{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:29:48Z","timestamp":1792787388958,"version":"4.5.0"},"publisher-location":"New York, NY, USA","reference-count":80,"publisher":"ACM","license":[{"start":{"date-parts":[[2020,9,18]],"date-time":"2020-09-18T00:00:00Z","timestamp":1600387200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"name":"National Science Foundation","award":["CNS-1812399, CNS-1812407 and CNS-2029520"],"award-info":[{"award-number":["CNS-1812399, CNS-1812407 and CNS-2029520"]}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,9,21]]},"DOI":"10.1145\/3372224.3419209","type":"proceedings-article","created":{"date-parts":[[2020,9,18]],"date-time":"2020-09-18T22:16:16Z","timestamp":1600467376000},"page":"1-14","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":98,"title":["SpiroSonic"],"prefix":"10.1145","author":[{"given":"Xingzhe","family":"Song","sequence":"first","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyuan","family":"Yang","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ge","family":"Yang","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruirong","family":"Chen","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erick","family":"Forno","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Chen","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Gao","sequence":"additional","affiliation":[{"name":"University of Pittsburgh"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2020,9,18]]},"reference":[{"key":"e_1_3_2_1_1_1","unstructured":"EasyOne Air. https:\/\/www.nddmed.com\/en-us\/product\/easyone-air.html.  EasyOne Air. https:\/\/www.nddmed.com\/en-us\/product\/easyone-air.html."},{"key":"e_1_3_2_1_2_1","volume-title":"Zephyr: Ubiquitous accurate multi-sensor fusion-based respiratory rate estimation using smartphones","author":"Aly Heba","year":"2016","unstructured":"Heba Aly and Moustafa Youssef . 2016 . Zephyr: Ubiquitous accurate multi-sensor fusion-based respiratory rate estimation using smartphones . In IEEE INFOCOM. Heba Aly and Moustafa Youssef. 2016. Zephyr: Ubiquitous accurate multi-sensor fusion-based respiratory rate estimation using smartphones. In IEEE INFOCOM."},{"key":"e_1_3_2_1_3_1","volume-title":"Proceedings of the 2013 ACM international joint conference on Pervasive and ubiquitous computing. 583--586","author":"Islam Aumi Md Tanvir","year":"2013","unstructured":"Md Tanvir Islam Aumi , Sidhant Gupta , Mayank Goel , Eric Larson , and Shwetak Patel . 2013 . DopLink: using the doppler effect for multi-device interaction . In Proceedings of the 2013 ACM international joint conference on Pervasive and ubiquitous computing. 583--586 . Md Tanvir Islam Aumi, Sidhant Gupta, Mayank Goel, Eric Larson, and Shwetak Patel. 2013. DopLink: using the doppler effect for multi-device interaction. In Proceedings of the 2013 ACM international joint conference on Pervasive and ubiquitous computing. 583--586."},{"key":"e_1_3_2_1_4_1","volume-title":"Larry Lynd, Kadria Alasaly, John Swiston, and Js Mark FitzGerald.","author":"Bahadori Katayoun","year":"2009","unstructured":"Katayoun Bahadori , Mary M Doyle-Waters , Carlo Marra , Larry Lynd, Kadria Alasaly, John Swiston, and Js Mark FitzGerald. 2009 . Economic burden of asthma: a systematic review. BMC pulmonary medicine 9, 1 (2009), 24. Katayoun Bahadori, Mary M Doyle-Waters, Carlo Marra, Larry Lynd, Kadria Alasaly, John Swiston, and Js Mark FitzGerald. 2009. Economic burden of asthma: a systematic review. BMC pulmonary medicine 9, 1 (2009), 24."},{"key":"e_1_3_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1109\/BSN.2010.50"},{"key":"e_1_3_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2019.7233"},{"key":"e_1_3_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa042552"},{"key":"e_1_3_2_1_8_1","volume-title":"Usefulness of monitoring lung function in asthma. Archives of disease in childhood 88, 11","author":"Brand PLP","year":"2003","unstructured":"PLP Brand and RJ Roorda . 