{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T19:31:23Z","timestamp":1795203083867,"version":"4.10.3"},"reference-count":57,"publisher":"Association for Computing Machinery (ACM)","issue":"1","license":[{"start":{"date-parts":[[2018,3,26]],"date-time":"2018-03-26T00:00:00Z","timestamp":1522022400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2018,3,26]]},"abstract":"<jats:p>Nowadays, considerable number of devices have been proposed to monitor cardiovascular health. To protect medical data on these devices from unauthorized access, researchers have proposed ECG-based and heart sound-based authentication methods. However, their vulnerabilities to replay attacks have recently been revealed. In this paper, we leverage liveness detection to enhance heart sound-based authentication against replay attacks. We utilize the inherent correlation between sounds and chest motion caused by deep breathing to realize a reliable liveness detection system, BreathLive. To be specific, BreathLive captures breathing sounds and chest motion simultaneously, and then eliminates signal delay caused by any imperfections of device components. Next, it extracts a set of features to characterize the correlation between sounds and motion signals, and uses them to train the classifier. We implement and evaluated BreathLive under different attacking scenarios and contexts. The results show that BreathLive achieves an equal error rate of 4.0%, 6.4% and 8.3% for random impersonation attacks, advanced impersonation attacks and advanced replay attacks respectively, which indicates its effectiveness in defending against different attacks. Also the extensive experiments prove the system can be robust to different contexts with a small training set.<\/jats:p>","DOI":"10.1145\/3191744","type":"journal-article","created":{"date-parts":[[2018,3,27]],"date-time":"2018-03-27T12:06:45Z","timestamp":1522152405000},"page":"1-25","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":30,"title":["BreathLive"],"prefix":"10.1145","volume":"2","author":[{"given":"Chenyu","family":"Huang","sequence":"first","affiliation":[{"name":"Hong Kong University of Science and Technology, ClearWater Bay, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huangxun","family":"Chen","sequence":"additional","affiliation":[{"name":"Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Yang","sequence":"additional","affiliation":[{"name":"Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, Noah's Ark Lab, Huawei Technologies, Shen Zhen, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Zhang","sequence":"additional","affiliation":[{"name":"Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2018,3,26]]},"reference":[{"key":"e_1_2_1_1_1","unstructured":"2011. Nymi | Convenient Authentication Anywhere. https:\/\/nymi.com\/. (2011)."},{"key":"e_1_2_1_2_1","unstructured":"2016. APPLE WATCH SERIES 2. https:\/\/www.apple.com\/hk\/en\/watch\/. (2016)."},{"key":"e_1_2_1_3_1","unstructured":"2016. SEEQ Mobile Cardiac Telemetry System. http:\/\/www.medtronicdiagnostics.com\/us\/cardiac-monitors\/seeq-mct-system\/index.htm. (2016)."},{"key":"e_1_2_1_4_1","unstructured":"2017. 3M Littmann Electronic Stethoscope Model 3200. http:\/\/www.littmann.com\/3M\/en_US\/littmann-stethoscopes\/products\/~\/3M-Littmann-Electronic-Stethoscope-Model-3200?N=5932256+8711017+32931883928rt=rud. (2017)."},{"key":"e_1_2_1_5_1","unstructured":"2017. Breathing- Wikipedia. https:\/\/en.wikipedia.org\/wiki\/Breathing. (2017)."},{"key":"e_1_2_1_6_1","unstructured":"2017. Diaphragmatic breathing- Wikipedia. https:\/\/en.wikipedia.org\/wiki\/Diaphragmatic_breathing. (2017)."},{"key":"e_1_2_1_7_1","unstructured":"2017. How safe is your fitness tracker? Hackers could steal your data and sell the information to health companies. http:\/\/www.dailymail.co.uk\/sciencetech\/article-4049154\/How-safe-fitness-tracker-Hackers-steal-data-sell-information-health-companies.html. (2017)."},{"key":"e_1_2_1_8_1","unstructured":"2017. POLAR H10 HEART RATE SENSOR. https:\/\/www.polar.com\/hk-en\/products\/accessories\/h10_heart_rate_sensor. (2017)."