{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:31:33Z","timestamp":1777336293584,"version":"3.51.4"},"reference-count":64,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T00:00:00Z","timestamp":1646265600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"DOI":"10.13039\/100012774","name":"Innovation fund Denmark","doi-asserted-by":"crossref","award":["6153-00009B"],"award-info":[{"award-number":["6153-00009B"]}],"id":[{"id":"10.13039\/100012774","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100023338","name":"Copenhagen Center for Health Technology","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100023338","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Comput. Healthcare"],"published-print":{"date-parts":[[2022,4,30]]},"abstract":"<jats:p>\n            This article presents the design, technical implementation, and feasibility evaluation of\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            \u2014a context-aware, mobile\n            <jats:bold>electrocardiogram<\/jats:bold>\n            (ECG) collection system for longitudinal arrhythmia screening under free-living conditions. Along with ECG,\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            also records active and passive contextual data, including patient-reported symptoms and physical activity. This contextual data can provide a more accurate understanding of what happens before, during, and after an arrhythmia event, thereby providing additional information in the diagnosis of arrhythmia. By using a plugin-based architecture for ECG and contextual sensing,\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            is device-agnostic and can integrate with various wireless ECG devices and supports cross-platform deployment. We deployed the\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            system in a feasibility study involving 24 patients who used the system over a two-week period. During the study, we observed high patient acceptance and compliance with a satisfactory yield of collected ECG and contextual data. The results demonstrate the high usability and feasibility of\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            for longitudinal ambulatory monitoring under free-living conditions. The article also reports from two clinical cases, which demonstrate how a cardiologist can utilize the collected contextual data to improve the accuracy of arrhythmia analysis. Finally, the article discusses the lessons learned and the challenges found in the\n            <jats:bold>\n              <jats:italic>mCardia<\/jats:italic>\n            <\/jats:bold>\n            design and the feasibility study.\n          <\/jats:p>","DOI":"10.1145\/3494581","type":"journal-article","created":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T19:31:12Z","timestamp":1646335872000},"page":"1-28","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":12,"title":["mCardia: A Context-Aware ECG Collection System for Ambulatory Arrhythmia Screening"],"prefix":"10.1145","volume":"3","author":[{"given":"Devender","family":"Kumar","sequence":"first","affiliation":[{"name":"Department of Health Technology, Technical University of Denmark, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raju","family":"Maharjan","sequence":"additional","affiliation":[{"name":"Department of Health Technology, Technical University of Denmark, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alban","family":"Maxhuni","sequence":"additional","affiliation":[{"name":"Department of Health Technology, Technical University of Denmark, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helena","family":"Dominguez","sequence":"additional","affiliation":[{"name":"Bispebjerg-Frederiksberg Hospital, Department of Cardiology, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne","family":"Fr\u00f8lich","sequence":"additional","affiliation":[{"name":"Department of Public Health, University of Copenhagen, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakob E.","family":"Bardram","sequence":"additional","affiliation":[{"name":"Department of Health Technology, Technical University of Denmark, Copenhagen, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2022,3,3]]},"reference":[{"key":"e_1_3_3_2_2","unstructured":"AliveCor. 2020. AliveCor Inc. Retrieved July 8 2020 fromhttps:\/\/www.alivecor.com\/kardiamobile."