{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:26:30Z","timestamp":1750220790632,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":12,"publisher":"ACM","license":[{"start":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T00:00:00Z","timestamp":1575590400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,12,6]]},"DOI":"10.1145\/3386415.3386959","type":"proceedings-article","created":{"date-parts":[[2020,5,31]],"date-time":"2020-05-31T04:22:36Z","timestamp":1590898956000},"page":"1-4","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["New Method of Stator Ground Protection for Generators Connected as Expanding Unit"],"prefix":"10.1145","author":[{"given":"He","family":"Wang","sequence":"first","affiliation":[{"name":"Changsha University of Science and Technology, Changsha Hunan China"}]},{"given":"Zhigang","family":"Wang","sequence":"additional","affiliation":[{"name":"Changsha University of Science and Technology, Changsha Hunan China"}]},{"given":"Zhao","family":"Liu","sequence":"additional","affiliation":[{"name":"Hunan College of Information, Changsha Hunan China"}]}],"member":"320","published-online":{"date-parts":[[2020,5,30]]},"reference":[{"issue":"11","key":"e_1_3_2_1_1_1","first-page":"39","article-title":"Protection scheme based on the fault transient component of zero-sequence voltage under the stator ground fault of generators[J]","volume":"23","author":"BI","year":"2003","unstructured":"BI Da-qiang, WANG Xiang-heng, GUI Lin , Protection scheme based on the fault transient component of zero-sequence voltage under the stator ground fault of generators[J] . Proceedings of the CSEE , 2003 , 23 ( 11 ): 39 -- 44 . BI Da-qiang, WANG Xiang-heng, GUI Lin, et al. Protection scheme based on the fault transient component of zero-sequence voltage under the stator ground fault of generators[J]. Proceedings of the CSEE, 2003, 23(11): 39--44.","journal-title":"Proceedings of the CSEE"},{"issue":"13","key":"e_1_3_2_1_2_1","first-page":"45","article-title":"Protection scheme based on fault transient component of third harmonic voltage for stator ground fault of generators [J]","volume":"27","author":"BI","year":"2003","unstructured":"BI Da-qiang, WANG Xiang-heng, WANG Wei-jian . Protection scheme based on fault transient component of third harmonic voltage for stator ground fault of generators [J] . Automation of Electric Power Systems , 2003 , 27 ( 13 ): 45 -- 49 . BI Da-qiang, WANG Xiang-heng, WANG Wei-jian. Protection scheme based on fault transient component of third harmonic voltage for stator ground fault of generators [J]. Automation of Electric Power Systems, 2003, 27(13): 45--49.","journal-title":"Automation of Electric Power Systems"},{"issue":"1","key":"e_1_3_2_1_3_1","first-page":"59","article-title":"Reason and countermeasures of maloperation of generator stator ground protection based on the third harmonic[J]","volume":"25","author":"TANG","year":"2001","unstructured":"TANG Qing-di, TAN Jian-hua . Reason and countermeasures of maloperation of generator stator ground protection based on the third harmonic[J] . Automation of Electric Power Systems , 2001 , 25 ( 1 ): 59 -- 61 . TANG Qing-di, TAN Jian-hua. Reason and countermeasures of maloperation of generator stator ground protection based on the third harmonic[J]. Automation of Electric Power Systems, 2001, 25(1): 59--61.","journal-title":"Automation of Electric Power Systems"},{"issue":"16","key":"e_1_3_2_1_4_1","first-page":"51","article-title":"Adjustment and operation of injection voltage scheme against the stator single-phase-to-ground fault of large generators[J]","volume":"32","author":"LI","year":"2004","unstructured":"LI De-jia, BI Da-qiang, WANG Wei-jian . Adjustment and operation of injection voltage scheme against the stator single-phase-to-ground fault of large generators[J] . Relay , 2004 , 32 ( 16 ): 51 -- 56 . LI De-jia, BI Da-qiang, WANG Wei-jian. Adjustment and operation of injection voltage scheme against the stator single-phase-to-ground fault of large generators[J]. Relay, 2004, 32(16): 51--56.","journal-title":"Relay"},{"issue":"6","key":"e_1_3_2_1_5_1","first-page":"15","article-title":"Analysis and application of injection voltage scheme against generator stator ground faults [J]","volume":"28","author":"TAI","year":"2000","unstructured":"TAI Neng-ling, YIN Xiang-gen, HU Yu-feng, Analysis and application of injection voltage scheme against generator stator ground faults [J] . Relay , 2000 , 28 ( 6 ): 15 -- 18 . TAI Neng-ling, YIN Xiang-gen, HU Yu-feng, et al. Analysis and application of injection voltage scheme against generator stator ground faults [J]. Relay, 2000, 28(6): 15--18.","journal-title":"Relay"},{"issue":"12","key":"e_1_3_2_1_6_1","first-page":"27","article-title":"Influencing factors of stator ground-fault protection with outside sources[J]","volume":"33","author":"HOU","year":"2005","unstructured":"HOU You-tao, ZHANG Li-li . Influencing factors of stator ground-fault