{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T07:11:40Z","timestamp":1770966700480,"version":"3.50.1"},"reference-count":41,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2019,7,31]],"date-time":"2019-07-31T00:00:00Z","timestamp":1564531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Appl. Percept."],"published-print":{"date-parts":[[2019,7,31]]},"abstract":"<jats:p>Head-mounted displays cause discomfort. This is commonly attributed to conflicting depth cues, most prominently between vergence, which is consistent with object depth, and accommodation, which is adjusted to the near eye displays.<\/jats:p>\n          <jats:p>It is possible to adjust the camera parameters, specifically interocular distance and vergence angles, for rendering the virtual environment to minimize this conflict. This requires dynamic adjustment of the parameters based on object depth. In an experiment based on a visual search task, we evaluate how dynamic adjustment affects visual comfort compared to fixed camera parameters. We collect objective as well as subjective data. Results show that dynamic adjustment decreases common objective measures of visual comfort such as pupil diameter and blink rate by a statistically significant margin. The subjective evaluation of categories such as fatigue or eye irritation shows a similar trend but was inconclusive. This suggests that rendering with fixed camera parameters is the better choice for head-mounted displays, at least in scenarios similar to the ones used here.<\/jats:p>","DOI":"10.1145\/3353902","type":"journal-article","created":{"date-parts":[[2019,9,6]],"date-time":"2019-09-06T13:04:41Z","timestamp":1567775081000},"page":"1-16","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Keep It Simple"],"prefix":"10.1145","volume":"16","author":[{"given":"Jochen","family":"Jacobs","sequence":"first","affiliation":[{"name":"TU Berlin, Marchstrasse, Berlin, Germany"}]},{"given":"Xi","family":"Wang","sequence":"additional","affiliation":[{"name":"TU Berlin, Marchstrasse, Berlin, Germany"}]},{"given":"Marc","family":"Alexa","sequence":"additional","affiliation":[{"name":"TU Berlin, Marchstrasse, Berlin, Germany"}]}],"member":"320","published-online":{"date-parts":[[2019,9,6]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"crossref","unstructured":"David A. Atchison George Smith and George Smith. 2000. Optics of the human eye. Butterworth-Heinemann Oxford.  David A. Atchison George Smith and George Smith. 2000. Optics of the human eye. Butterworth-Heinemann Oxford.","DOI":"10.1016\/B978-0-7506-3775-6.50024-9"},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2010.544442"},{"key":"e_1_2_1_3_1","volume-title":"Dodgson (Eds.)","volume":"7863","author":"Chen Wei","year":"2011","unstructured":"Wei Chen , J\u00e9r\u00f4me Fournier , Marcus Barkowsky , and Patrick Le Callet . 2011 . New stereoscopic video shooting rule based on stereoscopic distortion parameters and comfortable viewing zone. In IS&T\/SPIE Electronic Imaging, Andrew J. Woods, Nicolas S. Holliman, and Neil A . Dodgson (Eds.) , Vol. 7863 . 78631O. Wei Chen, J\u00e9r\u00f4me Fournier, Marcus Barkowsky, and Patrick Le Callet. 2011. New stereoscopic video shooting rule based on stereoscopic distortion parameters and comfortable viewing zone. In IS&T\/SPIE Electronic Imaging, Andrew J. Woods, Nicolas S. Holliman, and Neil A. Dodgson (Eds.), Vol. 7863. 78631O."},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1145\/2628257.2628259"},{"key":"e_1_2_1_5_1","volume-title":"Dimitra Vasilarou, and Martin Kraus.","author":"Fisker Martin","year":"2013","unstructured":"Martin Fisker , Kristoffer Gram , Kasper Kronborg Thomsen , Dimitra Vasilarou, and Martin Kraus. 2013 . Automatic convergence adjustment for stereoscopy using eye tracking. Eurographics . Martin Fisker, Kristoffer Gram, Kasper Kronborg Thomsen, Dimitra Vasilarou, and Martin Kraus. 2013. Automatic convergence adjustment for stereoscopy using eye tracking. Eurographics."},{"key":"e_1_2_1_6_1","volume-title":"Talathi","author":"Garbin Stephan J.","year":"2019","unstructured":"Stephan J. Garbin , Yiru Shen , Immo Schuetz , Robert Cavin , Gregory Hughes , and Sachin S . Talathi . 2019 . OpenEDS: Open eye dataset. CoRR abs\/1905.03702 (2019). arXiv:1905.03702 http:\/\/arxiv.org\/abs\/1905.03702 Stephan J. Garbin, Yiru Shen, Immo Schuetz, Robert Cavin, Gregory Hughes, and Sachin S. Talathi. 2019. OpenEDS: Open eye dataset. CoRR abs\/1905.03702 (2019). arXiv:1905.03702 http:\/\/arxiv.org\/abs\/1905.03702"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1167\/8.3.33"},{"key":"e_1_2_1_8_1","volume-title":"Eye Tracking: A Comprehensive Guide to Methods and Measures","author":"Holmqvist Kenneth","year":"2011","unstructured":"Kenneth Holmqvist , Marcus Nystr\u00f6m , Richard Andersson , Richard Dewhurst , Halszka Jarodzka , and Joost Van de Weijer . 2011 . Eye Tracking: A Comprehensive Guide to Methods and Measures . Oxford University Press , Oxford . Kenneth Holmqvist, Marcus Nystr\u00f6m, Richard Andersson, Richard Dewhurst, Halszka Jarodzka, and Joost Van de Weijer. 2011. Eye Tracking: A Comprehensive Guide to Methods and Measures. Oxford University Press, Oxford."