},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2006.02.002"},{"key":"e_1_3_3_4_2","volume-title":"Blueprints Cardiology","author":"Awtry Eric","year":"2006","unstructured":"Eric Awtry, Cathy Jeon, and Molly G Ware. 2006. Blueprints Cardiology. Lippincott Williams & Wilkins."},{"key":"e_1_3_3_5_2","unstructured":"Sarah Bachis and J\u00f6rg Ottenbacher. 2017. Validity of EcgMove R-peak Detection. Retrieved May 31 2021 fromhttps:\/\/www.movisens.com\/wp-content\/downloads\/WPekgMove_Validity_of_R_peak.pdf."},{"key":"e_1_3_3_6_2","unstructured":"Jakob E. Bardram. 2019. CACHET Unified Method for Assessment of Clinical Feasibility. Retrieved May 2 2020 fromhttps:\/\/www.cachet.dk\/research\/cumacf."},{"key":"e_1_3_3_7_2","unstructured":"Jakob E. Bardram. 2019. REAFEL: Reaching the Frail Elderly Patient for optimizing diagnosis of atrial fibrillation. Retrieved May 2 2020 fromhttps:\/\/www.cachet.dk\/research\/research_projects\/reafel."},{"key":"e_1_3_3_8_2","unstructured":"Jakob E. Bardram. 2020. The CARP Mobile Sensing Framework \u2013 A Cross-platform Reactive Programming Framework and Runtime Environment for Digital Phenotyping. CoRR abs\/2006.11904. https:\/\/arxiv.org\/abs\/2006.11904."},{"key":"e_1_3_3_9_2","unstructured":"Jakob E. Bardram. 2020. CARP Mobile Sensing Framework in Flutter. Retrieved June 23 2020 fromhttps:\/\/pub.dev\/packages\/carp_mobile_sensing."},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/MPRV.2020.2989880"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1145\/1540373.1540391"},{"issue":"10","key":"e_1_3_3_12_2","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1161\/01.CIR.98.10.946","article-title":"Impact of atrial fibrillation on the risk of death: The Framingham Heart Study","volume":"98","author":"Benjamin Emelia J.","year":"1998","unstructured":"Emelia J. Benjamin, Philip A. Wolf, Ralph B. D\u2019Agostino, Halit Silbershatz, William B. Kannel, and Daniel Levy. 1998. Impact of atrial fibrillation on the risk of death: The Framingham Heart Study. Circulation 98, 10 (1998), 946\u2013952.","journal-title":"Circulation"},{"issue":"9","key":"e_1_3_3_13_2","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.amjmed.2004.06.024","article-title":"Misdiagnosis of atrial fibrillation and its clinical consequences","volume":"117","author":"Bogun Frank","year":"2004","unstructured":"Frank Bogun, Daejoon Anh, Gautham Kalahasty, Erik Wissner, Chadi Bou Serhal, Rabih Bazzi, W. Douglas Weaver, and Claudio Schuger. 2004. Misdiagnosis of atrial fibrillation and its clinical consequences. The American Journal of Medicine 117, 9 (2004), 636\u2013642.","journal-title":"The American Journal of Medicine"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.116.003428"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.005119"},{"issue":"2","key":"e_1_3_3_16_2","first-page":"23","article-title":"Computer-aided arrhythmia diagnosis with bio-signal processing: A survey of trends and techniques","volume":"52","author":"Dinakarrao Sai Manoj Pudukotai","year":"2019","unstructured":"Sai Manoj Pudukotai Dinakarrao, Axel Jantsch, and Muhammad Shafique. 2019. Computer-aided arrhythmia diagnosis with bio-signal processing: A survey of trends and techniques. ACM Computing Surveys 52, 2 (2019), 23.","journal-title":"ACM Computing Surveys"},{"issue":"2","key":"e_1_3_3_17_2","first-page":"199","article-title":"The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation","volume":"5","author":"D\u00f6rr Marcus","year":"2019","unstructured":"Marcus D\u00f6rr, Vivien Nohturfft, No\u00e9 Brasier, Emil Bosshard, Aleksandar Djurdjevic, Stefan Gross, Christina J. Raichle, Mattias Rhinisperger, Raphael St\u00f6ckli, and Jens Eckstein. 2019. The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation. JACC: Clinical Electrophysiology 5, 2 (2019), 199\u2013208.","journal-title":"JACC: Clinical Electrophysiology"},{"key":"e_1_3_3_18_2","first-page":"277","volume-title":"Proceedings of the Computing in Cardiology 2013","author":"Forkan Abdur","year":"2013","unstructured":"Abdur Forkan, Ibrahim Khalil, and Zahir Tari. 2013. Context-aware cardiac monitoring for early detection of heart diseases. In Proceedings of the Computing in Cardiology 2013. IEEE, 277\u2013280."