title":"IEEE International Symposium on High Performance Computer Architecture (HPCA). 111--122","author":"Luiz","year":"2008","unstructured":"Luiz E. Ramos and Ricardo Bianchini. 2008. C-Oracle: Predictive thermal management for data centers . In IEEE International Symposium on High Performance Computer Architecture (HPCA). 111--122 . DOI: http:\/\/dx.doi.org\/10.1109\/HPCA. 2008 .4658632 10.1109\/HPCA.2008.4658632 Luiz E. Ramos and Ricardo Bianchini. 2008. C-Oracle: Predictive thermal management for data centers. In IEEE International Symposium on High Performance Computer Architecture (HPCA). 111--122. DOI: http:\/\/dx.doi.org\/10.1109\/HPCA.2008.4658632"},{"key":"e_1_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISCA.2006.20"},{"key":"e_1_2_1_41_1","volume-title":"USENIX Conference on Sustainable information technology (SustainIT). 6--6.","author":"Singh Umesh","year":"2010","unstructured":"Umesh Singh , Amarendra K. Singh , Parvez S., and Anand Sivasubramaniam . 2010 . CFD-based operational thermal efficiency improvement of a production ata center . In USENIX Conference on Sustainable information technology (SustainIT). 6--6. Umesh Singh, Amarendra K. Singh, Parvez S., and Anand Sivasubramaniam. 2010. CFD-based operational thermal efficiency improvement of a production ata center. In USENIX Conference on Sustainable information technology (SustainIT). 6--6."},{"key":"e_1_2_1_43_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPDS.2008.111"},{"key":"e_1_2_1_44_1","doi-asserted-by":"publisher","DOI":"10.1145\/2331147.2331167"},{"key":"e_1_2_1_45_1","volume-title":"International Conference on Intelligent Sensing and Information Processing. 203--208","author":"Tang Qinghui","year":"2006","unstructured":"Qinghui Tang , Tridib Mukherjee , Sandeep K. S. Gupta , and Phil Cayton . 2006 . Sensor-based fast thermal evaluation model for energy efficient high-performance data centers . In International Conference on Intelligent Sensing and Information Processing. 203--208 . Qinghui Tang, Tridib Mukherjee, Sandeep K. S. Gupta, and Phil Cayton. 2006. Sensor-based fast thermal evaluation model for energy efficient high-performance data centers. In International Conference on Intelligent Sensing and Information Processing. 203--208."},{"key":"e_1_2_1_46_1","doi-asserted-by":"publisher","DOI":"10.1145\/1342171.1342172"},{"volume-title":"International Conference on High Performance Computing Conference (HiPC). 1--11","author":"Varsamopoulos Georgios","key":"e_1_2_1_47_1","unstructured":"Georgios Varsamopoulos , Zahra Abbasi , and Sandeep K. S. Gupta . 2010. Trends and effects of energy proportionality on server provisioning in data centers . In International Conference on High Performance Computing Conference (HiPC). 1--11 . Georgios Varsamopoulos, Zahra Abbasi, and Sandeep K. S. Gupta. 2010. Trends and effects of energy proportionality on server provisioning in data centers. In International Conference on High Performance Computing Conference (HiPC). 1--11."},{"key":"e_1_2_1_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.suscom.2013.01.008"},{"key":"e_1_2_1_49_1","unstructured":"H. Versteeg and W. Malalasekera. 2007. An Introduction to Computational Fluid Dynamics: The Finite Volume Method. Prentice Hall.  H. Versteeg and W. Malalasekera. 2007. An Introduction to Computational Fluid Dynamics: The Finite Volume Method. Prentice Hall."}],"container-title":["ACM Transactions on Modeling and Computer Simulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/2553083","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,30]],"date-time":"2022-12-30T20:57:49Z","timestamp":1672433869000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/2553083"}},"subtitle":["A simulator for green data center design and analysis"],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":48,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,1]]}},"alternative-id":["10.1145\/2553083"],"URL":"https:\/\/doi.org\/10.1145\/2553083","relation":{},"ISSN":["1049-3301","1558-1195"],"issn-type":[{"type":"print","value":"1049-3301"},{"type":"electronic","value":"1558-1195"}],"subject":[],"published":{"date-parts":[[2014,1]]},"assertion":[{"value":"2011-01-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-10-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-01-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}