},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.2008206"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1364\/OE.24.011808"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1145\/2897824.2925866"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICDSP.2011.6004999"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1145\/2858036.2858140"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.displa.2004.07.004"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1145\/3072959.3073622"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/VR.2016.7504694"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1145\/1778765.1778812"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1080\/00140139.2010.489968"},{"key":"e_1_2_1_19_1","volume-title":"Lockhart and Wen Shi","author":"Thurmon","year":"2010","unstructured":"Thurmon E. Lockhart and Wen Shi . 2010 b. Effects of age on dynamic accommodation. Ergonomics 53, 7 (10 2010), 892--903. Thurmon E. Lockhart and Wen Shi. 2010b. Effects of age on dynamic accommodation. Ergonomics 53, 7 (10 2010), 892--903."},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00081-9"},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.1145\/2503144"},{"key":"e_1_2_1_22_1","volume-title":"3D Movie Making: Stereoscopic Digital Cinema from Script to Screen","author":"Mendiburu Bernard","unstructured":"Bernard Mendiburu . 2012. 3D Movie Making: Stereoscopic Digital Cinema from Script to Screen . Routledge . Bernard Mendiburu. 2012. 3D Movie Making: Stereoscopic Digital Cinema from Script to Screen. Routledge."},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1076\/0271-3683(200007)2111-ZFT535"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1076\/0271-3683(200007)2111-ZFT535"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1145\/2070781.2024223"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1617251114"},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1889\/1.1831799"},{"key":"e_1_2_1_28_1","volume-title":"Saccades reduce latency and increase velocity of ocular accommodation. Vis. Res. 39, 22 (10","author":"Schor Clifton M.","year":"1999","unstructured":"Clifton M. Schor , Lori A. Lott , David Pope , and Andrew D Graham . 1999. Saccades reduce latency and increase velocity of ocular accommodation. Vis. Res. 39, 22 (10 1999 ), 3769--3795. Clifton M. Schor, Lori A. Lott, David Pope, and Andrew D Graham. 1999. Saccades reduce latency and increase velocity of ocular accommodation. Vis. Res. 39, 22 (10 1999), 3769--3795."},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1515\/cdbme-2017-0121"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1145\/2159616.2159620"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1167\/11.8.11"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1889\/1.1987395"},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.474093"},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBC.2011.2125070"},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.image.2016.08.002"},{"key":"e_1_2_1_36_1","volume-title":"Accuracy of monocular gaze tracking on 3D geometry","author":"Wang Xi","unstructured":"Xi Wang , David Lindlbauer , Christian Lessig , and Marc Alexa . 2017. Accuracy of monocular gaze tracking on 3D geometry . In Eye Tracking and Visualization, Michael Burch, Lewis Chuang, Brian Fisher, Albrecht Schmidt, and Daniel Weiskopf (Eds.). Springer International Publishing , Cham , 169--184. Xi Wang, David Lindlbauer, Christian Lessig, and Marc Alexa. 2017. Accuracy of monocular gaze tracking on 3D geometry. In Eye Tracking and Visualization, Michael Burch, Lewis Chuang, Brian Fisher, Albrecht Schmidt, and Daniel Weiskopf (Eds.). Springer International Publishing, Cham, 169--184."},{"key":"e_1_2_1_37_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.157041"},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICHI.2017.74"},{"key":"e_1_2_1_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2018.06.005"},{"key":"e_1_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1145\/1028174.971421"},{"key":"e_1_2_1_41_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICMULT.2010.5630864"}],"container-title":["ACM Transactions on Applied Perception"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3353902","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3353902","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T17:49:38Z","timestamp":1750268978000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3353902"}},"subtitle":["Depth-based Dynamic Adjustment of Rendering for Head-mounted Displays Decreases Visual Comfort"],"short-title":[],"issued":{"date-parts":[[2019,7,31]]},"references-count":41,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,7,31]]}},"alternative-id":["10.1145\/3353902"],"URL":"https:\/\/doi.org\/10.1145\/3353902","relation":{},"ISSN":["1544-3558","1544-3965"],"issn-type":[{"value":"1544-3558","type":"print"},{"value":"1544-3965","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,31]]},"assertion":[{"value":"2019-07-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-07-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-09-06","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}