{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T22:20:09Z","timestamp":1780093209545,"version":"3.54.0"},"publisher-location":"New York, NY, USA","reference-count":26,"publisher":"ACM","license":[{"start":{"date-parts":[[2018,4,21]],"date-time":"2018-04-21T00:00:00Z","timestamp":1524268800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,4,21]]},"DOI":"10.1145\/3173574.3173999","type":"proceedings-article","created":{"date-parts":[[2018,4,20]],"date-time":"2018-04-20T15:38:35Z","timestamp":1524238715000},"page":"1-9","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":96,"title":["Seismo"],"prefix":"10.1145","author":[{"given":"Edward Jay","family":"Wang","sequence":"first","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junyi","family":"Zhu","sequence":"additional","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohit","family":"Jain","sequence":"additional","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tien-Jui","family":"Lee","sequence":"additional","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elliot","family":"Saba","sequence":"additional","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lama","family":"Nachman","sequence":"additional","affiliation":[{"name":"Intel Labs, Santa Clara, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shwetak N.","family":"Patel","sequence":"additional","affiliation":[{"name":"University of Washington, Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2018,4,21]]},"reference":[{"key":"e_1_3_2_2_1_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.110.160911"},{"key":"e_1_3_2_2_2_1","volume-title":"Pulse transit times to the capillary bed evaluated by laser Doppler flowmetry. (Mar","author":"Bernjak A","year":"2009","unstructured":"A Bernjak and A Stefanovska. 2009. Pulse transit times to the capillary bed evaluated by laser Doppler flowmetry. (Mar 2009). https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19202235"},{"key":"e_1_3_2_2_3_1","doi-asserted-by":"publisher","DOI":"10.1145\/3130905"},{"key":"e_1_3_2_2_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2012.2211078"},{"key":"e_1_3_2_2_5_1","volume-title":"IEEE International Workshop on Medical Measurements and Applications. 10--13","author":"Fortino G.","unstructured":"G. Fortino and V. Giampa. 2010. PPG-based methods for non invasive and continuous blood pressure measurement: an overview and development issues in body sensor networks. In IEEE International Workshop on Medical Measurements and Applications. 10--13."},{"key":"e_1_3_2_2_6_1","doi-asserted-by":"publisher","DOI":"10.1145\/3132024"},{"key":"e_1_3_2_2_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2014.2361732"},{"key":"e_1_3_2_2_8_1","doi-asserted-by":"publisher","DOI":"10.1109\/DSD.2015.90"},{"key":"e_1_3_2_2_9_1","volume-title":"International Symposium on Circuits and Systems (ISCAS). 1006--1009","author":"Kachuee M.","unstructured":"M. Kachuee, M. M. Kiani, H. Mohammadzade, and M. Shabany. 2015. Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In International Symposium on Circuits and Systems (ISCAS). 1006--1009."},{"key":"e_1_3_2_2_10_1","volume-title":"Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring","author":"Kim Chang-Sei","year":"2015","unstructured":"Chang-Sei Kim, Andrew M. Carek, Ramakrishna Mukkamala, Omer T. Inan, and Jin-Oh Hahn. 2015. Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring. IEEE transactions on bio-medical engineering (Nov 2015). https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC4626385\/"},{"key":"e_1_3_2_2_11_1","volume-title":"E-Health and Bioengineering Conference (EHB). 241--244","author":"Landreani F.","unstructured":"F. Landreani, M. Morri, A. Martin-Yebra, C. Casellato, E. Pavan, C. Frigo, and E. G. Caiani. 2017. Ultra-short-term heart rate variability analysis on accelerometric signals from mobile phone. In E-Health and Bioengineering Conference (EHB). 241--244."},{"key":"e_1_3_2_2_12_1","volume-title":"Pulse transit time and blood pressure: an intensive analysis. Psychophysiology. (Jan","author":"Lane J D","year":"1983","unstructured":"J D Lane, L Greenstadt, D Shapiro, and E Rubinstein. 1983. Pulse transit time and blood pressure: an intensive analysis. Psychophysiology. (Jan 1983). https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/6828611"},{"key":"e_1_3_2_2_13_1","doi-asserted-by":"crossref","unstructured":"He Liu Kamen Ivanov Yadong Wang and Lei Wang. 2015. Toward a Smartphone Application for Estimation of Pulse Transit Time. In Sensors.","DOI":"10.3390\/s151027303"},{"key":"e_1_3_2_2_14_1","volume-title":"The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. Psychophysiology. (Sep","author":"Marie G V","year":"1984","unstructured":"G V Marie, C R Lo, J Van, and D W Johnston. 