{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:24:08Z","timestamp":1750220648675,"version":"3.41.0"},"reference-count":9,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2019,11,14]],"date-time":"2019-11-14T00:00:00Z","timestamp":1573689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["GetMobile: Mobile Comp. and Comm."],"published-print":{"date-parts":[[2019,11,14]]},"abstract":"<jats:p>Monitoring blood pressure serves as a significant indicator for assessing a person's health. In particular, blood volume and arterial blood pressure as the conjunction of arterial resistance and cardiac output represent a critical signal in the evaluation of a person's cardiovascular system. While in-clinic blood pressure monitoring remains the cornerstone of hypertension management, at-home monitoring can give a more complete picture of heart health and can potentially detect masked hypertension, which is only evident outside the clinic [6].<\/jats:p>","DOI":"10.1145\/3372300.3372306","type":"journal-article","created":{"date-parts":[[2019,11,14]],"date-time":"2019-11-14T22:07:36Z","timestamp":1573769256000},"page":"25-29","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Continuous and Passive Blood Pressure Monitoring Throughout the Day and Night"],"prefix":"10.1145","volume":"23","author":[{"given":"Christian","family":"Holz","sequence":"first","affiliation":[{"name":"Microsoft Research, Redmond, WA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2019,11,14]]},"reference":[{"key":"e_1_2_1_1_1","first-page":"3","article-title":")","volume":"2","author":"Carek Andrew","year":"2018","journal-title":"Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1145\/3053330"},{"key":"e_1_2_1_3_1","first-page":"3","article-title":")","volume":"1","author":"Holz Christian","year":"2017","journal-title":"Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."},{"key":"e_1_2_1_4_1","first-page":"6","volume":"62","author":"O'Brien Eoin","year":"2013","journal-title":"Hypertension"},{"key":"e_1_2_1_5_1","doi-asserted-by":"crossref","unstructured":"Eoin O'Brien Roland Asmar Lawrence Beilin Yutaka Imai Giuseppe Mancia Thomas Mengden Martin Myers Paul Padfield Paolo Palatini Gianfranco Parati Thomas Pickering Josep Redon Jan Staessen George Stergiou and Paolo Verdecchia. \"Practice Guidelines of the European Society of Hypertension for Clinic Ambulatory and Self Blood Pressure Measurement.\" 23 (05 2005) 697--701.  Eoin O'Brien Roland Asmar Lawrence Beilin Yutaka Imai Giuseppe Mancia Thomas Mengden Martin Myers Paul Padfield Paolo Palatini Gianfranco Parati Thomas Pickering Josep Redon Jan Staessen George Stergiou and Paolo Verdecchia. \"Practice Guidelines of the European Society of Hypertension for Clinic Ambulatory and Self Blood Pressure Measurement.\" 23 (05 2005) 697--701.","DOI":"10.1097\/01.hjh.0000163132.84890.c4"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.110.160911"},{"key":"e_1_2_1_7_1","doi-asserted-by":"crossref","unstructured":"Stephanie L.-O. Martin Andrew M. Carek Chang-Sei Kim Hazar Ashouri Omer Inan Jin-Oh Hahn Ramakrishna Mukkamala. Weighing scale-based pulse transit time is a superior marker of blood pressure than conventional pulse arrival time. (2016). Scientific Reports 6 (12).  Stephanie L.-O. Martin Andrew M. Carek Chang-Sei Kim Hazar Ashouri Omer Inan Jin-Oh Hahn Ramakrishna Mukkamala. Weighing scale-based pulse transit time is a superior marker of blood pressure than conventional pulse arrival time. (2016). Scientific Reports 6 (12).","DOI":"10.1038\/srep39273"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.111.00217"},{"key":"e_1_2_1_9_1","unstructured":"Centers for Disease Control and Prevention. High Blood Pressure Fact Sheet. https:\/\/www. cdc.gov\/dhdsp\/data_statistics\/fact_sheets\/ fs_bloodpressure.htm  Centers for Disease Control and Prevention. High Blood Pressure Fact Sheet. https:\/\/www. cdc.gov\/dhdsp\/data_statistics\/fact_sheets\/ fs_bloodpressure.htm"}],"container-title":["GetMobile: Mobile Computing and Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3372300.3372306","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3372300.3372306","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T22:02:20Z","timestamp":1750197740000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3372300.3372306"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,14]]},"references-count":9,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,11,14]]}},"alternative-id":["10.1145\/3372300.3372306"],"URL":"https:\/\/doi.org\/10.1145\/3372300.3372306","relation":{},"ISSN":["2375-0529","2375-0537"],"issn-type":[{"type":"print","value":"2375-0529"},{"type":"electronic","value":"2375-0537"}],"subject":[],"published":{"date-parts":[[2019,11,14]]},"assertion":[{"value":"2019-11-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}