{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:28:23Z","timestamp":1750220903757,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":20,"publisher":"ACM","license":[{"start":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T00:00:00Z","timestamp":1575590400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,12,6]]},"DOI":"10.1145\/3386415.3387022","type":"proceedings-article","created":{"date-parts":[[2020,5,31]],"date-time":"2020-05-31T04:22:36Z","timestamp":1590898956000},"page":"1-4","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["The Partial Discharge Diagnosis and Location of C-GIS Cable Joint Based on Multiple Detection Method"],"prefix":"10.1145","author":[{"given":"Jin","family":"He","sequence":"first","affiliation":[{"name":"State grid tianjin electric power research institute, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuyan","family":"Man","sequence":"additional","affiliation":[{"name":"State grid Tianjin electric power company, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liming","family":"Zhang","sequence":"additional","affiliation":[{"name":"State grid Tianjin electric power company, Tianjin, Chinaliming"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Chen","sequence":"additional","affiliation":[{"name":"State grid tianjin electric power research institute, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wang","sequence":"additional","affiliation":[{"name":"State grid Tianjin electric power research institute, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Cao","sequence":"additional","affiliation":[{"name":"State grid Tianjin electric power company, Tianjin, Chinachunhui"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2020,5,30]]},"reference":[{"key":"e_1_3_2_1_1_1","volume-title":"SF6 gas insulated fully enclosed composite apparatus[M]","author":"Xuechen LUO","year":"1998","unstructured":"LUO Xuechen , SF6 gas insulated fully enclosed composite apparatus[M] . Beijing : China Electric Power Press , 1998 , 11. LUO Xuechen, SF6 gas insulated fully enclosed composite apparatus[M]. Beijing: China Electric Power Press, 1998, 11."},{"key":"e_1_3_2_1_2_1","volume-title":"GIS device and its insulation technology [M]","author":"Yuchang QIU","year":"1994","unstructured":"QIU Yuchang . GIS device and its insulation technology [M] . Beijing : Water Conservancy and power press, 1994 , 6. QIU Yuchang. GIS device and its insulation technology [M]. Beijing: Water Conservancy and power press, 1994, 6."},{"key":"e_1_3_2_1_3_1","volume-title":"High voltage insulation technology [M]","author":"Zhang YAN","year":"2001","unstructured":"YAN Zhang , Zhu Deheng . High voltage insulation technology [M] . Beijing : China Electric Power Press , 2001 . YAN Zhang, Zhu Deheng. High voltage insulation technology [M]. Beijing: China Electric Power Press, 2001."},{"key":"e_1_3_2_1_4_1","first-page":"89","article-title":"Analysis of the characteristics of SF6 inflatable switcher[J]","volume":"11","author":"Changgeng LI","year":"2017","unstructured":"LI Changgeng , LIU Qiangxing . Analysis of the characteristics of SF6 inflatable switcher[J] . Electric Engineering , 2017 , 11 (A): 89 -- 91 . LI Changgeng, LIU Qiangxing. Analysis of the characteristics of SF6 inflatable switcher[J]. Electric Engineering, 2017, 11(A): 89--91.","journal-title":"Electric Engineering"},{"key":"e_1_3_2_1_5_1","first-page":"63","article-title":"Comprehensive comparison of 35kV inflatable switchgear and HGIS equipment[J]","volume":"27","author":"Fengfang HUANG","year":"2017","unstructured":"HUANG Fengfang . Comprehensive comparison of 35kV inflatable switchgear and HGIS equipment[J] . Mechanical and Electrical Information , 2017 , 27 : 63 . HUANG Fengfang. Comprehensive comparison of 35kV inflatable switchgear and HGIS equipment[J]. Mechanical and Electrical Information, 2017, 27:63.","journal-title":"Mechanical and Electrical Information"},{"key":"e_1_3_2_1_6_1","first-page":"31","article-title":"Medium voltage switchgear and its development[J]","volume":"7","author":"Jianji LI","year":"2012","unstructured":"LI Jianji . Medium voltage switchgear and its development[J] . Electrical Manufacturing , 2012 , 7 : 31 -- 35 . LI Jianji. Medium voltage switchgear and its development[J]. Electrical Manufacturing, 2012, 7: 31--35.","journal-title":"Electrical Manufacturing"},{"key":"e_1_3_2_1_7_1","volume-title":"Liu Ming, et al. Electrified detection technology of power grid equipment [M].","author":"Jiang PENG","year":"2014","unstructured":"PENG Jiang , program , Liu Ming, et al. Electrified detection technology of power grid equipment [M]. Beijing : China Power Press , 2014 , 12. PENG Jiang, program, Liu Ming, et al. Electrified detection technology of power grid equipment [M]. Beijing: China Power Press, 2014, 12."