},{"key":"e_1_3_3_19_2","first-page":"369","volume-title":"Proceedings of the 2016 Computing in Cardiology Conference","author":"Forkan Abdur Rahim Mohamad","year":"2016","unstructured":"Abdur Rahim Mohamad Forkan and Weichich Hu. 2016. A context-aware, predictive and protective approach for wellness monitoring of cardiac patients. In Proceedings of the 2016 Computing in Cardiology Conference. IEEE, 369\u2013372."},{"issue":"3","key":"e_1_3_3_20_2","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/0002-9149(94)90363-8","article-title":"Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study)","volume":"74","author":"Furberg Curt D.","year":"1994","unstructured":"Curt D. Furberg, Bruce M. Psaty, Teri A. Manolio, Julius M. Gardin, Vivienne E. Smith, Pentti M. Rautaharju, and CHS Collaborative Research Group. 1994. Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study). The American Journal of Cardiology 74, 3 (1994), 236\u2013241.","journal-title":"The American Journal of Cardiology"},{"issue":"3","key":"e_1_3_3_21_2","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1093\/europace\/euq503","article-title":"Effectiveness of remote monitoring in the management of syncope and palpitations","volume":"13","author":"Furukawa Toshiyuki","year":"2011","unstructured":"Toshiyuki Furukawa, Roberto Maggi, Cristina Bertolone, Fabrizio Ammirati, Massimo Santini, Renato Ricci, Franco Giada, and Michele Brignole. 2011. Effectiveness of remote monitoring in the management of syncope and palpitations. Europace 13, 3 (2011), 431\u2013437.","journal-title":"Europace"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.15420\/AER.2016.17.2"},{"issue":"4","key":"e_1_3_3_23_2","doi-asserted-by":"crossref","first-page":"e86","DOI":"10.2196\/jmir.4067","article-title":"The eHealth enhanced chronic care model: A theory derivation approach","volume":"17","author":"Gee Perry M.","year":"2015","unstructured":"Perry M. Gee, Deborah A. Greenwood, Debora A. Paterniti, Deborah Ward, and Lisa M. Soederberg Miller. 2015. The eHealth enhanced chronic care model: A theory derivation approach. Journal of Medical Internet Research 17, 4 (2015), e86.","journal-title":"Journal of Medical Internet Research"},{"issue":"6","key":"e_1_3_3_24_2","doi-asserted-by":"crossref","first-page":"e13641","DOI":"10.2196\/13641","article-title":"Accuracy of mHealth devices for atrial fibrillation screening: Systematic review","volume":"7","author":"Giebel Godwin Denk","year":"2019","unstructured":"Godwin Denk Giebel and Christian Gissel. 2019. Accuracy of mHealth devices for atrial fibrillation screening: Systematic review. JMIR mHealth and uHealth 7, 6 (2019), e13641.","journal-title":"JMIR mHealth and uHealth"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1080\/01449290310001624329"},{"issue":"1","key":"e_1_3_3_26_2","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/1471-2261-4-13","article-title":"Arrhythmia-provoking factors and symptoms at the onset of paroxysmal atrial fibrillation: A study based on interviews with 100 patients seeking hospital assistance","volume":"4","author":"Hansson Anders","year":"2004","unstructured":"Anders Hansson, Bjarne Madsen-H\u00e4rdig, and S. Bertil Olsson. 2004. Arrhythmia-provoking factors and symptoms at the onset of paroxysmal atrial fibrillation: A study based on interviews with 100 patients seeking hospital assistance. BMC Cardiovascular Disorders 4, 1 (2004), 13.","journal-title":"BMC Cardiovascular Disorders"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.115.017288"},{"issue":"2","key":"e_1_3_3_28_2","first-page":"141","article-title":"Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation results of the XPECT trial","volume":"3","author":"Hindricks Gerhard","year":"2010","unstructured":"Gerhard Hindricks, Evgueny Pokushalov, Lubos Urban, Milos Taborsky, Karl-Heinz Kuck, Dmitry Lebedev, Guido Rieger, and Helmut P\u00fcrerfellner. 2010. Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation results of the XPECT trial. Circulation: Arrhythmia and Electrophysiology 3, 2 (2010), 141\u2013147.","journal-title":"Circulation: Arrhythmia and Electrophysiology"},{"key":"e_1_3_3_29_2","unstructured":"Barnab\u00e1s Homola and Jakob E. Bardram. 2019. Research Package \u2013 A Flutter Framework for mHealth Research. Retrieved June 23 2020 fromhttps:\/\/www.researchpackage.org."