1984. The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. Psychophysiology. (Sep 1984). https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/6473621"},{"key":"e_1_3_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.1145\/3132028"},{"key":"e_1_3_2_2_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2015.2441951"},{"key":"e_1_3_2_2_17_1","volume-title":"Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement. Blood pressure 24, 4 (April","author":"Patzak Andreas","year":"2015","unstructured":"Andreas Patzak, Yuri Mendoza, Heiko Gesche, and Martin Konermann. 2015. Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement. Blood pressure 24, 4 (April 2015), 217--221."},{"key":"e_1_3_2_2_18_1","volume-title":"Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals. Sensors 15, 9","author":"Peng Rong-Chao","year":"2015","unstructured":"Rong-Chao Peng, Wen-Rong Yan, Ning-Ling Zhang, Wan-Hua Lin, Xiao-Lin Zhou, and Yuan-Ting Zhang. 2015. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals. Sensors 15, 9 (2015), 23653S23666."},{"key":"e_1_3_2_2_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjhyper.2004.09.006"},{"key":"e_1_3_2_2_20_1","doi-asserted-by":"crossref","unstructured":"J. Talts R. Raamat K. Jagom\u00e4gi and J. Kivastik. 2011. An Influence of Multiple Affecting Factors on Characteristic Ratios of Oscillometric Blood Pressure Measurement. Springer Berlin Heidelberg Berlin Heidelberg 73--76.","DOI":"10.1007\/978-3-642-21683-1_18"},{"key":"e_1_3_2_2_21_1","volume-title":"Retrieved","author":"WHO.","year":"2017","unstructured":"WHO. 2017. Global Health Observatory (GHO) data: Raised blood pressure. (2017). Retrieved May 30, 2017 from http:\/\/www.who.int\/gho\/ncd\/risk_factors\/blood_pressure_prevalence_text\/en\/"},{"key":"e_1_3_2_2_22_1","volume-title":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2724--2727","author":"Winokur E. S.","unstructured":"E. S. Winokur, D. D. He, and C. G. Sodini. 2012. A wearable vital signs monitor at the ear for continuous heart rate and Pulse Transit Time measurements. In Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2724--2727."},{"key":"e_1_3_2_2_23_1","volume-title":"Carmen Chung-Yan Poon, and Yuan-Ting Zhang","author":"Yee-Man Wong Mico","year":"2009","unstructured":"Mico Yee-Man Wong, Carmen Chung-Yan Poon, and Yuan-Ting Zhang. 2009. An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects. Cardiovascular Engineering 9, 1 (01 Mar 2009), 32--38."},{"key":"e_1_3_2_2_24_1","first-page":"1","article-title":"Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison","volume":"99","author":"Yang C.","year":"2017","unstructured":"C. Yang and N. Tavassolian. 2017. Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison. IEEE Journal of Biomedical and Health Informatics PP, 99 (2017), 1--1.","journal-title":"IEEE Journal of Biomedical and Health Informatics PP"},{"key":"e_1_3_2_2_25_1","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00980.2011"},{"key":"e_1_3_2_2_26_1","volume-title":"Radial pulse transit time is an index of arterial stiffness. Hypertension research : official journal of the Japanese Society of Hypertension. (Jul","author":"Zhang Y L","year":"2011","unstructured":"Y L Zhang, Y Y Zheng, Z C Ma, and Y N Sun. 2011b. Radial pulse transit time is an index of arterial stiffness. Hypertension research : official journal of the Japanese Society of Hypertension. (Jul 2011). https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/21593741"}],"event":{"name":"CHI '18: CHI Conference on Human Factors in Computing Systems","location":"Montreal QC Canada","acronym":"CHI '18","sponsor":["SIGCHI ACM Special Interest Group on Computer-Human Interaction"]},"container-title":["Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3173574.3173999","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3173574.3173999","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T01:08:37Z","timestamp":1750208917000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3173574.3173999"}},"subtitle":["Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera"],"short-title":[],"issued":{"date-parts":[[2018,4,21]]},"references-count":26,"alternative-id":["10.1145\/3173574.3173999","10.1145\/3173574"],"URL":"https:\/\/doi.org\/10.1145\/3173574.3173999","relation":{},"subject":[],"published":{"date-parts":[[2018,4,21]]},"assertion":[{"value":"2018-04-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}