{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:30:36Z","timestamp":1750221036538,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":9,"publisher":"ACM","license":[{"start":{"date-parts":[[2018,10,24]],"date-time":"2018-10-24T00:00:00Z","timestamp":1540339200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"name":"FDCT Macau","award":["FDCT\/126\/2014\/A3"],"award-info":[{"award-number":["FDCT\/126\/2014\/A3"]}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,10,24]]},"DOI":"10.1145\/3289430.3289462","type":"proceedings-article","created":{"date-parts":[[2018,12,4]],"date-time":"2018-12-04T15:29:22Z","timestamp":1543937362000},"page":"218-221","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Counting Passengers in Public Buses by Sensing Carbon Dioxide Concentration"],"prefix":"10.1145","author":[{"given":"Tengyue","family":"Li","sequence":"first","affiliation":[{"name":"Department of Computer and Information Science, University of Macau, Taipa, Macau SAR"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Fong","sequence":"additional","affiliation":[{"name":"Department of Computer and Information Science, University of Macau, Taipa, Macau SAR"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2018,10,24]]},"reference":[{"key":"e_1_3_2_1_1_1","volume-title":"Retrieved","author":"Soh M. K.","year":"2016","unstructured":"Jiang, C., Masood, M. K. , Soh , Y. C. , & Li , H. (n.d.). Indoor occupancy estimation from carbon dioxide concentration . Retrieved July 20, 2016 . Jiang, C., Masood, M. K., Soh, Y. C., & Li, H. (n.d.). Indoor occupancy estimation from carbon dioxide concentration. Retrieved July 20, 2016."},{"key":"e_1_3_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2014.01.090"},{"key":"e_1_3_2_1_3_1","volume-title":"Surveys","volume":"5","author":"Teixeira T.","year":"2010","unstructured":"T. Teixeira , G. Dublon , and A. Savvides , \" A survey of human-sensing: Methods for detecting presence, count, location, track, and identity,\"ACM Comput . Surveys , vol. 5 , 2010 . T. Teixeira, G. Dublon, and A. Savvides, \"A survey of human-sensing: Methods for detecting presence, count, location, track, and identity,\"ACM Comput. Surveys, vol. 5, 2010."},{"key":"e_1_3_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1109\/JSAC.2015.2430272"},{"key":"e_1_3_2_1_5_1","unstructured":"CO2 sensor MH-Z16 {Online}. Available: https:\/\/www.mouser.com\/ds\/2\/744\/Seeed_101020067-1217507.pdf  CO2 sensor MH-Z16 {Online}. Available: https:\/\/www.mouser.com\/ds\/2\/744\/Seeed_101020067-1217507.pdf"},{"key":"e_1_3_2_1_6_1","article-title":"Occupancy inference using pyroelectric infrared sensors through hidden Markov models","author":"Liu P.","unstructured":"P. Liu , S. K. Nguang , and A. Partridge , \" Occupancy inference using pyroelectric infrared sensors through hidden Markov models ,\" IEEE Sensors J. P. Liu, S. K. Nguang, and A. Partridge, \"Occupancy inference using pyroelectric infrared sensors through hidden Markov models,\" IEEE Sensors J.","journal-title":"IEEE Sensors J."},{"key":"e_1_3_2_1_7_1","volume-title":"Conf. Digital Ecosys. Tech.","author":"Ekwevugbe T.","year":"2013","unstructured":"T. Ekwevugbe , N. Brown , V. Pakka , and D. Fan , \" Real-time building occupancy sensing using neural-network based sensor network,\" IEEE Int . Conf. Digital Ecosys. Tech. , 2013 T. Ekwevugbe, N. Brown, V. Pakka, and D. Fan, \"Real-time building occupancy sensing using neural-network based sensor network,\" IEEE Int. Conf. Digital Ecosys. Tech., 2013"},{"key":"e_1_3_2_1_8_1","unstructured":"G. Ansanay-Alex \"Estimating occupancy using indoor carbon dioxide concentrations only in an office building: a method and qualitative assessment \" 11th REHVA World Congr. Energy Eff. Smart Healthy Build. 2013  G. Ansanay-Alex \"Estimating occupancy using indoor carbon dioxide concentrations only in an office building: a method and qualitative assessment \" 11th REHVA World Congr. Energy Eff. Smart Healthy Build. 2013"},{"key":"e_1_3_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neucom.2005.12.126"}],"event":{"name":"BDIOT 2018: 2018 2nd International Conference on Big Data and Internet of Things","sponsor":["Deakin University"],"location":"Beijing China","acronym":"BDIOT 2018"},"container-title":["Proceedings of the 2018 2nd International Conference on Big Data and Internet of Things"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3289430.3289462","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3289430.3289462","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T00:43:40Z","timestamp":1750207420000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3289430.3289462"}},"subtitle":["System Design and Implementation"],"short-title":[],"issued":{"date-parts":[[2018,10,24]]},"references-count":9,"alternative-id":["10.1145\/3289430.3289462","10.1145\/3289430"],"URL":"https:\/\/doi.org\/10.1145\/3289430.3289462","relation":{},"subject":[],"published":{"date-parts":[[2018,10,24]]},"assertion":[{"value":"2018-10-24","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}