2003. Usefulness of monitoring lung function in asthma. Archives of disease in childhood 88, 11 ( 2003 ), 1021--1025. PLP Brand and RJ Roorda. 2003. Usefulness of monitoring lung function in asthma. Archives of disease in childhood 88, 11 (2003), 1021--1025."},{"key":"e_1_3_2_1_9_1","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1177\/014107688207500611","article-title":"Chronic upper airway obstruction: value of the flow volume loop examination in assessment and management","volume":"75","author":"Brookes GB","year":"1982","unstructured":"GB Brookes and AJ Fairfax . 1982 . Chronic upper airway obstruction: value of the flow volume loop examination in assessment and management . Journal of the Royal Society of Medicine 75 , 6 (1982), 425 . GB Brookes and AJ Fairfax. 1982. Chronic upper airway obstruction: value of the flow volume loop examination in assessment and management. Journal of the Royal Society of Medicine 75, 6 (1982), 425.","journal-title":"Journal of the Royal Society of Medicine"},{"key":"e_1_3_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1136\/thorax.58.5.375"},{"key":"e_1_3_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1183\/18106838.0503.214"},{"key":"e_1_3_2_1_12_1","volume-title":"Current Clinical Medicine","author":"Carey William D.","unstructured":"William D. Carey . 2010. Current Clinical Medicine 2 nd Edition. Saunders , Cleveland, OH . William D. Carey. 2010. Current Clinical Medicine 2nd Edition. Saunders, Cleveland, OH.","edition":"2"},{"key":"e_1_3_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/PHT.2013.6461305"},{"key":"e_1_3_2_1_14_1","volume-title":"How to develop machine learning models for healthcare. Nature materials 18, 5","author":"Cameron Chen Po-Hsuan","year":"2019","unstructured":"Po-Hsuan Cameron Chen , Yun Liu , and Lily Peng . 2019. How to develop machine learning models for healthcare. Nature materials 18, 5 ( 2019 ), 410. Po-Hsuan Cameron Chen, Yun Liu, and Lily Peng. 2019. How to develop machine learning models for healthcare. Nature materials 18, 5 (2019), 410."},{"key":"e_1_3_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.4108\/icst.pervasivehealth.2013.252148"},{"key":"e_1_3_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.2005.072660"},{"key":"e_1_3_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.02415"},{"key":"e_1_3_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmpt.2016.05.004"},{"key":"e_1_3_2_1_19_1","volume-title":"Quality of spirometry tests performed by 9893 adults in 14 countries: the BOLD Study. Respiratory medicine 105, 10","author":"Enright Paul","year":"2011","unstructured":"Paul Enright , WM Vollmer , B Lamprecht , R Jensen , A Jithoo , W Tan , M Studnicka , P Burney , S Gillespie , and A Sonia Buist . 2011. Quality of spirometry tests performed by 9893 adults in 14 countries: the BOLD Study. Respiratory medicine 105, 10 ( 2011 ), 1507--1515. Paul Enright, WM Vollmer, B Lamprecht, R Jensen, A Jithoo, W Tan, M Studnicka, P Burney, S Gillespie, and A Sonia Buist. 2011. Quality of spirometry tests performed by 9893 adults in 14 countries: the BOLD Study. Respiratory medicine 105, 10 (2011), 1507--1515."},{"key":"e_1_3_2_1_20_1","first-page":"303","article-title":"Quality of spirometry performed by 13,599 participants in the World Trade Center worker and volunteer medical screening program","volume":"55","author":"Enright Paul L","year":"2010","unstructured":"Paul L Enright , Gwen S Skloot , Jean M Cox-Ganser , Iris G Udasin , and Robin Herbert . 2010 . Quality of spirometry performed by 13,599 participants in the World Trade Center worker and volunteer medical screening program . Respiratory Care 55 , 3 (2010), 303 -- 309 . Paul L Enright, Gwen S Skloot, Jean M Cox-Ganser, Iris G Udasin, and Robin Herbert. 