{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:24:42Z","timestamp":1750220682674,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":7,"publisher":"ACM","license":[{"start":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T00:00:00Z","timestamp":1606953600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,12,3]]},"DOI":"10.1145\/3452940.3452978","type":"proceedings-article","created":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T15:28:54Z","timestamp":1621265334000},"page":"197-201","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Calculation of Electric Field Distribution and Minimum Discharge Distance in Micro Environment of High Voltage Switchgear"],"prefix":"10.1145","author":[{"given":"Tao","family":"Tian","sequence":"first","affiliation":[{"name":"State Grid Tianjin Electric Power, Company Ninghe Power Supply, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haibin","family":"Wang","sequence":"additional","affiliation":[{"name":"State Grid Tianjin Electric Power, Company Ninghe Power Supply, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianye","family":"Hou","sequence":"additional","affiliation":[{"name":"State Grid Tianjin Electric Power, Company Ninghe Power Supply, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liming","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Grid Tianjin Electric Power Company, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baikuan","family":"Zhou","sequence":"additional","affiliation":[{"name":"State Grid Tianjin Electric Power, Company Ninghe Power Supply, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huiyu","family":"Li","sequence":"additional","affiliation":[{"name":"State Grid Tianjin Electric Power, Company Ninghe Power Supply, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2021,5,17]]},"reference":[{"key":"e_1_3_2_1_1_1","volume-title":"Heb Electric Power","author":"Xianhai P","year":"2017","unstructured":"Xianhai P , Lipeng J , Hao J , Causes Analysis on 40.5 kV High voltage Switchgear Panel Insulation Fault and Measures[J] . Heb Electric Power , 2017 . Xianhai P, Lipeng J, Hao J, et al. Causes Analysis on 40.5 kV High voltage Switchgear Panel Insulation Fault and Measures[J]. Heb Electric Power, 2017."},{"key":"e_1_3_2_1_2_1","volume-title":"Technological Development of Enterprise","author":"Yun H.","year":"2017","unstructured":"Yun H. Analysis of Insulation Mode and Insulation Standard of Medium Voltage Switchgear[J] . Technological Development of Enterprise , 2017 . Yun H. Analysis of Insulation Mode and Insulation Standard of Medium Voltage Switchgear[J]. Technological Development of Enterprise, 2017."},{"key":"e_1_3_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2016.7736828"},{"key":"e_1_3_2_1_4_1","volume-title":"High Voltage Apparatus","author":"Liu Y","year":"2017","unstructured":"Liu Y , Guo Q. Numerical Calculation of Temperature and Humidity Fields in Cable Room of High-voltage Switchgearr[J] . High Voltage Apparatus , 2017 , 53(9): 6--10 and 16. Liu Y, Guo Q. Numerical Calculation of Temperature and Humidity Fields in Cable Room of High-voltage Switchgearr[J]. High Voltage Apparatus, 2017, 53(9):6--10 and 16."},{"key":"e_1_3_2_1_5_1","volume-title":"High Voltage Engineering","author":"Cheng X","year":"2015","unstructured":"Cheng X , Han S , He Z , Structure design of the chamber for 40.5 kV environment-friendly cubicle gas insulated switchgear[J] . High Voltage Engineering , 2015 , 41(8): 2772--2779. Cheng X, Han S, He Z, et al. Structure design of the chamber for 40.5 kV environment-friendly cubicle gas insulated switchgear[J]. High Voltage Engineering, 2015, 41(8):2772--2779."},{"key":"e_1_3_2_1_6_1","volume-title":"Gaoya Dianqi\/High Voltage Apparatus","author":"Zhang K","year":"2018","unstructured":"Zhang K , Chen L , Huang L. Simulation Study on Temperature Field of Solid Insulated Switchgear Based on Finite Element Method[J] . Gaoya Dianqi\/High Voltage Apparatus , 2018 , 54(12): 76--81. Zhang K, Chen L, Huang L. Simulation Study on Temperature Field of Solid Insulated Switchgear Based on Finite Element Method[J]. Gaoya Dianqi\/High Voltage Apparatus, 2018, 54(12):76--81."},{"key":"e_1_3_2_1_7_1","volume-title":"High Voltage Engineering","author":"Zhang Yaru","year":"2017","unstructured":"Zhang Yaru , Wang Yong, Huang Qingdan , et al. Effect of Humidity on Dielectric Properties of Air [J] . High Voltage Engineering , 2017 , 35(8): 2464--2471. Zhang Yaru, Wang Yong, Huang Qingdan, et al. Effect of Humidity on Dielectric Properties of Air [J]. High Voltage Engineering, 2017, 35(8):2464--2471."}],"event":{"name":"ICITEE2020: The 3rd International Conference on Information Technologies and Electrical Engineering","acronym":"ICITEE2020","location":"Changde City Hunan China"},"container-title":["Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3452940.3452978","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3452940.3452978","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T22:03:26Z","timestamp":1750197806000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3452940.3452978"}},"subtitle":["High Voltage and Insulation Technology"],"short-title":[],"issued":{"date-parts":[[2020,12,3]]},"references-count":7,"alternative-id":["10.1145\/3452940.3452978","10.1145\/3452940"],"URL":"https:\/\/doi.org\/10.1145\/3452940.3452978","relation":{},"subject":[],"published":{"date-parts":[[2020,12,3]]},"assertion":[{"value":"2021-05-17","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}