{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T04:43:11Z","timestamp":1792644191803,"version":"4.5.0"},"reference-count":51,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2018,9,18]],"date-time":"2018-09-18T00:00:00Z","timestamp":1537228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2018,9,18]]},"abstract":"<jats:p>Normal circadian rhythm mediates blood pressure during sleep, decreasing in value in healthy subjects. Current methods to monitor nocturnal blood pressure use an active blood pressure cuff that repeatedly auto-inflates while the subject sleeps. Since these inflations happen in intervals of thirty minutes to one hour, they cause considerable sleep disturbances that lead to false measurements and impact the person's quality of sleep. These blood pressure samples are also just spot checks and rarely exceed 10-15 values per night.<\/jats:p>\n          <jats:p>We present Naptics, a wearable device woven into shorts. Naptics passively monitors the wearer's blood pressure throughout the night---continuously and unobtrusively---without disturbing the user during sleep. Naptics detects the micro-vibrations of the wearer's body that stem from the heartbeat and senses the optical reflections from the pulse wave as it propagates down the wearer's leg. From the timing between these two events, Naptics computes the pulse transit time, which correlates strongly with the user's blood pressure.<\/jats:p>\n          <jats:p>Naptics' key novelty is its unobtrusive approach in tracking blood pressure during the night. Our controlled evaluation of six subjects showed a high correlation (r = 0.89) between Naptics' calibrated mean arterial pressure and cuff-based blood pressure. Our in-the-wild evaluation validates Naptics in tracking five participants' blood pressure patterns throughout four nights and compares them to before and after cuff measurements. In a majority of the nights, Naptics correctly followed the trend of the cuff measurements while providing insights into the behavior and the patterns of participants' nocturnal blood pressure. Participants reported high sleep quality in sleep diaries after each night, validating Naptics as a convenient monitoring apparatus.<\/jats:p>","DOI":"10.1145\/3264906","type":"journal-article","created":{"date-parts":[[2018,9,19]],"date-time":"2018-09-19T11:58:41Z","timestamp":1537358321000},"page":"1-22","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":25,"title":["Naptics"],"prefix":"10.1145","volume":"2","author":[{"given":"Andrew","family":"Carek","sequence":"first","affiliation":[{"name":"Microsoft Research, Redmond 8 Georgia Institute of Technology, Atlanta, GA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Holz","sequence":"additional","affiliation":[{"name":"Microsoft Research, Redmond, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2018,9,18]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.110.160911"},{"key":"e_1_2_1_2_1","doi-asserted-by":"crossref","unstructured":"Rajiv Agarwal and Robert Light. 2009. The Effect of Measuring Ambulatory Blood Pressure on Nighttime Sleep and Daytime Activity-Implications for Dipping. 5 (12 2009) 281--5.  Rajiv Agarwal and Robert Light. 2009. The Effect of Measuring Ambulatory Blood Pressure on Nighttime Sleep and Daytime Activity-Implications for Dipping. 5 (12 2009) 281--5.","DOI":"10.2215\/CJN.07011009"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/28\/3\/R01"},{"key":"e_1_2_1_4_1","doi-asserted-by":"crossref","unstructured":"A. Babchenko E. Davidson D. Adler Y. Ginosar V. Kurz and M. Nitzan. 2000. Increase in pulse transit time to the foot after epidural anaesthesia treatment. Medical and Biological Engineering and Computing 38 6 (01 Nov 2000) 674--679.  A. Babchenko E. Davidson D. Adler Y. Ginosar V. Kurz and M. Nitzan. 2000. Increase in pulse transit time to the foot after epidural anaesthesia treatment. Medical and Biological Engineering and Computing 38 6 (01 Nov 2000) 674--679.","DOI":"10.1007\/BF02344874"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.107.105510"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.299.24.2857"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.107.087262"},{"key":"e_1_2_1_8_1","doi-asserted-by":"crossref","unstructured":"Jos\u00e9 Boggia Yan Li Lutgarde Thijs Tine W Hansen Masahiro Kikuya Kristina Bj\u00f6rklund-Bodeg\u00e5rd Tom Richart Takayoshi Ohkubo Tatiana Kuznetsova Christian Torp-Pedersen Lars Lind Hans Ibsen Yutaka Imai Jiguang Wang Edgardo Sandoya Eoin O'Brien and Jan A Staessen. 2007. Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study. The Lancet 370 9594 (2007) 1219 - 1229.  