},{"key":"e_1_3_2_1_8_1","volume-title":"Training materials of power grid equipment state detection technology [M]","author":"Jun LV","year":"2015","unstructured":"LV Jun , Peng Jiangji , Xiao Tong , Training materials of power grid equipment state detection technology [M] . Beijing : China Power Press , 2015 , 5. LV Jun, Peng Jiangji, Xiao Tong, et al. Training materials of power grid equipment state detection technology [M]. Beijing: China Power Press, 2015, 5."},{"key":"e_1_3_2_1_9_1","volume-title":"High Voltage Apparatus","author":"Zhumao LU","year":"2017","unstructured":"LU Zhumao , LIU Qing , WANG Tianzheng , Comprehensive application and research of multi live detection methods in partial discharge diagnosis for GIS[J] . High Voltage Apparatus , 2017 , 10: 222--226. LU Zhumao, LIU Qing, WANG Tianzheng, et al. Comprehensive application and research of multi live detection methods in partial discharge diagnosis for GIS[J]. High Voltage Apparatus, 2017, 10: 222--226."},{"key":"e_1_3_2_1_10_1","volume-title":"High Voltage Apparatus","author":"Yongxiang LI","year":"2017","unstructured":"LI Yongxiang , WANG Tianzheng , JIN Tao , Detection and analysis of high voltage switchgear internal partial discharge based on multiple detection technology[J] . High Voltage Apparatus , 2017 , 1: 45--50. LI Yongxiang, WANG Tianzheng, JIN Tao, et al. Detection and analysis of high voltage switchgear internal partial discharge based on multiple detection technology[J]. High Voltage Apparatus, 2017, 1: 45--50."},{"issue":"1","key":"e_1_3_2_1_11_1","first-page":"117","article-title":"Partial discharge simulation analysis and frequency-dependent model for 110kV three-phase cross-bonded cable[J]","volume":"31","author":"Wei WANG","year":"2011","unstructured":"WANG Wei , WANG Yongliang , LIU Chong , Partial discharge simulation analysis and frequency-dependent model for 110kV three-phase cross-bonded cable[J] . Proceedings of the CSEE , 2011 , 31 ( 1 ): 117 -- 122 . WANG Wei, WANG Yongliang, LIU Chong, et al. Partial discharge simulation analysis and frequency-dependent model for 110kV three-phase cross-bonded cable[J]. Proceedings of the CSEE, 2011, 31(1): 117--122.","journal-title":"Proceedings of the CSEE"},{"key":"e_1_3_2_1_12_1","first-page":"226","article-title":"The partial discharge detection and location as well as dissection of 110kV XLPE cable terminal[J]","volume":"33","author":"Xu CHENG","year":"2013","unstructured":"CHENG Xu , TAO Shiyang , WANG Wenshan . The partial discharge detection and location as well as dissection of 110kV XLPE cable terminal[J] . Proceeding of the CSEE , 2013 , 33 : 226 -- 230 . CHENG Xu, TAO Shiyang, WANG Wenshan. The partial discharge detection and location as well as dissection of 110kV XLPE cable terminal[J]. Proceeding of the CSEE, 2013, 33: 226--230.","journal-title":"Proceeding of the CSEE"},{"issue":"21","key":"e_1_3_2_1_13_1","first-page":"154","article-title":"study of cross-shaped ultrasonic array sensor applied to partial discharge location in transformers[J]","volume":"33","author":"Xiaohu XIN","year":"2013","unstructured":"XIN Xiaohu , LI Jisheng , JI Haiying , study of cross-shaped ultrasonic array sensor applied to partial discharge location in transformers[J] . Proceedings of the CSEE , 2013 , 33 ( 21 ): 154 -- 162 . XIN Xiaohu, LI Jisheng, JI Haiying, et al. study of cross-shaped ultrasonic array sensor applied to partial discharge location in transformers[J]. Proceedings of the CSEE, 2013, 33(21): 154--162.","journal-title":"Proceedings of the CSEE"},{"issue":"12","key":"e_1_3_2_1_14_1","first-page":"42","article-title":"Study on detection of partial discharge in xlpe cable at higher frequency[J]","volume":"25","author":"Junhua LUO","year":"2001","unstructured":"LUO Junhua . Study on detection of partial discharge in xlpe cable at higher frequency[J] . Power System Technology , 2001 , 25 ( 12 ): 42 -- 45 . LUO Junhua. Study on detection of partial discharge