},{"key":"e_1_3_3_30_2","unstructured":"Apple Inc.2020. Taking an ECG with the ECG app on Apple Watch Series 4 or later. Retrieved July 8 2020 fromhttps:\/\/support.apple.com\/en-us\/HT208955."},{"key":"e_1_3_3_31_2","unstructured":"Inc iRhythm Technologies. 2020. Zio- The Flexible Patient-Friendly Accurate Cardiac Monitor. Retrieved Jan 6 2020 fromhttps:\/\/www.irhythmtech.com\/professionals\/why-zio."},{"key":"e_1_3_3_32_2","doi-asserted-by":"crossref","unstructured":"Nino Isakadze and Seth S. Martin. 2019. How useful is the smartwatch ECG? Trends in Cardiovascular Medicine 30 7 (2020) 442\u2013448.","DOI":"10.1016\/j.tcm.2019.10.010"},{"issue":"2","key":"e_1_3_3_33_2","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ipej.2019.12.013","article-title":"Comparison of arrhythmia detection by conventional Holter and a novel ambulatory ECG system using patch and Android App, over 24 h period","volume":"20","author":"Karunadas Chakkalakkal Prabhakaran","year":"2020","unstructured":"Chakkalakkal Prabhakaran Karunadas and Cibu Mathew. 2020. Comparison of arrhythmia detection by conventional Holter and a novel ambulatory ECG system using patch and Android App, over 24 h period. Indian Pacing and Electrophysiology Journal 20, 2 (2020), 49\u201353.","journal-title":"Indian Pacing and Electrophysiology Journal"},{"issue":"11","key":"e_1_3_3_34_2","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1093\/europace\/eum191","article-title":"Outcome parameters for trials in atrial fibrillation: Recommendations from a consensus conference organized by the German Atrial Fibrillation Competence NETwork and the European Heart Rhythm Association","volume":"9","author":"Kirchhof Paulus","year":"2007","unstructured":"Paulus Kirchhof, Angelo Auricchio, Jeroen Bax, Harry Crijns, John Camm, Hans-Christoph Diener, Andreas Goette, Gerd Hindricks, Stefan Hohnloser, Lukas Kappenberger, K. H. Kuck, G. Y. Lip, B. Olsson, T. Meinertz, S. Priori, U. Ravens, G. Steinbeck, E. Svernhage, J. Tijssen, A. Vincent, and G. Breithardt. 2007. Outcome parameters for trials in atrial fibrillation: Recommendations from a consensus conference organized by the German Atrial Fibrillation Competence NETwork and the European Heart Rhythm Association. Europace 9, 11 (2007), 1006\u20131023.","journal-title":"Europace"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1145\/1978942.1979396"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.1145\/3422158"},{"key":"e_1_3_3_37_2","unstructured":"Devender Kumar Thomas Nilson and Jakob E. Bardram. 2020. CARP Movisens Sampling Package. Retrieved June 23 2020 fromhttps:\/\/pub.dev\/packages\/carp_movisens_package."},{"key":"e_1_3_3_38_2","unstructured":"Devender Kumar Thomas Nilson and Jakob E. Bardram. 2020. Movisens Flutter Plugin. Retrieved June 23 2020 fromhttps:\/\/pub.dev\/packages\/movisens_flutter."},{"key":"e_1_3_3_39_2","volume-title":"Applying UML and Patterns: An Introduction to Object Oriented Analysis and Design and Interative Development","author":"Larman Craig","year":"2012","unstructured":"Craig Larman. 2012. Applying UML and Patterns: An Introduction to Object Oriented Analysis and Design and Interative Development. Pearson Education India."},{"key":"e_1_3_3_40_2","first-page":"1259","volume-title":"Proceedings of the Human Factors and Ergonomics Society Annual Meeting","volume":"36","author":"Lewis James R.","year":"1992","unstructured":"James R. Lewis. 1992. Psychometric evaluation of the post-study system usability questionnaire: The PSSUQ. In Proceedings of the Human Factors and Ergonomics Society Annual Meeting, Vol. 36. SAGE Publications Sage CA: Los Angeles, CA, 1259\u20131260."},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1145\/3344256"},{"key":"e_1_3_3_42_2","first-page":"1222","volume-title":"Proceedings of the 4th European Conference of the International Federation for Medical and Biological Engineering","author":"Li Jin Peng","year":"2009","unstructured":"Jin Peng Li, Damon Berry, and Richard Hayes. 2009. A mobile ECG monitoring system with context collection. In Proceedings of the 4th European Conference of the International Federation for Medical and Biological Engineering. Springer, 1222\u20131225."},{"key":"e_1_3_3_43_2","unstructured":"Gadgeon Smart Systems Pvt. Ltd.2020. WebCardio- A wireless disposable leadless multi day Holter monitor. Retrieved Jan 6 2020 fromhttps:\/\/webcardio.in\/."