2010. Quality of spirometry performed by 13,599 participants in the World Trade Center worker and volunteer medical screening program. Respiratory Care 55, 3 (2010), 303--309.","journal-title":"Respiratory Care"},{"key":"e_1_3_2_1_21_1","unstructured":"National Center for Environmental Health. 2017. Most Recent National Asthma Data. https:\/\/www.cdc.gov\/asthma\/most_recent_national_asthma_data.htm  National Center for Environmental Health. 2017. Most Recent National Asthma Data. https:\/\/www.cdc.gov\/asthma\/most_recent_national_asthma_data.htm"},{"key":"e_1_3_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.39.4.264"},{"key":"e_1_3_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1145\/2858036.2858401"},{"key":"e_1_3_2_1_24_1","volume-title":"Peak expiratory flow in normal subjects. Br Med J 3, 5874","author":"Gregg Ian","year":"1973","unstructured":"Ian Gregg and AJ Nunn . 1973. Peak expiratory flow in normal subjects. Br Med J 3, 5874 ( 1973 ), 282--284. Ian Gregg and AJ Nunn. 1973. Peak expiratory flow in normal subjects. Br Med J 3, 5874 (1973), 282--284."},{"key":"e_1_3_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1145\/2064942.2064944"},{"key":"e_1_3_2_1_26_1","volume-title":"2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05)","author":"Han Ju","year":"2005","unstructured":"Ju Han and Bir Bhanu . 2005 . Human activity recognition in thermal infrared imagery . In 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) -Workshops. IEEE, 17--17. Ju Han and Bir Bhanu. 2005. Human activity recognition in thermal infrared imagery. In 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05)-Workshops. IEEE, 17--17."},{"key":"e_1_3_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1145\/2517351.2517359"},{"key":"e_1_3_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1513\/AnnalsATS.201605-418OC"},{"key":"e_1_3_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.06-2707"},{"key":"e_1_3_2_1_30_1","volume-title":"Gender differences in lung growth. Pediatric pulmonology 19, 2","author":"Hibbert M","year":"1995","unstructured":"M Hibbert , A Lannigan , J Raven , L Landau , and P Phelan . 1995. Gender differences in lung growth. Pediatric pulmonology 19, 2 ( 1995 ), 129--134. M Hibbert, A Lannigan, J Raven, L Landau, and P Phelan. 1995. Gender differences in lung growth. Pediatric pulmonology 19, 2 (1995), 129--134."},{"key":"e_1_3_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1145\/3130924"},{"key":"e_1_3_2_1_32_1","volume-title":"Shake and walk: Acoustic direction finding and fine-grained indoor localization using smartphones","author":"Huang Wenchao","unstructured":"Wenchao Huang , Yan Xiong , Xiang-Yang Li , Hao Lin , Xufei Mao , Panlong Yang , and Yunhao Liu . 2014. Shake and walk: Acoustic direction finding and fine-grained indoor localization using smartphones . In IEEE INFOCOM. 370--378. Wenchao Huang, Yan Xiong, Xiang-Yang Li, Hao Lin, Xufei Mao, Panlong Yang, and Yunhao Liu. 2014. Shake and walk: Acoustic direction finding and fine-grained indoor localization using smartphones. In IEEE INFOCOM. 370--378."},{"key":"e_1_3_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1109\/TCE.2012.6311329"},{"key":"e_1_3_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.02406-2016"},{"key":"e_1_3_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.01655"},{"key":"e_1_3_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.04742"},{"key":"e_1_3_2_1_37_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.52.9.820"},{"key":"e_1_3_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1411532"},{"key":"e_1_3_2_1_39_1","doi-asserted-by":"publisher","DOI":"10.1145\/2370216.2370261"},{"key":"e_1_3_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.2010.01167.x"},{"key":"e_1_3_2_1_41_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICCV.2019.00096"},{"key":"e_1_3_2_1_42_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.130.3.657"},{"key":"e_1_3_2_1_43_1","volume-title":"Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemedicine and e-health 17, 9","author":"Liu Guan-Zheng","year":"2011","unstructured":"Guan-Zheng Liu , Yan-Wei Guo , Qing-Song Zhu , Bang-Yu Huang , and Lei Wang . 