{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T06:49:28Z","timestamp":1782370168049,"version":"3.54.5"},"reference-count":4,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T00:00:00Z","timestamp":1547683200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["SIGMETRICS Perform. Eval. Rev."],"published-print":{"date-parts":[[2019,1,18]]},"abstract":"<jats:p>We study cyber attacks on power grids that affect both the physical infrastructure and the data at the control center? which therefore are cyber-physical in nature. In particular, we assume that an adversary attacks an area by: (i) remotely disconnecting some lines within the attacked area, and (ii) modifying the information received from the attacked area to mask the line failures and hide the attacked area from the control center. For the latter, we consider two types of attacks: (i) data distortion: which distorts the data by adding powerful noise to the actual data, and (ii) data replay: which replays a locally consistent old data instead of the actual data. We use the DC power flow model and prove that the problem of finding the set of line failures given the phase angles of the nodes outside of the attacked area is strongly NP-hard, even when the attacked area is known. However, we introduce the polynomial time REcurrent Attack Containment and deTection (REACT) Algorithm to approximately detect the attacked area and line failures after a cyber-physical attack.<\/jats:p>","DOI":"10.1145\/3305218.3305238","type":"journal-article","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T17:15:15Z","timestamp":1547745315000},"page":"50-51","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["REACT to Cyber-Physical Attacks on Power grids (Extended Abstract)"],"prefix":"10.1145","volume":"46","author":[{"given":"Saleh","family":"Soltan","sequence":"first","affiliation":[{"name":"Princeton University, Princeton, NJ, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihalis","family":"Yannakakis","sequence":"additional","affiliation":[{"name":"Columbia University, New York, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gil","family":"Zussman","sequence":"additional","affiliation":[{"name":"Columbia University, New York, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2019,1,17]]},"reference":[{"key":"e_1_2_1_1_1","volume-title":"http:\/\/www.nerc.com\/pa\/CI\/ESISAC\/Documents\/ E-ISAC_SANS_Ukraine_DUC_18Mar2016.pdf. Accessed","author":"NERC.","year":"2018","unstructured":"NERC. Analysis of the cyber attack on the Ukrainian power grid, 2016. http:\/\/www.nerc.com\/pa\/CI\/ESISAC\/Documents\/ E-ISAC_SANS_Ukraine_DUC_18Mar2016.pdf. Accessed : Jan. 2018 . NERC. Analysis of the cyber attack on the Ukrainian power grid, 2016. http:\/\/www.nerc.com\/pa\/CI\/ESISAC\/Documents\/ E-ISAC_SANS_Ukraine_DUC_18Mar2016.pdf. Accessed: Jan. 2018."},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1145\/2745844.2745846"},{"key":"e_1_2_1_3_1","volume":"201","author":"Soltan S.","unstructured":"S. Soltan , M. Yannakakis , and G. Zussman . REACT to cyber attacks on power grids. to appear in IEEE Trans. Netw. Sci. Eng. , 201 8. S. Soltan, M. Yannakakis, and G. Zussman. REACT to cyber attacks on power grids. to appear in IEEE Trans. Netw. Sci. Eng., 2018.","journal-title":"IEEE Trans. Netw. Sci. Eng."},{"key":"e_1_2_1_4_1","volume":"201","author":"Soltan S.","unstructured":"S. Soltan and G. Zussman . EXPOSE the line failures following a cyber-physical attack on the power grid. to appear in IEEE Trans. Control Netw. Syst. , 201 8. S. Soltan and G. Zussman. EXPOSE the line failures following a cyber-physical attack on the power grid. to appear in IEEE Trans. Control Netw. Syst., 2018.","journal-title":"IEEE Trans. Control Netw. Syst."}],"container-title":["ACM SIGMETRICS Performance Evaluation Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3305218.3305238","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3305218.3305238","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T00:58:09Z","timestamp":1750208289000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3305218.3305238"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,17]]},"references-count":4,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,1,18]]}},"alternative-id":["10.1145\/3305218.3305238"],"URL":"https:\/\/doi.org\/10.1145\/3305218.3305238","relation":{},"ISSN":["0163-5999"],"issn-type":[{"value":"0163-5999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1,17]]},"assertion":[{"value":"2019-01-17","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}