{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T14:34:29Z","timestamp":1772462069180,"version":"3.50.1"},"reference-count":34,"publisher":"Association for Computing Machinery (ACM)","issue":"4","license":[{"start":{"date-parts":[[2018,6,28]],"date-time":"2018-06-28T00:00:00Z","timestamp":1530144000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"name":"UC MEXUS-CONACYT Collaborative Research","award":["CN16-161"],"award-info":[{"award-number":["CN16-161"]}]},{"name":"Nature Science Foundation of China","award":["61604095"],"award-info":[{"award-number":["61604095"]}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Des. Autom. Electron. Syst."],"published-print":{"date-parts":[[2018,7,31]]},"abstract":"<jats:p>In this article, we propose a novel approach to detect the occupancy behavior of a building through the temperature and\/or possible heat source information. The new method can be used for energy reduction and security monitoring for emerging smart buildings. Our work is based on a building simulation program, EnergyPlus, from the Department of Energy. EnergyPlus can model various time-series inputs to a building such as ambient temperature; heating, ventilation, and air-conditioning (HVAC) inputs; power consumption of electronic equipment; lighting; and number of occupants in a room, sampled each hour, and produce resulting temperature traces of zones (rooms). Two machine-learning-based approaches for detecting human occupancy of a smart building are applied herein, namely support vector regression (SVR) and recurrent neural network (RNN). Experimental results with SVR show that the four-feature model provides accurate detection rates, giving a 0.638 average error and 5.32% error rate, and the five-feature model delivers a 0.317 average error and 2.64% error rate. This indicates that SVR is a viable option for occupancy detection. In the RNN method, Elman\u2019s RNN can estimate occupancy information of each room of a building with high accuracy. It has local feedback in each layer and, for a five-zone building, it is very accurate for occupancy behavior estimation. The error level, in terms of number of people, can be as low as 0.0056 on average and 0.288 at maximum, considering ambient, room temperatures, and HVAC powers as detectable information. Without knowing HVAC powers, the estimation error can still be 0.044 on average, and only 0.71% estimated points have errors greater than 0.5. Our article further shows that both methods deliver similar accuracy in the occupancy detection. But the SVR model is more stable for adding or removing features of the system, while the RNN method can deliver more accuracy when the features used in the model do not change a lot.<\/jats:p>","DOI":"10.1145\/3200904","type":"journal-article","created":{"date-parts":[[2018,6,28]],"date-time":"2018-06-28T16:38:11Z","timestamp":1530203891000},"page":"1-21","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":35,"title":["Thermal-Sensor-Based Occupancy Detection for Smart Buildings Using Machine-Learning Methods"],"prefix":"10.1145","volume":"23","author":[{"given":"Hengyang","family":"Zhao","sequence":"first","affiliation":[{"name":"University of California, Riverside, CA, USA"}]},{"given":"Qi","family":"Hua","sequence":"additional","affiliation":[{"name":"Shanghai Jiao Tong University, Shanghai, China"}]},{"given":"Hai-Bao","family":"Chen","sequence":"additional","affiliation":[{"name":"Shanghai Jiao Tong University, Shanghai, China"}]},{"given":"Yaoyao","family":"Ye","sequence":"additional","affiliation":[{"name":"Shanghai Jiao Tong University, Shanghai, China"}]},{"given":"Hai","family":"Wang","sequence":"additional","affiliation":[{"name":"University of Electronic Science and Technology of China, Chengdu, China"}]},{"given":"Sheldon X.-D.","family":"Tan","sequence":"additional","affiliation":[{"name":"University of California, Riverside, CA, USA"}]},{"given":"Esteban","family":"Tlelo-Cuautle","sequence":"additional","affiliation":[{"name":"INAOE, Mexico, Puebla, Mexico"}]}],"member":"320","published-online":{"date-parts":[[2018,6,28]]},"reference":[{"key":"e_1_2_1_1_1","volume-title":"Proceedings of the 6th USENIX Symposium on Networked Systems Design and Implementation (NSDI\u201909)","author":"Agarwal Yuvraj","year":"2009"},{"key":"e_1_2_1_2_1","volume-title":"Proceedings of the 2010 USENIX Annual Technical Conference (USENIXATC\u201910)","author":"Agarwal Yuvraj","year":"2010"},{"key":"e_1_2_1_3_1","volume-title":"Filed","author":"Bias Larry Stephen","year":"1999"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-7788(00)00114-6"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1145\/1810279.1810293"},{"key":"e_1_2_1_6_1","unstructured":"Department of Energy. 2016. Annual Energy Review. Retrieved from https:\/\/www.eia.gov\/totalenergy\/data\/annual\/index.php#consumption.  Department of Energy. 2016. Annual Energy Review. Retrieved from https:\/\/www.eia.gov\/totalenergy\/data\/annual\/index.php#consumption."},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2005.12.001"},{"key":"e_1_2_1_8_1","volume-title":"Building Simulation","author":"Dong Bing"},{"key":"e_1_2_1_9_1","volume-title":"Proceedings of the 2013 7th IEEE International Conference on Digital Ecosystems and Technologies (DEST\u201913)","author":"Ekwevugbe T."},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1207\/s15516709cog1402_1"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1145\/1810279.1810284"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1145\/1810279.1810294"},{"key":"e_1_2_1_13_1","volume-title":"Neural Networks: A Comprehensive Foundation","author":"Haykin Simon","year":"2007"},{"key":"e_1_2_1_14_1","volume-title":"Scientific Computing: An Introductory Survey","author":"Heath Michael T.","year":"2002"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.5555\/140639.140643"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2011.2167353"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0925-2312(01)00700-7"},{"key":"e_1_2_1_19_1","first-page":"1452","article-title":"Occupancy detection through an extensive environmental sensor network in an open-plan office building","volume":"145","author":"Lam Khee Poh","year":"2009","journal-title":"IBPSA Building Simul."},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1145\/1869983.1870005"},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.1145\/1869983.1870005"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2012.2183649"},{"key":"e_1_2_1_23_1","volume-title":"Proceedings of the 2014 International Green Computing Conference (IGCC\u201914)","author":"Majumdar Abhinandan"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1177\/1477153509339703"},{"key":"e_1_2_1_25_1","volume-title":"Proceedings of the 9th International Conference on Neural Information Processing Systems (NIPS\u201996)","author":"Mozer Michael C.","year":"1996"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2012.09.005"},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/5.537107"},{"key":"e_1_2_1_28_1","volume-title":"Proceedings of the IEEE International Conference on Neural Networks. 586--591","author":"Riedmiller M."},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neunet.2014.09.003"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1145\/2030112.2030151"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2012.2215060"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1109\/5.58337"},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1080\/19401493.2010.518631"},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1109\/TITS.2004.837813"},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2015.12.019"}],"container-title":["ACM Transactions on Design Automation of Electronic Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3200904","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3200904","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T02:26:30Z","timestamp":1750213590000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3200904"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,28]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,7,31]]}},"alternative-id":["10.1145\/3200904"],"URL":"https:\/\/doi.org\/10.1145\/3200904","relation":{},"ISSN":["1084-4309","1557-7309"],"issn-type":[{"value":"1084-4309","type":"print"},{"value":"1557-7309","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,28]]},"assertion":[{"value":"2017-10-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-03-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-06-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}