},{"key":"e_1_2_1_9_1","unstructured":"2017. Samsung Galaxy S8 | S8+. http:\/\/www.samsung.com\/global\/galaxy\/galaxy-s8\/. (2017)."},{"key":"e_1_2_1_10_1","unstructured":"2017. Thinklabs One - Digital stethoscope. http:\/\/www.thinklabs.com. (2017)."},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/INFOCOM.2016.7524401"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/11551201_4"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2010.2061846"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/BSN.2010.50"},{"key":"e_1_2_1_15_1","volume-title":"Human identity verification based on heart sounds: recent advances and future directions. arXiv preprint arXiv:1105.4058","author":"Beritelli Francesco","year":"2011","unstructured":"Francesco Beritelli and Andrea Spadaccini. 2011. Human identity verification based on heart sounds: recent advances and future directions. arXiv preprint arXiv:1105.4058 (2011)."},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/0167-8760(94)90027-2"},{"key":"e_1_2_1_17_1","volume-title":"Crackle sounds analysis by empirical mode decomposition","author":"Charleston-Villalobos Sonia","year":"2007","unstructured":"Sonia Charleston-Villalobos, Ram\u00f3n Gonz\u00e1lez-Camarena, Georgina Chi-Lem, and Tom\u00e1s Aljama-Corrales. 2007. Crackle sounds analysis by empirical mode decomposition. IEEE Engineering in medicine and biology magazine 26, 1 (2007), 40."},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1145\/3081333.3081355"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICDCS.2017.133"},{"key":"e_1_2_1_20_1","volume-title":"Proc. Image and Vision Computing","author":"Chetty Girija","year":"2004","unstructured":"Girija Chetty and Michael Wagner. 2004. Automated lip feature extraction for liveness verification in audio-video authentication. Proc. Image and Vision Computing (2004), 17--22."},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.5555\/3068615.3068625"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TASL.2012.2201472"},{"key":"e_1_2_1_23_1","volume-title":"International Conference on Security and Privacy in Mobile Information and Communication Systems. Springer, 136--147","author":"Derawi Mohammad Omar","year":"2011","unstructured":"Mohammad Omar Derawi, Bian Yang, and Christoph Busch. 2011. Fingerprint recognition with embedded cameras on mobile phones. In International Conference on Security and Privacy in Mobile Information and Communication Systems. Springer, 136--147."},{"key":"e_1_2_1_24_1","doi-asserted-by":"crossref","unstructured":"Simon Eberz Nicola Paoletti Marc Roeschlin Marta Kwiatkowska I Martinovic and A Patan\u00e9. 2017. Broken hearted: How to attack ECG biometrics. (2017).","DOI":"10.14722\/ndss.2017.23408"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1145\/2858036.2858401"},{"key":"e_1_2_1_26_1","volume-title":"The relationship between normal lung sounds, age, and gender. American journal of respiratory and critical care medicine 162, 3","author":"Gross Volker","year":"2000","unstructured":"Volker Gross, Anke Dittmar, Thomas Penzel, Frank Schuttler, and Peter Von Wichert. 2000. The relationship between normal lung sounds, age, and gender. American journal of respiratory and critical care medicine 162, 3 (2000), 905--909."},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.5555\/2904392"},{"key":"e_1_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10916-005-5182-9"},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1109\/LSP.2003.817171"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1145\/2517351.2517359"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2003.820359"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/0471722146"},{"key":"e_1_2_1_33_1","unstructured":"Chih-Wei Hsu Chih-Chung Chang Chih-Jen Lin et al. 2003. A practical guide to support vector classification. (2003)."