{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T07:44:38Z","timestamp":1761896678824,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":31,"publisher":"ACM","license":[{"start":{"date-parts":[[2018,1,4]],"date-time":"2018-01-04T00:00:00Z","timestamp":1515024000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,1,4]]},"DOI":"10.1145\/3154273.3154328","type":"proceedings-article","created":{"date-parts":[[2018,1,12]],"date-time":"2018-01-12T13:49:57Z","timestamp":1515764997000},"page":"1-10","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Opportunistic Power Savings with Coordinated Control in Data Center Networks"],"prefix":"10.1145","author":[{"given":"Madhurima","family":"Ray","sequence":"first","affiliation":[{"name":"Computer and Information Sciences, Temple University, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanjeev","family":"Sondur","sequence":"additional","affiliation":[{"name":"Computer and Information Sciences, Temple University, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joyanta","family":"Biswas","sequence":"additional","affiliation":[{"name":"Computer and Information Sciences, Temple University, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amitangshu","family":"Pal","sequence":"additional","affiliation":[{"name":"Computer and Information Sciences, Temple University, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Krishna","family":"Kant","sequence":"additional","affiliation":[{"name":"Computer and Information Sciences, Temple University, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2018,1,4]]},"reference":[{"key":"e_1_3_2_1_1_1","unstructured":"Caida data server. http:\/\/data.caida.org\/datasets\/passive\/passive-oc48\/20020814-160000.UTC\/pcap\/.  Caida data server. http:\/\/data.caida.org\/datasets\/passive\/passive-oc48\/20020814-160000.UTC\/pcap\/."},{"key":"e_1_3_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1145\/1816038.1816004"},{"key":"e_1_3_2_1_3_1","first-page":"19","volume-title":"USENIX NSDI","year":"2010","unstructured":"Al-Fares : Dynamic flow scheduling for data center networks . In USENIX NSDI , pages 19 -- 19 , 2010 . Al-Fares et al. Hedera: Dynamic flow scheduling for data center networks. In USENIX NSDI, pages 19--19, 2010."},{"key":"e_1_3_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/LCN.2007.32"},{"key":"e_1_3_2_1_5_1","volume-title":"Report to Congress on Server and Data Center Energy Efficiency: Public Law 109--431.","author":"Brown R. E.","year":"2007","unstructured":"R. E. Brown , R. Brown , E. Masanet , B. Nordman , B. Tschudi , A. Shehabi , J. Stanley , J. Koomey , D. Sartor , P. Chan , and E. I. U. E. P. A. et al. with Alliance to Save Energy , ICF Incorporated. Report to Congress on Server and Data Center Energy Efficiency: Public Law 109--431. 2007 . R. E. Brown, R. Brown, E. Masanet, B. Nordman, B. Tschudi, A. Shehabi, J. Stanley, J. Koomey, D. Sartor, P. Chan, and E. I. U. E. P. A. et al. with Alliance to Save Energy, ICF Incorporated. Report to Congress on Server and Data Center Energy Efficiency: Public Law 109--431. 2007."},{"key":"e_1_3_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2010.5621967"},{"key":"e_1_3_2_1_7_1","doi-asserted-by":"crossref","unstructured":"Erickson \n  Using Network Knowledge to Improve Workload Performance in Virtualized Data Centers\n  . PhD thesis Stanford University 2013\n  .  Erickson et al. Using Network Knowledge to Improve Workload Performance in Virtualized Data Centers. PhD thesis Stanford University 2013.","DOI":"10.1109\/IC2E.2014.81"},{"key":"e_1_3_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1145\/3034950.3035000"},{"key":"e_1_3_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1145\/1496091.1496103"},{"key":"e_1_3_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/INFCOM.2007.299"},{"key":"e_1_3_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/IPDPS.2013.100"},{"key":"e_1_3_2_1_12_1","volume-title":"Proc. of COMSNET, 01","author":"Kant K.","year":"2011","unstructured":"K. Kant . Multistate power management of communications links . In Proc. of COMSNET, 01 2011 . K. Kant. Multistate power management of communications links. In Proc. of COMSNET, 01 2011."},{"key":"e_1_3_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/PCCC.2014.7017088"},{"key":"e_1_3_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1145\/1555312.1555319"},{"key":"e_1_3_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2011.5978421"},{"key":"e_1_3_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.5555\/1833515.1833690"},{"key":"e_1_3_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/LCOMM.2015.2461161"},{"key":"e_1_3_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1049\/el.2015.4156"},{"key":"e_1_3_2_1_19_1","volume-title":"On the interconnect energy efficiency of high end computing systems","author":"Murugan M.","year":"2012","unstructured":"M. Murugan On the interconnect energy efficiency of high end computing systems . Sustainable Computing : Informatics and Systems , April 2012 . M. Murugan et al. On the interconnect energy efficiency of high end computing systems. Sustainable Computing: Informatics and Systems, April 2012."},{"key":"e_1_3_2_1_20_1","first-page":"323","volume-title":"USENIX NSDI","year":"2008","unstructured":"Nedevschi Reducing network energy consumption via sleeping and rate-adaptation . In USENIX NSDI , pages 323 -- 336 , 2008 . Nedevschi et al. Reducing network energy consumption via sleeping and rate-adaptation. In USENIX NSDI, pages 323--336, 2008."},{"key":"e_1_3_2_1_21_1","unstructured":"IEEE Transactions on Cloud Computing 2015 Energy-aware load balancing and application scaling for the cloud ecosystem"},{"key":"e_1_3_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/MASSP.1986.1165342"},{"key":"e_1_3_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1145\/1346281.1346289"},{"key":"e_1_3_2_1_24_1","first-page":"15","volume-title":"The ns-3 network simulator. Modeling and tools for network simulation","year":"2010","unstructured":"Riley The ns-3 network simulator. Modeling and tools for network simulation , pages 15 -- 34 , 2010 . Riley et al. The ns-3 network simulator. Modeling and tools for network simulation, pages 15--34, 2010."},{"key":"e_1_3_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/LCN.2010.5735719"},{"key":"e_1_3_2_1_26_1","unstructured":"Sondur etal Implementing data center energy management capabilities in ns3. In publication.  Sondur et al. Implementing data center energy management capabilities in ns3. In publication."},{"key":"e_1_3_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICCW.2015.7247610"},{"key":"e_1_3_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.future.2006.03.007"},{"key":"e_1_3_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.5555\/1496950.1496966"},{"key":"e_1_3_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1109\/INFCOM.2012.6195471"},{"key":"e_1_3_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/INFOCOM.2014.6848207"}],"event":{"name":"ICDCN '18: 19th International Conference on Distributed Computing and Networking","sponsor":["SIGMOBILE ACM Special Interest Group on Mobility of Systems, Users, Data and Computing","SIGOPS ACM Special Interest Group on Operating Systems"],"location":"Varanasi India","acronym":"ICDCN '18"},"container-title":["Proceedings of the 19th International Conference on Distributed Computing and Networking"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3154273.3154328","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3154273.3154328","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T02:11:26Z","timestamp":1750212686000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3154273.3154328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,4]]},"references-count":31,"alternative-id":["10.1145\/3154273.3154328","10.1145\/3154273"],"URL":"https:\/\/doi.org\/10.1145\/3154273.3154328","relation":{},"subject":[],"published":{"date-parts":[[2018,1,4]]},"assertion":[{"value":"2018-01-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}