2011. Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemedicine and e-health 17, 9 ( 2011 ), 705--711. Guan-Zheng Liu, Yan-Wei Guo, Qing-Song Zhu, Bang-Yu Huang, and Lei Wang. 2011. Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemedicine and e-health 17, 9 (2011), 705--711."},{"key":"e_1_3_2_1_44_1","doi-asserted-by":"publisher","DOI":"10.1145\/2746285.2746303"},{"key":"e_1_3_2_1_45_1","doi-asserted-by":"publisher","DOI":"10.1145\/2973750.2973755"},{"key":"e_1_3_2_1_46_1","first-page":"39","article-title":"Asthma: diagnosis and management","volume":"90","author":"Mathur Sameer K","year":"2006","unstructured":"Sameer K Mathur and William W Busse . 2006 . Asthma: diagnosis and management . Medical Clinics 90 , 1 (2006), 39 -- 60 . Sameer K Mathur and William W Busse. 2006. Asthma: diagnosis and management. Medical Clinics 90, 1 (2006), 39--60.","journal-title":"Medical Clinics"},{"key":"e_1_3_2_1_47_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1513737"},{"key":"e_1_3_2_1_48_1","unstructured":"MicroLife. PF 100 Asthma monitor. https:\/\/www.microlife.com\/consumer-products\/respiratory-care\/asthma-monitor\/pf-100  MicroLife. PF 100 Asthma monitor. https:\/\/www.microlife.com\/consumer-products\/respiratory-care\/asthma-monitor\/pf-100"},{"key":"e_1_3_2_1_49_1","volume-title":"CPM Van der Grinten, P Gustafsson, et al.","author":"Miller Martin R","year":"2005","unstructured":"Martin R Miller , JATS Hankinson , V Brusasco , F Burgos , R Casaburi , A Coates , R Crapo , P vd Enright , CPM Van der Grinten, P Gustafsson, et al. 2005 . Standardisation of spirometry. European respiratory journal 26, 2 (2005), 319--338. Martin R Miller, JATS Hankinson, V Brusasco, F Burgos, R Casaburi, A Coates, R Crapo, P vd Enright, CPM Van der Grinten, P Gustafsson, et al. 2005. Standardisation of spirometry. European respiratory journal 26, 2 (2005), 319--338."},{"key":"e_1_3_2_1_50_1","volume-title":"Design for good acoustics and noise control","author":"Moore John Edwin","unstructured":"John Edwin Moore . 1979. Design for good acoustics and noise control . Macmillan International Higher Education . John Edwin Moore. 1979. Design for good acoustics and noise control. Macmillan International Higher Education."},{"key":"e_1_3_2_1_51_1","volume-title":"Opioid overdose detection using smartphones. Science translational medicine 11, 474","author":"Nandakumar Rajalakshmi","year":"2019","unstructured":"Rajalakshmi Nandakumar , Shyamnath Gollakota , and Jacob E Sunshine . 2019. Opioid overdose detection using smartphones. Science translational medicine 11, 474 ( 2019 ). Rajalakshmi Nandakumar, Shyamnath Gollakota, and Jacob E Sunshine. 2019. Opioid overdose detection using smartphones. Science translational medicine 11, 474 (2019)."},{"key":"e_1_3_2_1_52_1","doi-asserted-by":"publisher","DOI":"10.1145\/2742647.2742674"},{"key":"e_1_3_2_1_53_1","doi-asserted-by":"publisher","DOI":"10.1145\/2858036.2858580"},{"key":"e_1_3_2_1_54_1","unstructured":"Rod Nave. 2000. HyperPhysics. Georgia State University Department of Physics and Astronomy.  Rod Nave. 2000. HyperPhysics. Georgia State University Department of Physics and Astronomy."},{"key":"e_1_3_2_1_55_1","doi-asserted-by":"crossref","unstructured":"Phuc Nguyen Xinyu Zhang Ann Halbower and Tam Vu. 2016. Continuous and fine-grained breathing volume monitoring from afar using wireless signals. In IEEE INFOCOM.  Phuc Nguyen Xinyu Zhang Ann Halbower and Tam Vu. 2016. Continuous and fine-grained breathing volume monitoring from afar using wireless signals. In IEEE INFOCOM.","DOI":"10.1109\/INFOCOM.2016.7524402"},{"key":"e_1_3_2_1_56_1","first-page":"669","article-title":"Chest wall deformities in pediatric surgery","volume":"92","author":"Obermeyer Robert J","year":"2012","unstructured":"Robert J Obermeyer and Michael J Goretsky . 