in xlpe cable at higher frequency[J]. Power System Technology, 2001, 25(12): 42--45.","journal-title":"Power System Technology"},{"key":"e_1_3_2_1_15_1","volume-title":"High Voltage Engineering","author":"Junhua LIU","year":"2009","unstructured":"LIU Junhua , YAO Ming , HUANG Chenjun , Experimental research on partical discharge location in GIS using ultrasonic associated with electromagnetic wave method[J] . High Voltage Engineering , 2009 , 10: 2458--2463. LIU Junhua, YAO Ming, HUANG Chenjun, et al. Experimental research on partical discharge location in GIS using ultrasonic associated with electromagnetic wave method[J]. High Voltage Engineering, 2009, 10: 2458--2463."},{"key":"e_1_3_2_1_16_1","first-page":"98","article-title":"Analysis on application case of GIS partial discharge ultra-high frequency time-of-arrival location[J]","volume":"8","author":"Defeng YOU","year":"2018","unstructured":"YOU Defeng , LI Xingwang , PANG Xiaofeng , Analysis on application case of GIS partial discharge ultra-high frequency time-of-arrival location[J] . Guangdong Electric Power , 2018 , 8 , 27(8): 98 -- 101 . YOU Defeng, LI Xingwang, PANG Xiaofeng, Analysis on application case of GIS partial discharge ultra-high frequency time-of-arrival location[J]. Guangdong Electric Power, 2018, 8, 27(8): 98--101.","journal-title":"Guangdong Electric Power"},{"key":"e_1_3_2_1_17_1","volume-title":"High Voltage Apparatus","author":"Lin XING","year":"2011","unstructured":"XING Lin , YAO Chenguo , SUN Caixin . Method of time difference reading on frequency domain for PD location in GIS[J] . High Voltage Apparatus , 2011 , 47(6): 13--2. XING Lin, YAO Chenguo, SUN Caixin. Method of time difference reading on frequency domain for PD location in GIS[J]. High Voltage Apparatus, 2011, 47(6): 13--2."},{"key":"e_1_3_2_1_18_1","volume-title":"High Voltage Engineering","author":"Junhua LIU","year":"2009","unstructured":"LIU Junhua , GUO Chanxin , YAO Ming , Analysis on the propagation routes of electromagnetic waves of partial discharge in GIS[J] . High Voltage Engineering , 2009 , 5: 1044--1048. LIU Junhua, GUO Chanxin, YAO Ming, et al. Analysis on the propagation routes of electromagnetic waves of partial discharge in GIS[J]. High Voltage Engineering, 2009, 5: 1044--1048."},{"issue":"21","key":"e_1_3_2_1_19_1","first-page":"77","article-title":"A partial dis-charge location method based on the characteristics of the electromagnetic wave propagation route in GIS[J]","volume":"32","author":"Junhua LIU","year":"2008","unstructured":"LIU Junhua , YAO Ming , WANG Jiang , A partial dis-charge location method based on the characteristics of the electromagnetic wave propagation route in GIS[J] . Automation of Electric Power Systems , 2008 , 32 ( 21 ): 77 -- 81 . LIU Junhua, YAO Ming, WANG Jiang, et al. A partial dis-charge location method based on the characteristics of the electromagnetic wave propagation route in GIS[J]. Automation of Electric Power Systems, 2008, 32(21): 77--81.","journal-title":"Automation of Electric Power Systems"},{"key":"e_1_3_2_1_20_1","volume-title":"Wang naiqing. Partial discharge and test technology of electrical equipment [M]","author":"Changrong Qiu","year":"1994","unstructured":"Qiu Changrong , Wang naiqing. Partial discharge and test technology of electrical equipment [M] . China Machine Press , 1994 , 9. Qiu Changrong, Wang naiqing. Partial discharge and test technology of electrical equipment [M]. China Machine Press, 1994, 9."}],"event":{"name":"ICITEE-2019: 2nd International Conference on Information Technologies and Electrical Engineering","acronym":"ICITEE-2019","location":"Zhuzhou Hunan China"},"container-title":["Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3386415.3387022","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3386415.3387022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T23:44:48Z","timestamp":1750203888000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3386415.3387022"}},"subtitle":["High Voltage and Insulation Technology"],"short-title":[],"issued":{"date-parts":[[2019,12,6]]},"references-count":20,"alternative-id":["10.1145\/3386415.3387022","10.1145\/3386415"],"URL":"https:\/\/doi.org\/10.1145\/3386415.3387022","relation":{},"subject":[],"published":{"date-parts":[[2019,12,6]]},"assertion":[{"value":"2020-05-30","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}