},{"key":"e_1_3_3_44_2","first-page":"1","volume-title":"Proceedings of the 2011 5th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth)","author":"Marcu Gabriela","year":"2011","unstructured":"Gabriela Marcu, Jakob E. Bardram, and Silvia Gabrielli. 2011. A framework for overcoming challenges in designing persuasive monitoring and feedback systems for mental illness. In Proceedings of the 2011 5th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth). IEEE, 1\u20138."},{"issue":"2","key":"e_1_3_3_45_2","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/S0002-8703(02)00065-0","article-title":"Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring","volume":"144","author":"M\u00e1rquez Manlio F.","year":"2002","unstructured":"Manlio F. M\u00e1rquez, Luis Col\u00edn, Milton Guevara, Pedro Iturralde, and Antonio G. Hermosillo. 2002. Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring. American Heart Journal 144, 2 (2002), 187\u2013197.","journal-title":"American Heart Journal"},{"key":"e_1_3_3_46_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMsa022615"},{"key":"e_1_3_3_47_2","article-title":"Prevalence of undiagnosed atrial fibrillation in elderly individuals and potential cost-effectiveness of non-invasive ambulatory electrocardiographic screening: The ASSERT-III study","author":"McIntyre W. F.","year":"2019","unstructured":"W. F. McIntyre, Jean Hai Ein Yong, R. K. Sandhu, D. J. Gladstone, K. Simek, Y. Y. Liu, F. R. Quinn, R. Tytus, D. Zizzo, S. Henein, N. Ivers, and J. S. Healey. 2019. Prevalence of undiagnosed atrial fibrillation in elderly individuals and potential cost-effectiveness of non-invasive ambulatory electrocardiographic screening: The ASSERT-III study. Journal of Electrocardiology 58 (2019), 56\u201360.","journal-title":"Journal of Electrocardiology"},{"key":"e_1_3_3_48_2","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.jelectrocard.2019.11.040","article-title":"Prevalence of undiagnosed atrial fibrillation in elderly individuals and potential cost-effectiveness of non-invasive ambulatory electrocardiographic screening: The ASSERT-III study","volume":"58","author":"McIntyre W. F.","year":"2020","unstructured":"W. F. McIntyre, Jean Hai Ein Yong, R. K. Sandhu, D. J. Gladstone, K. Simek, Y. Y. Liu, F. R. Quinn, R. Tytus, D. Zizzo, S. Henein, et\u00a0al. 2020. Prevalence of undiagnosed atrial fibrillation in elderly individuals and potential cost-effectiveness of non-invasive ambulatory electrocardiographic screening: The ASSERT-III study. Journal of electrocardiology 58 (2020), 56\u201360.","journal-title":"Journal of electrocardiology"},{"key":"e_1_3_3_49_2","doi-asserted-by":"publisher","DOI":"10.3390\/s150511465"},{"key":"e_1_3_3_50_2","doi-asserted-by":"publisher","DOI":"10.1186\/1748-5908-6-42"},{"key":"e_1_3_3_51_2","unstructured":"World Health Organization. 2017. Case study: Type 1 diabetes. Retrieved Aug 8 2019 fromhttps:\/\/www.who.int\/news-room\/fact-sheets\/detail\/cardiovascular-diseases-(cvds)."},{"key":"e_1_3_3_52_2","first-page":"1","volume-title":"Proceedings of the 2014 IEEE International Symposium on Medical Measurements and Applications","author":"Quesnel Patrick X.","year":"2014","unstructured":"Patrick X. Quesnel, Adrian D. C. Chan, and Homer Yang. 2014. Signal quality and false myocardial ischemia alarms in ambulatory electrocardiograms. In Proceedings of the 2014 IEEE International Symposium on Medical Measurements and Applications. IEEE, 1\u20135."},{"key":"e_1_3_3_53_2","doi-asserted-by":"publisher","DOI":"10.21037\/atm.2019.06.79"},{"issue":"04","key":"e_1_3_3_54_2","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1055\/s-0038-1672138","article-title":"Factors influencing sustained engagement with ECG self-monitoring: Perspectives from patients and health care providers","volume":"9","author":"Reading Meghan","year":"2018","unstructured":"Meghan Reading, Dawon Baik, Melissa Beauchemin, Kathleen T. Hickey, and Jacqueline A. Merrill. 2018. Factors influencing sustained engagement with ECG self-monitoring: Perspectives from patients and health care providers. Applied Clinical Informatics 9, 04 (2018), 772\u2013781.","journal-title":"Applied Clinical Informatics"},{"key":"e_1_3_3_55_2","volume-title":"Proceedings of Ubicomp","author":"Shirazi Alireza Sahami","year":"2007","unstructured":"Alireza Sahami Shirazi, Diana Cheng, Oliver Kroell, Dagmar Kern, and Albrecht Schmidt. 