2012 . Chest wall deformities in pediatric surgery . Surgical Clinics 92 , 3 (2012), 669 -- 684 . Robert J Obermeyer and Michael J Goretsky. 2012. Chest wall deformities in pediatric surgery. Surgical Clinics 92, 3 (2012), 669--684.","journal-title":"Surgical Clinics"},{"key":"e_1_3_2_1_57_1","volume-title":"Bayesian regularized neural networks for small n big","author":"Okut Hayrettin","year":"2016","unstructured":"Hayrettin Okut . 2016. Bayesian regularized neural networks for small n big p data. Artificial neural networks-models and applications ( 2016 ). Hayrettin Okut. 2016. Bayesian regularized neural networks for small n big p data. Artificial neural networks-models and applications (2016)."},{"key":"e_1_3_2_1_58_1","doi-asserted-by":"publisher","DOI":"10.1145\/1322263.1322265"},{"key":"e_1_3_2_1_59_1","volume-title":"Acousticcardiogram: Monitoring heartbeats using acoustic signals on smart devices","author":"Qian Kun","year":"2018","unstructured":"Kun Qian , Chenshu Wu , Fu Xiao , Yue Zheng , Yi Zhang , Zheng Yang , and Yunhao Liu . 2018 . Acousticcardiogram: Monitoring heartbeats using acoustic signals on smart devices . In IEEE INFOCOM. 1574--1582. Kun Qian, Chenshu Wu, Fu Xiao, Yue Zheng, Yi Zhang, Zheng Yang, and Yunhao Liu. 2018. Acousticcardiogram: Monitoring heartbeats using acoustic signals on smart devices. In IEEE INFOCOM. 1574--1582."},{"key":"e_1_3_2_1_60_1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00080312"},{"key":"e_1_3_2_1_61_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1843.2012.02251.x"},{"key":"e_1_3_2_1_62_1","volume-title":"Differences between asthma exacerbations and poor asthma control. The Lancet 353, 9150","author":"Reddel Helen","year":"1999","unstructured":"Helen Reddel , Sandra Ware , Guy Marks , Cheryl Salome , Christine Jenkins , and Ann Woolcock . 1999. Differences between asthma exacerbations and poor asthma control. The Lancet 353, 9150 ( 1999 ), 364--369. Helen Reddel, Sandra Ware, Guy Marks, Cheryl Salome, Christine Jenkins, and Ann Woolcock. 1999. Differences between asthma exacerbations and poor asthma control. The Lancet 353, 9150 (1999), 364--369."},{"key":"e_1_3_2_1_63_1","volume-title":"Venkata Nagaraj Kakarparthi, and Kanagaraj Rengaramanujam","author":"Reddy Ravi S","year":"2019","unstructured":"Ravi S Reddy , Khalid A Alahmari , Paul S Silvian , Irshad A Ahmad , Venkata Nagaraj Kakarparthi, and Kanagaraj Rengaramanujam . 2019 . Reliability of chest wall mobility and its correlation with lung functions in healthy nonsmokers, healthy smokers, and patients with COPD. Canadian respiratory journal 2019 (2019). Ravi S Reddy, Khalid A Alahmari, Paul S Silvian, Irshad A Ahmad, Venkata Nagaraj Kakarparthi, and Kanagaraj Rengaramanujam. 2019. Reliability of chest wall mobility and its correlation with lung functions in healthy nonsmokers, healthy smokers, and patients with COPD. Canadian respiratory journal 2019 (2019)."},{"key":"e_1_3_2_1_64_1","unstructured":"Medical International Research. MIR Smart ONE. https:\/\/www.mirsmartone.com\/?page_id=1587&lang=en  Medical International Research. MIR Smart ONE. https:\/\/www.mirsmartone.com\/?page_id=1587&lang=en"},{"key":"e_1_3_2_1_65_1","volume-title":"Tidal","author":"Reyes Bersain A","year":"2016","unstructured":"Bersain A Reyes , Natasa Reljin , Youngsun Kong , Yunyoung Nam , and Ki H Chon . 2016. Tidal volume and instantaneous respiration rate estimation using a volumetric surrogate signal acquired via a smartphone camera. IEEE journal of biomedical and health informatics 21 , 3 ( 2016 ), 764--777. Bersain A Reyes, Natasa Reljin, Youngsun Kong, Yunyoung Nam, and Ki H Chon. 2016. Tidal volume and instantaneous respiration rate estimation using a volumetric surrogate signal acquired via a smartphone camera. IEEE journal of biomedical and health informatics 21, 3 (2016), 764--777."