protection with outside sources[J] . Relay , 2005 , 33 ( 12 ): 27 -- 31 . HOU You-tao, ZHANG Li-li. Influencing factors of stator ground-fault protection with outside sources[J]. Relay, 2005, 33(12): 27--31.","journal-title":"Relay"},{"issue":"11","key":"e_1_3_2_1_7_1","first-page":"103","article-title":"Field application and analysis of the stator earth fault protection with voltage injection for large-sized generator [J]","volume":"31","author":"ZHANG","year":"2007","unstructured":"ZHANG Qi-xue, XI Kang-qing, CHEN Jia-sheng, Field application and analysis of the stator earth fault protection with voltage injection for large-sized generator [J] . Automation of Electric Power Systems , 2007 , 31 ( 11 ): 103 -- 107 . ZHANG Qi-xue, XI Kang-qing, CHEN Jia-sheng, et al. Field application and analysis of the stator earth fault protection with voltage injection for large-sized generator [J]. Automation of Electric Power Systems, 2007, 31(11): 103--107.","journal-title":"Automation of Electric Power Systems"},{"key":"e_1_3_2_1_8_1","volume-title":"Principle and application of electric power equipment protection[M]","author":"Weijian Wang","year":"2002","unstructured":"Wang Weijian . Principle and application of electric power equipment protection[M] . Beijing : China Power Press , 2002 : 223--224 (in Chinese). Wang Weijian. Principle and application of electric power equipment protection[M]. Beijing:China Power Press, 2002: 223--224 (in Chinese)."},{"issue":"22","key":"e_1_3_2_1_9_1","first-page":"10","article-title":"Discussion on single-phase earth protection of generator stator in small-and-medium-sized hydropower station[J]","volume":"33","author":"Daqing Mu","year":"2005","unstructured":"Mu Daqing , Yin Xianggen . Discussion on single-phase earth protection of generator stator in small-and-medium-sized hydropower station[J] . Relay , 2005 , 33 ( 22 ): 10 -- 15 (in Chinese). Mu Daqing, Yin Xianggen. Discussion on single-phase earth protection of generator stator in small-and-medium-sized hydropower station[J]. Relay, 2005, 33(22): 10--15 (in Chinese).","journal-title":"Relay"},{"issue":"11","key":"e_1_3_2_1_10_1","first-page":"12","article-title":"generator stator ground fault protection scheme with selectivity[J]","volume":"24","author":"Nengling Tai","year":"2004","unstructured":"Tai Nengling , Wu Hongxiao . New wavelet-based 100% generator stator ground fault protection scheme with selectivity[J] . Proceedings of the CSEE , 2004 , 24 ( 11 ): 12 -- 16 (in Chinese). Tai Nengling, Wu Hongxiao. New wavelet-based 100% generator stator ground fault protection scheme with selectivity[J]. Proceedings of the CSEE, 2004, 24(11): 12--16 (in Chinese).","journal-title":"Proceedings of the CSEE"},{"issue":"13","key":"e_1_3_2_1_11_1","first-page":"89","article-title":"A leakage current based selective single-phase grounding fault protection scheme for stator winding of hydro generator[J]","volume":"32","author":"Yuanyuan Wang","year":"2008","unstructured":"Wang Yuanyuan , Zeng Xiangjun , Long Lihong , A leakage current based selective single-phase grounding fault protection scheme for stator winding of hydro generator[J] . Power System Technology , 2008 , 32 ( 13 ): 89 -- 93 (in Chinese). Wang Yuanyuan, Zeng Xiangjun, Long Lihong, et al.A leakage current based selective single-phase grounding fault protection scheme for stator winding of hydro generator[J]. Power System Technology, 2008, 32(13): 89--93 (in Chinese).","journal-title":"Power System Technology"},{"issue":"5","key":"e_1_3_2_1_12_1","first-page":"34","article-title":"Selective protection for stator winding grounding faults[J]","volume":"28","author":"Xiangjun Zeng","year":"2008","unstructured":"Zeng Xiangjun , Wang Yuanyuan , Long Lihong , Selective protection for stator winding grounding faults[J] . Electric Power Automation Equipment , 2008 , 28 ( 5 ): 34 -- 37 (in Chinese). Zeng Xiangjun, Wang Yuanyuan, Long Lihong, et al. Selective protection for stator winding grounding faults[J]. Electric Power Automation Equipment, 2008, 28(5): 34--37 (in Chinese).","journal-title":"Electric Power Automation Equipment"}],"event":{"name":"ICITEE-2019: 2nd International Conference on Information Technologies and Electrical Engineering","acronym":"ICITEE-2019","location":"Zhuzhou Hunan China"},"container-title":["Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3386415.3386959","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3386415.3386959","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T22:41:45Z","timestamp":1750200105000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3386415.3386959"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,6]]},"references-count":12,"alternative-id":["10.1145\/3386415.3386959","10.1145\/3386415"],"URL":"https:\/\/doi.org\/10.1145\/3386415.3386959","relation":{},"subject":[],"published":{"date-parts":[[2019,12,6]]},"assertion":[{"value":"2020-05-30","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}