2007. CardioViz: Contextual capture and visualization for long-term ecg data. In Proceedings of Ubicomp."},{"issue":"2","key":"e_1_3_3_56_2","doi-asserted-by":"crossref","first-page":"024001","DOI":"10.1115\/1.4042795","article-title":"A systematic review of noninvasive electrocardiogram monitoring devices for the evaluation of suspected cardiovascular syncope","volume":"13","author":"Solbiati Monica","year":"2019","unstructured":"Monica Solbiati, Lucia Trombetta, Roberto M. Sacco, Luca Erba, Viviana Bozzano, Giorgio Costantino, Satish R. Raj, Franca Barbic, Giovanni Casazza, Franca Dipaola, Raffaello Furlan, Rose A. Kenny, James V. Quinn, Robert S. Sheldon, Win-Kuang Shen, Benjamin C. Sun, Venkatesh Thiruganasambandamoorthy, and Matthew J. Reed. 2019. A systematic review of noninvasive electrocardiogram monitoring devices for the evaluation of suspected cardiovascular syncope. Journal of Medical Devices 13, 2 (2019), 024001.","journal-title":"Journal of Medical Devices"},{"key":"e_1_3_3_57_2","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1109\/CIC.2008.4749212","volume-title":"Proceedings of the 2008 Computers in Cardiology","author":"Spadini F.","year":"2008","unstructured":"F. Spadini, F. Vergari, L. Nachman, C. Lamberti, and T. Salmon Cinotti. 2008. A wireless and context-aware ECG monitor: An iMote2 based portable system. In Proceedings of the 2008 Computers in Cardiology. IEEE, 997\u20131000."},{"key":"e_1_3_3_58_2","unstructured":"Zenicor Medical Systems. 2020. The Zenicor solution. Retrieved July 8 2020 fromhttps:\/\/zenicor.com\/zenicor-ekg\/."},{"issue":"1","key":"e_1_3_3_59_2","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1007\/s40258-013-0070-9","article-title":"Economic burden and disparities in healthcare resource use among adult patients with cardiac arrhythmia","volume":"12","author":"Tang Derek H.","year":"2014","unstructured":"Derek H. Tang, Adrienne M. Gilligan, and Klaus Romero. 2014. Economic burden and disparities in healthcare resource use among adult patients with cardiac arrhythmia. Applied Health Economics and Health Policy 12, 1 (2014), 59\u201371.","journal-title":"Applied Health Economics and Health Policy"},{"key":"e_1_3_3_60_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098214005283748"},{"key":"e_1_3_3_61_2","doi-asserted-by":"publisher","DOI":"10.2307\/30036540"},{"key":"e_1_3_3_62_2","doi-asserted-by":"publisher","DOI":"10.4022\/jafib.2078"},{"issue":"1","key":"e_1_3_3_63_2","article-title":"Chronic disease management: What will it take to improve care for chronic illness?","volume":"1","author":"Wagner Edward H.","year":"1998","unstructured":"Edward H. Wagner. 1998. Chronic disease management: What will it take to improve care for chronic illness? Effective Clinical Practice 1, 1 (1998).","journal-title":"Effective Clinical Practice"},{"issue":"7","key":"e_1_3_3_64_2","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1161\/CIRCULATIONAHA.114.009024","article-title":"Novel wireless devices for cardiac monitoring","volume":"130","author":"III Joseph A. Walsh","year":"2014","unstructured":"Joseph A. Walsh III, Eric J. Topol, and Steven R. Steinhubl. 2014. Novel wireless devices for cardiac monitoring. Circulation 130, 7 (2014), 573\u2013581.","journal-title":"Circulation"},{"key":"e_1_3_3_65_2","doi-asserted-by":"publisher","DOI":"10.1145\/3173574.3174058"}],"container-title":["ACM Transactions on Computing for Healthcare"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3494581","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3494581","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T19:31:16Z","timestamp":1750188676000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3494581"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,3]]},"references-count":64,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,4,30]]}},"alternative-id":["10.1145\/3494581"],"URL":"https:\/\/doi.org\/10.1145\/3494581","relation":{},"ISSN":["2691-1957","2637-8051"],"issn-type":[{"value":"2691-1957","type":"print"},{"value":"2637-8051","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,3]]},"assertion":[{"value":"2020-09-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-10-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-03-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}