{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T04:15:02Z","timestamp":1750220102834,"version":"3.41.0"},"publisher-location":"New York, NY, USA","reference-count":7,"publisher":"ACM","license":[{"start":{"date-parts":[[2022,6,24]],"date-time":"2022-06-24T00:00:00Z","timestamp":1656028800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,6,24]]},"DOI":"10.1145\/3548608.3559259","type":"proceedings-article","created":{"date-parts":[[2022,10,14]],"date-time":"2022-10-14T17:47:01Z","timestamp":1665769621000},"page":"539-543","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A contact pressure detection method of isolation switch based on Fiber Bragg Grating"],"prefix":"10.1145","author":[{"given":"Zhen","family":"Meng","sequence":"first","affiliation":[{"name":"Jinzhou Power Supply Branch, State Grid Liaoning Electric Power Co., LTD, China"}]},{"given":"Peng","family":"Qiu","sequence":"additional","affiliation":[{"name":"Jinzhou Power Supply Branch, State Grid Liaoning Electric Power Co., LTD, China"}]},{"given":"Yueming","family":"Pan","sequence":"additional","affiliation":[{"name":"Jinzhou Power Supply Branch, State Grid Liaoning Electric Power Co., LTD, China"}]}],"member":"320","published-online":{"date-parts":[[2022,10,14]]},"reference":[{"issue":"11","key":"e_1_3_2_1_1_1","first-page":"111","volume":"27","author":"LIANG","year":"2020","unstructured":"LIANG Binbin, ZENG Zhihuan. Analysis and Treatment of Common Faults of High Voltage Disconnector[ J] . Technology and Market , 2020 , 27 ( 11 ): 111 - 112 . LIANG Binbin, ZENG Zhihuan. Analysis and Treatment of Common Faults of High Voltage Disconnector[J]. Technology and Market, 2020, 27(11): 111-112.","journal-title":"Technology and Market"},{"key":"e_1_3_2_1_2_1","volume-title":"Insulation Defect Detection Method for Disconnecting Switches Based on Time-frequency Analysis of 3D Electric Fields[J]. High Voltage Engineering","author":"CHENG","year":"2020","unstructured":"CHENG Lin, ZHANG Hongye, YI Tongqiang , Insulation Defect Detection Method for Disconnecting Switches Based on Time-frequency Analysis of 3D Electric Fields[J]. High Voltage Engineering , 2020 , 46(4): 1417-1423. CHENG Lin, ZHANG Hongye, YI Tongqiang, Insulation Defect Detection Method for Disconnecting Switches Based on Time-frequency Analysis of 3D Electric Fields[J]. High Voltage Engineering, 2020, 46(4): 1417-1423."},{"key":"e_1_3_2_1_3_1","volume-title":"Review on breaking-closing position monitoring method for intelligent disconnecting switches[C]\/\/IOP Conference Series:Earth and Environmental Science. [S.l.]:IOP","author":"BOZHONG W","year":"2019","unstructured":"BOZHONG W , WENQI M , YIZHOU J , Review on breaking-closing position monitoring method for intelligent disconnecting switches[C]\/\/IOP Conference Series:Earth and Environmental Science. [S.l.]:IOP , 2019 : 012026. BOZHONG W, WENQI M, YIZHOU J, et al. Review on breaking-closing position monitoring method for intelligent disconnecting switches[C]\/\/IOP Conference Series:Earth and Environmental Science. [S.l.]:IOP, 2019:012026."},{"key":"e_1_3_2_1_4_1","volume-title":"Data Augmentation Method for Disconnecting Switch Images and Its Application in Automatic State Recognition[J]. High Voltage Engineering","author":"LIU","year":"2020","unstructured":"LIU Ziquan, WANG Huifang, GUAN Minyuan , Data Augmentation Method for Disconnecting Switch Images and Its Application in Automatic State Recognition[J]. High Voltage Engineering , 2020 ,46(2): 441-447.. LIU Ziquan, WANG Huifang, GUAN Minyuan, Data Augmentation Method for Disconnecting Switch Images and Its Application in Automatic State Recognition[J]. High Voltage Engineering, 2020,46(2): 441-447.."},{"issue":"22","key":"e_1_3_2_1_5_1","first-page":"39","article-title":"Application of High-Voltage Isolating Switch Opening and Closing System Based on Attitude Sensor[J]","volume":"532","author":"ZHU","year":"2020","unstructured":"ZHU Xiaowei . Application of High-Voltage Isolating Switch Opening and Closing System Based on Attitude Sensor[J] . Electric Engineering , 2020 , 532 ( 22 ): 39 - 41 . ZHU Xiaowei. Application of High-Voltage Isolating Switch Opening and Closing System Based on Attitude Sensor[J]. Electric Engineering, 2020, 532(22): 39-41.","journal-title":"Electric Engineering"},{"key":"e_1_3_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2015.2403305"},{"key":"e_1_3_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.5008491"}],"event":{"name":"ICCIR 2022: 2022 2nd International Conference on Control and Intelligent Robot","acronym":"ICCIR 2022","location":"Nanjing China"},"container-title":["Proceedings of the 2022 2nd International Conference on Control and Intelligent Robotics"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3548608.3559259","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3548608.3559259","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T18:10:22Z","timestamp":1750183822000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3548608.3559259"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,24]]},"references-count":7,"alternative-id":["10.1145\/3548608.3559259","10.1145\/3548608"],"URL":"https:\/\/doi.org\/10.1145\/3548608.3559259","relation":{},"subject":[],"published":{"date-parts":[[2022,6,24]]},"assertion":[{"value":"2022-10-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}