},{"key":"e_1_3_2_1_66_1","doi-asserted-by":"publisher","DOI":"10.1145\/3241539.3241568"},{"key":"e_1_3_2_1_67_1","doi-asserted-by":"publisher","DOI":"10.1145\/3264947"},{"key":"e_1_3_2_1_68_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eswa.2013.04.013"},{"key":"e_1_3_2_1_69_1","doi-asserted-by":"publisher","DOI":"10.1097\/JOM.0b013e31821aa964"},{"key":"e_1_3_2_1_70_1","doi-asserted-by":"publisher","DOI":"10.1145\/3210240.3210312"},{"key":"e_1_3_2_1_71_1","doi-asserted-by":"publisher","DOI":"10.1145\/3290605.3300248"},{"key":"e_1_3_2_1_72_1","doi-asserted-by":"publisher","DOI":"10.1145\/3300061.3345453"},{"key":"e_1_3_2_1_73_1","volume-title":"Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking. 82--94","author":"Wang Wei","year":"2016","unstructured":"Wei Wang , Alex X Liu , and Ke Sun . 2016 . Device-free gesture tracking using acoustic signals . In Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking. 82--94 . Wei Wang, Alex X Liu, and Ke Sun. 2016. Device-free gesture tracking using acoustic signals. In Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking. 82--94."},{"key":"e_1_3_2_1_74_1","volume-title":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2371--2374","author":"Yu Meng-Chieh","year":"2012","unstructured":"Meng-Chieh Yu , Jia-Ling Liou , Shuenn-Wen Kuo , Ming-Sui Lee , and Yi-Ping Hung . 2012 . Noncontact respiratory measurement of volume change using depth camera . In Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2371--2374 . Meng-Chieh Yu, Jia-Ling Liou, Shuenn-Wen Kuo, Ming-Sui Lee, and Yi-Ping Hung. 2012. Noncontact respiratory measurement of volume change using depth camera. In Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2371--2374."},{"key":"e_1_3_2_1_75_1","doi-asserted-by":"publisher","DOI":"10.1145\/3214289"},{"key":"e_1_3_2_1_76_1","doi-asserted-by":"publisher","DOI":"10.1145\/2742647.2742662"},{"key":"e_1_3_2_1_77_1","doi-asserted-by":"publisher","DOI":"10.1145\/3081333.3081356"},{"key":"e_1_3_2_1_78_1","volume-title":"Forced expiratory parameters in healthy preschool children (3--6 years of age). Pediatric pulmonology 35, 3","author":"Zapletal A","year":"2003","unstructured":"A Zapletal and J Chalupova . 2003. Forced expiratory parameters in healthy preschool children (3--6 years of age). Pediatric pulmonology 35, 3 ( 2003 ), 200--207. A Zapletal and J Chalupova. 2003. Forced expiratory parameters in healthy preschool children (3--6 years of age). Pediatric pulmonology 35, 3 (2003), 200--207."},{"key":"e_1_3_2_1_79_1","doi-asserted-by":"publisher","DOI":"10.1145\/3300061.3300125"},{"key":"e_1_3_2_1_80_1","doi-asserted-by":"publisher","DOI":"10.1145\/3241539.3241570"}],"event":{"name":"MobiCom '20: The 26th Annual International Conference on Mobile Computing and Networking","location":"London United Kingdom","acronym":"MobiCom '20","sponsor":["SIGMOBILE ACM Special Interest Group on Mobility of Systems, Users, Data and Computing"]},"container-title":["Proceedings of the 26th Annual International Conference on Mobile Computing and Networking"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3372224.3419209","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3372224.3419209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T17:32:10Z","timestamp":1750181530000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3372224.3419209"}},"subtitle":["monitoring human lung function via acoustic sensing on commodity smartphones"],"short-title":[],"issued":{"date-parts":[[2020,9,18]]},"references-count":80,"alternative-id":["10.1145\/3372224.3419209","10.1145\/3372224"],"URL":"https:\/\/doi.org\/10.1145\/3372224.3419209","relation":{},"subject":[],"published":{"date-parts":[[2020,9,18]]},"assertion":[{"value":"2020-09-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}