},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.86.2.225"},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1145\/2370216.2370261"},{"key":"e_1_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.1145\/2030112.2030163"},{"key":"e_1_2_1_37_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMC.2015.2504935"},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1145\/2968219.2971394"},{"key":"e_1_2_1_39_1","doi-asserted-by":"publisher","DOI":"10.5555\/2671225.2671292"},{"key":"e_1_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1186\/2193-1801-2-512"},{"key":"e_1_2_1_41_1","first-page":"1490","article-title":"Automated lung sound analysis in patients with pneumonia","volume":"49","author":"Murphy Raymond LH","year":"2004","unstructured":"Raymond LH Murphy, Andrey Vyshedskiy, Verna-Ann Power-Charnitsky, Dhirendra S Bana, Patricia M Marinelli, Anna Wong-Tse, and Rozanne Paciej. 2004. Automated lung sound analysis in patients with pneumonia. Respiratory Care 49, 12 (2004), 1490--1497.","journal-title":"Respiratory Care"},{"key":"e_1_2_1_42_1","doi-asserted-by":"publisher","DOI":"10.1145\/2742647.2742674"},{"key":"e_1_2_1_43_1","doi-asserted-by":"publisher","DOI":"10.1145\/2594368.2594386"},{"key":"e_1_2_1_44_1","volume-title":"Biosignal and medical image processing","author":"Semmlow John L","unstructured":"John L Semmlow and Benjamin Griffel. 2014. Biosignal and medical image processing. CRC press."},{"key":"e_1_2_1_45_1","doi-asserted-by":"publisher","DOI":"10.1109\/ELECO.2015.7394532"},{"key":"e_1_2_1_46_1","doi-asserted-by":"publisher","DOI":"10.1145\/2750858.2805826"},{"key":"e_1_2_1_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2006.09.007"},{"key":"e_1_2_1_48_1","doi-asserted-by":"publisher","DOI":"10.5555\/1987476.1987508"},{"key":"e_1_2_1_49_1","doi-asserted-by":"publisher","DOI":"10.1109\/CCST.2011.6095943"},{"key":"e_1_2_1_50_1","volume-title":"Ilse Van Diest, and Omer Van den Bergh","author":"Vlemincx Elke","year":"2013","unstructured":"Elke Vlemincx, James L Abelson, Paul M Lehrer, Paul W Davenport, Ilse Van Diest, and Omer Van den Bergh. 2013. Respiratory variability and sighing: a psychophysiological reset model. Biological psychology 93, 1 (2013), 24--32."},{"key":"e_1_2_1_51_1","doi-asserted-by":"publisher","DOI":"10.1145\/2971648.2971744"},{"key":"e_1_2_1_52_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICMLC.2011.6016982"},{"key":"e_1_2_1_53_1","volume-title":"Automatic breath and snore sounds classification from tracheal and ambient sounds recordings. Medical engineering 8 physics 32, 9","author":"Yadollahi Azadeh","year":"2010","unstructured":"Azadeh Yadollahi and Zahra Moussavi. 2010. Automatic breath and snore sounds classification from tracheal and ambient sounds recordings. Medical engineering 8 physics 32, 9 (2010), 985--990."},{"key":"e_1_2_1_54_1","doi-asserted-by":"publisher","DOI":"10.1145\/2370216.2370269"},{"key":"e_1_2_1_55_1","volume-title":"Effect of airflow rate on vibration response imaging in normal lungs. The open respiratory medicine journal 3","author":"Yosef Meirav","year":"2009","unstructured":"Meirav Yosef, Ruben Langer, Shaul Lev, and Yael A Glickman. 2009. Effect of airflow rate on vibration response imaging in normal lungs. The open respiratory medicine journal 3 (2009), 116."},{"key":"e_1_2_1_56_1","volume-title":"Bio-Inspired Inertial Sensors for Human Body Motion Measurement","author":"Zeng Hansong","unstructured":"Hansong Zeng. 2012. Bio-Inspired Inertial Sensors for Human Body Motion Measurement. The Ohio State University."},{"key":"e_1_2_1_57_1","doi-asserted-by":"publisher","DOI":"10.1145\/2976749.2978296"}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3191744","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3191744","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T02:26:42Z","timestamp":1750213602000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3191744"}},"subtitle":["Liveness Detection for Heart Sound Authentication with Deep Breathing"],"short-title":[],"issued":{"date-parts":[[2018,3,26]]},"references-count":57,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,3,26]]}},"alternative-id":["10.1145\/3191744"],"URL":"https:\/\/doi.org\/10.1145\/3191744","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,26]]},"assertion":[{"value":"2017-08-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-01-01","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-03-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}