Jos\u00e9 Boggia Yan Li Lutgarde Thijs Tine W Hansen Masahiro Kikuya Kristina Bj\u00f6rklund-Bodeg\u00e5rd Tom Richart Takayoshi Ohkubo Tatiana Kuznetsova Christian Torp-Pedersen Lars Lind Hans Ibsen Yutaka Imai Jiguang Wang Edgardo Sandoya Eoin O'Brien and Jan A Staessen. 2007. Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study. The Lancet 370 9594 (2007) 1219 - 1229.","DOI":"10.1016\/S0140-6736(07)61538-4"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1098\/rspb.1922.0022"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1145\/3130905"},{"key":"e_1_2_1_11_1","doi-asserted-by":"crossref","unstructured":"Mary A Carskadon William C Dement etal 2005. Normal human sleep: an overview. Principles and practice of sleep medicine 4 (2005) 13--23.  Mary A Carskadon William C Dement et al. 2005. Normal human sleep: an overview. Principles and practice of sleep medicine 4 (2005) 13--23.","DOI":"10.1016\/B0-72-160797-7\/50009-4"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/26\/4\/007"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/30\/11\/002"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/1.2.117"},{"key":"e_1_2_1_15_1","doi-asserted-by":"crossref","unstructured":"RJO Davies NE Jenkins and JR Stradling. 1994. Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308 6932 (1994) 820--823.  RJO Davies NE Jenkins and JR Stradling. 1994. Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308 6932 (1994) 820--823.","DOI":"10.1136\/bmj.308.6932.820"},{"key":"e_1_2_1_16_1","doi-asserted-by":"crossref","unstructured":"R J O Davies NE Jenkins and J R Stradling. 1994. Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308 6932 (1994) 820--823.  R J O Davies NE Jenkins and J R Stradling. 1994. Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308 6932 (1994) 820--823.","DOI":"10.1136\/bmj.308.6932.820"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1145\/3053330"},{"key":"e_1_2_1_18_1","doi-asserted-by":"crossref","unstructured":"Xiaorong Ding Bryan P. Yan Yuan-Ting Zhang Jing Liu Ni Zhao and Hon Tsang. 2017. Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation. 7 (12 2017).  Xiaorong Ding Bryan P. Yan Yuan-Ting Zhang Jing Liu Ni Zhao and Hon Tsang. 2017. Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation. 7 (12 2017).","DOI":"10.1038\/s41598-017-11507-3"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.85.1.6"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-013-0854-y"},{"key":"e_1_2_1_21_1","doi-asserted-by":"crossref","unstructured":"Mingwu Gao N Bari Olivier and Ramakrishna Mukkamala. 2016. Comparison of non-invasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference. Physiological reports 4 10 (2016).  Mingwu Gao N Bari Olivier and Ramakrishna Mukkamala. 2016. Comparison of non-invasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference. Physiological reports 4 10 (2016).","DOI":"10.14814\/phy2.12768"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn013"},{"key":"e_1_2_1_23_1","doi-asserted-by":"crossref","unstructured":"E Heude P Bourgin P Feigel and P Escourrou. 1996. Ambulatory monitoring of blood pressure disturbs sleep and raises systolic pressure at night in patients suspected of suffering from sleep-disordered breathing. Clinical science 91 1 (1996) 45--50.  E Heude P Bourgin P Feigel and P Escourrou. 1996. Ambulatory monitoring of blood pressure disturbs sleep and raises systolic pressure at night in patients suspected of suffering from sleep-disordered breathing. Clinical science 91 1 (1996) 45--50.","DOI":"10.1042\/cs0910045"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1145\/3132024"},{"key":"e_1_2_1_25_1","volume-title":"Beating Insomnia: How to Get a Good Night's Sleep. Gill 8 Macmillan Ltd.","author":"Idzikowski Christopher","year":"2003"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.21.1.65"},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2014.2361732"},{"key":"e_1_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.282.6.539"},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1080\/10641960802251974"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2015.2440291"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2010.2044797"},{"key":"e_1_2_1_32_1","doi-asserted-by":"crossref","unstructured":"Stephanie L.-O. Martin Andrew M. Carek Chang-Sei Kim Hazar Ashouri Omer Inan Jin-Oh Hahn and Ramakrishna Mukkamala. 2016. Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time. 6 (12 2016) 39273.  Stephanie L.-O. Martin Andrew M. Carek Chang-Sei Kim Hazar Ashouri Omer Inan Jin-Oh Hahn and Ramakrishna Mukkamala. 2016. Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time. 6 (12 2016) 39273.","DOI":"10.1038\/srep39273"},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.111.00217"},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.3.5979.346"},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.7.004313"},{"key":"e_1_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2869.1994.tb00114.x"},{"key":"e_1_2_1_37_1","doi-asserted-by":"crossref","unstructured":"Ramakrishna Mukkamala Jin-Oh Hahn Omer T Inan Lalit Mestha Chang-Sei Kim Hakan Toreyin and Snurvi Kyal. 2015. Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice. 62 (06 2015).  Ramakrishna Mukkamala Jin-Oh Hahn Omer T Inan Lalit Mestha Chang-Sei Kim Hakan Toreyin and Snurvi Kyal. 2015. Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice. 62 (06 2015).","DOI":"10.1109\/TBME.2015.2441951"},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/23\/1\/308"},{"key":"e_1_2_1_39_1","doi-asserted-by":"crossref","unstructured":"Eoin O'Brien Roland Asmar Lawrence Beilin Yutaka Imai Giuseppe Mancia Thomas Mengden Martin Myers Paul Padfield Paolo Palatini Gianfranco Parati Thomas Pickering Josep Redon Jan Staessen George Stergiou and Paolo Verdecchia. 2005. Practice Guidelines of the European Society of Hypertension for Clinic Ambulatory and Self Blood Pressure Measurement. 23 (05 2005) 697--701.  Eoin O'Brien Roland Asmar Lawrence Beilin Yutaka Imai Giuseppe Mancia Thomas Mengden Martin Myers Paul Padfield Paolo Palatini Gianfranco Parati Thomas Pickering Josep Redon Jan Staessen George Stergiou and Paolo Verdecchia. 2005. Practice Guidelines of the European Society of Hypertension for Clinic Ambulatory and Self Blood Pressure Measurement. 23 (05 2005) 697--701.","DOI":"10.1097\/01.hjh.0000163132.84890.c4"},{"key":"e_1_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.26.5.835"},{"key":"e_1_2_1_41_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.113.02148"},{"key":"e_1_2_1_42_1","volume-title":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 3784--3788","author":"Paalasmaa J."},{"key":"e_1_2_1_43_1","doi-asserted-by":"crossref","unstructured":"Gianfranco Parati Juan Ochoa Carolina Lombardi and Grzegorz Bilo. 2013. Assessment and management of blood-pressure variability. 10 (03 2013) 143--55.  Gianfranco Parati Juan Ochoa Carolina Lombardi and Grzegorz Bilo. 2013. Assessment and management of blood-pressure variability. 10 (03 2013) 143--55.","DOI":"10.1038\/nrcardio.2013.1"},{"key":"e_1_2_1_44_1","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00657.2005"},{"key":"e_1_2_1_45_1","volume-title":"2005 IEEE Engineering in Medicine and Biology 27th Annual Conference. 5877--5880","author":"Poon C. C. Y."},{"key":"e_1_2_1_46_1","volume-title":"Retrieved","author":"Respironics Philips","year":"2014"},{"key":"e_1_2_1_47_1","doi-asserted-by":"crossref","unstructured":"Eliot S Katz Janita Lutz Cheryl Black and Carole L Marcus. 2003. Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered Breathing. 53 (04 2003) 580--8.  Eliot S Katz Janita Lutz Cheryl Black and Carole L Marcus. 2003. Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered Breathing. 53 (04 2003) 580--8.","DOI":"10.1203\/01.PDR.0000057206.14698.47"},{"key":"e_1_2_1_48_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000160923.04524.5B"},{"key":"e_1_2_1_49_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2016.2643780"},{"key":"e_1_2_1_50_1","first-page":"1","article-title":"Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison","volume":"99","author":"Yang C.","year":"2017","journal-title":"IEEE Journal of Biomedical and Health Informatics PP"},{"key":"e_1_2_1_51_1","volume-title":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 6103--6106","author":"Zheng Y.","year":"2013"}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3264906","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3264906","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T02:07:59Z","timestamp":1750212479000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3264906"}},"subtitle":["Convenient and Continuous Blood Pressure Monitoring during Sleep"],"short-title":[],"issued":{"date-parts":[[2018,9,18]]},"references-count":51,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,9,18]]}},"alternative-id":["10.1145\/3264906"],"URL":"https:\/\/doi.org\/10.1145\/3264906","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,18]]},"assertion":[{"value":"2017-11-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-09-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-09-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}